HTechMT CO600N2H Coating Thickness Gauge High temperature probe eddy Current 5000μm
HTechMT Thickness Gauge probe CO600N2H is a high temperature probe that can measure 250 ℃, the thickness measurement range is 5000 μm, the accuracy is +/- 1% or 2.5 μm, the minimum headroom height is 80mm, the test radius is 5mm, and the minimum substrate thickness is 0.8mm. CO600N2H is an ordinary eddy Current thickness measurement probe.
HTechMT-
KAIRDA F1 standard probe magnetic Induction NDT530 Coating Thickness Gauge optional probe
$ 173.00 -
Defelsko PosiTector 6000 FN3 metal thickness Measurement Instrument
$ 1756.00 -
Qnix Fe/NFe3mm Dual Function Thickness Probe for magnetic Induction and eddy Current 3000μm
$ 1059.00 -
IPRE CT400 magnetic Induction eddy Current Coating Thickness Gauge Measurement range 0~1500μm
$ 254.00 -
Defelsko PosiTector 6000 FKS1 Coating Thickness Gauge for coatings
$ 1150.00
The Thickness Gauge probe core is made of super wear-resistant materials, which greatly improves the service life of the probe and ensures the measurement accuracy and repeatability of the instrument. This design reverses the common defects in the market, such as inaccurate measurement due to core wear, or falling off the inlaid rubera.
Probe number

Executive Standards:ISO 2178/2360/2808、ISO 19840、ASTM B244/B499/D1186/D1400
Probe selection
| shape | Probe model | A | B | C | Range | Accuracy 1 | Minimum headroom | Minimum test radius | Minimum substrate thickness |
![]() | CO600F1S | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 80mm | 5mm | 0.8mm |
| CO600F2S | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 80mm | 5mm | 0.8mm | |
| CO600F5S | 9 | 40 | 50 | 0.5mm | ± 1-3% or 2.0μm | 80mm | 5mm | 0.8mm | |
| CO600F1H | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 80mm | 5mm | 0.8mm | |
| CO600F2H | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 80mm | 5mm | 0.8mm | |
| CO600N1S | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 80mm | 5mm | 0.3mm | |
| CO600N2S | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 80mm | 5mm | 0.3mm | |
| CO600N5S | 9 | 40 | 50 | 0.5mm | ± 1-3% or 2.0μm | 80mm | 5mm | 0.3mm | |
![]() | CO600F1R | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 30mm | 5mm | 0.8mm |
| CO600F2R | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 30mm | 5mm | 0.8mm | |
| CO600N1R | 9 | 40 | 50 | 1.5mm | ± 1-3% or 2.5μm | 30mm | 5mm | 0.3mm | |
| CO600N2R | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 30mm | 5mm | 0.3mm | |
![]() | CO600F3S | 16.5 | 40 | 50 | 13.0mm | ± 1-3% or 50μm | 80mm | 10mm | 1.0mm |
| CO600F4S | 24 | 60 | 50 | 26.0mm | ± 1-3% or 100μm | 120mm | 30mm | 1.0mm |
*High temperature probe temperature is 250°C
HTechMT CO600N2H Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Eddy Current |
| Measurement range | 5000μm |
| margin of error | ±1~3%/±20μm |
| thinnest substrate | 0.8mm |
| Test environment | Nonmagnetic metal substrate |
| probe | Ordinary probe |
| Minimum headroom | 80mm |
| Minimum measurement surface | R5mm |
| Probe contact surface diameter | 9mm |
| Probe contact temperature | Up to 250 ℃ |
HTechMT CO600N2H Coating Thickness Gauge Packing list
host X1, AA battery X2, test piece set X1, zero adjustment plate X1, certificate X1, manual X1, silicone protective cover X1, instrument bag (cloth bag) X1.
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


CO600N2H