      Home> Miscellaneous instruments> AISRY> AISRY ASR-4327 Leakage and marking Tester

      CHINA ASR-4327 Leakage and marking Tester

      The electrode cross-sectional area is 2mm × 5mm two rectangular platinum electrodes, one end edge is a 30 ° slope, the test Voltage is 100~600V, and the dripping time interval can be set arbitrarily, in line with the GB/T4207 test standard.

      Brand
      SKU: NB031346
      China AISRY
      VS
      Genuinegoods
      • AISRY ASR-4327 Leakage and marking TesterOverview

      • Specifications
      • Comments
      • FAQs
      ASR-4327
      Leakage and marking Tester
      • CHINA ASR-4327 Leakage and marking Tester
      • CHINA ASR-4327 Leakage and marking Tester Figure 1
      • CHINA ASR-4327 Leakage and marking Tester Figure 2
      The electrode cross-sectional area is 2mm × 5mm two rectangular platinum electrodes, one end edge is a 30 ° slope, the test Voltage is 100~600V, and the dripping time interval can be set arbitrarily, in line with the GB/T4207 test standard.

      Introduction

      The tracking Tester adopts rectangular platinum electrodes, and the forces exerted by the two electrodes on the sample are 1.0N±0.05N respectively. The applied Voltage is adjustable between 100-600V (48-60Hz). When the short-circuit current is 1.0±0.1A, the Voltage drop should not exceed 10%. When the short-circuit leakage current is equal to or greater than 0.5A in the test circuit, the time is maintained After 2 seconds, the relay acts to cut off the current, indicating that the test piece is unqualified. The time constant of the dripping device is adjustable, precisely controlling the dripping volume of 44-50 drops/cm3 and the dripping time interval of 30±5 seconds.

      The tracking Tester complies with GB/T4207 test standard. 


      VS

      AISRY ASR-4327 Leakage and marking TesterSpecifications

      LIST VALUE
      Electrode Two rectangular platinum electrodes with a cross-sectional area of 2mm × 5mm, and one end edge is a 30 ° slope.
      surface force 1.0±0.05N
      test Voltage 100~600V
      Maximum test current 3A
      Two electrode distance 4.0mm
      Dripping device The dripping time interval can be set arbitrarily
      Test chamber Volume 0.5M3, D x W x H 60x95x90cm
      Dimensions Depth * width * height 61 * 120 * 105cm
      Box material Electrostatic paint and mirror stainless steel.

      AISRY ASR-4327 Leakage and marking Tester Packing list

      Host X1, manual X1, warranty card X1, certificate X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Leakage trace electrolysis how to adjust?
      [A]
      The electrolysis solution is used to simulate conductive deposition impurities on the surface of solid insulating materials. From the purpose and method of the leakage marking test, the setting of the electrolysis solution is a key factor for the leakage marking test. The electrolysis solution of the leakage marking test is (ammonium chloride) NH4CI, and the solution configuration is to add (0.100 +/- 0.002) grams of NH4CI solid to 100ml of distillation water or deionized water, and the purity is not less than 99.8%.
      +AISRY ASR-4327 Leakage and marking Tester Big data
        +AISRY ASR-4327 Leakage and marking TesterSimilar products
        +Navigation
        AISRY
        CHINA ASR-4327 Leakage and marking Tester
        Service
        Focus on online sales of Lab Testing Instruments