HTechMT CO600N2R Coating Thickness Gauge probe eddy current right angle 5000μm
HTechMT Thickness Gauge probe CO600N2R is a 90 degree right angle probe, using eddy Current thickness measurement principle, the range is 5000 μm, the accuracy is +/- 1~ 3% or 20 μm, the contact surface diameter of CO600N2R is 9mm, and the minimum headroom height is 30mm.
HTechMT-
Linshang LS221 Coating Thickness Gauge Fe/NFe 2000μm
$ 247.00 -
Germany EPK MikroTest NiFe50 McCourt Eletroplating Nickel Thickness Gauge, Thickness Measurement: 0~50μm
$ 2443.00 -
Defelsko F0S split 0 ° probe 1150 μm/+/- 1% for small parts, edge coating measurements
$ 1025.00 -
Qnix Fe/NFe5mm Dual Function Thickness Probe magnetic Induction and eddy Current 5000 μm
$ 1479.00 -
YIBAI CTG-600 Coating Thickness Gauge dual-use Film Thickness Gauge
$ 284.00
The Thickness Gauge probe core is made of super wear-resistant materials, which greatly improves the service life of the probe and ensures the measurement accuracy and repeatability of the instrument. This design reverses the common defects in the market, such as inaccurate measurement due to core wear, or falling off the inlaid rubera.
Probe number

Executive Standards:ISO 2178/2360/2808、ISO 19840、ASTM B244/B499/D1186/D1400
Probe selection
| shape | Probe model | A | B | C | Range | Accuracy 1 | Minimum headroom | Minimum test radius | Minimum substrate thickness |
![]() | CO600F1S | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 80mm | 5mm | 0.8mm |
| CO600F2S | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 80mm | 5mm | 0.8mm | |
| CO600F5S | 9 | 40 | 50 | 0.5mm | ± 1-3% or 2.0μm | 80mm | 5mm | 0.8mm | |
| CO600F1H | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 80mm | 5mm | 0.8mm | |
| CO600F2H | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 80mm | 5mm | 0.8mm | |
| CO600N1S | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 80mm | 5mm | 0.3mm | |
| CO600N2S | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 80mm | 5mm | 0.3mm | |
| CO600N5S | 9 | 40 | 50 | 0.5mm | ± 1-3% or 2.0μm | 80mm | 5mm | 0.3mm | |
![]() | CO600F1R | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 30mm | 5mm | 0.8mm |
| CO600F2R | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 30mm | 5mm | 0.8mm | |
| CO600N1R | 9 | 40 | 50 | 1.5mm | ± 1-3% or 2.5μm | 30mm | 5mm | 0.3mm | |
| CO600N2R | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 30mm | 5mm | 0.3mm | |
![]() | CO600F3S | 16.5 | 40 | 50 | 13.0mm | ± 1-3% or 50μm | 80mm | 10mm | 1.0mm |
| CO600F4S | 24 | 60 | 50 | 26.0mm | ± 1-3% or 100μm | 120mm | 30mm | 1.0mm |
*High temperature probe temperature is 250°C
HTechMT CO600N2R Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Eddy Current |
| Measurement range | 5000μm |
| margin of error | ±1~3%/±20μm |
| thinnest substrate | 0.8mm |
| Test environment | Nonmagnetic metal substrate |
| probe | Right Angle Probe |
| Minimum headroom | 30mm |
| Minimum measurement surface | R5mm |
| Probe contact surface diameter | 9mm |
HTechMT CO600N2R Coating Thickness Gauge Packing list
host X1, AA battery X2, test piece set X1, zero adjustment plate X1, certificate X1, manual X1, silicone protective cover X1, instrument bag (cloth bag) X1.
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


CO600N2R