AIC ADJ-2001-M Laboratory Ultrapure Water System
The AIC laboratory ultra-pure water machine ADJ-2001-M uses tap water to produce pure water of grade III and I, and the RO water production is 480L/day. ADJ-2001-M uses dual-wavelength UV UV Lamp sterilization, with UV and other failure alarm functions. RO film and other accessories are imported products.
-
BIO0021 Puro50 Laboratory Water Purification System, three-stage water 50L/H water storage tank 100L
$ 8621.00 -
BIO0021 Puro50 Laboratory Water Purification System, three-stage water 50L/H water storage tank 30L
$ 7999.00 -
TIANMA UPTM-B100 Vertical ultrapure water mechanism Water volume 100L/H
$ 2984.00 -
TIANMA UPTM-C40 Vertical ultrapure water mechanism Water volume 40L/H
$ 4246.00 -
LEICI UPW-P Ultrapure Water System
$ 2218.00
Features
The product's small integrated design, modularization, and quick-connect internal design make it easy to install and maintain, occupy a small area, and have a beautiful appearance;
Dual-wavelength UV ultraviolet lamp (185/254nm) effectively sterilizes the ultra-purification system and oxidizes and decomposes organic matter. Effectively remove nuclease, deoxyribonuclease, bisphenol A, diethyl phthalate and other heat sources and particulate matter;
Optional timed water fetching program design can be selected to avoid waiting for manual water fetching;
Quickly reaches 18.25MΩ.cm@25℃ after power-on, stable water quality, saving water, electricity and time;
The microcomputer chip fully automatically controls the operation of the equipment and meets GLP safety requirements;
Humanized design, intuitive display of operating status, and easy operation;
Power-on self-check, water shortage protection alarm, automatic reset after power outage, automatic shutdown when pure Water Tank is full, ultra-low Voltage protection, RO automatic flushing, UV lamp failure alarm and other functions;
Using imported RO membrane, ion exchange resin, polished nuclear grade resin, silent high-pressure pump, solenoid valve, etc., product performance is maximized;
RO automatically flushes and sterilizes regularly to maximize the service life of accessories;
Water quality online monitoring system can instantly measure the quality of produced water;
Optional RS232 interface to record historical water quality conditions; various specifications of dedicated Water Tanks for pure water are available as standard.
Features
Important parts are imported with original packaging, and the materials comply with the standards of the American NSF and Water Quality Association;
Strictly implement the ISO9001:2008 quality management system to ensure uniform and stable product quality;
Standardized module design and production make product maintenance more secure;
The "preventive maintenance" after-sales service system, combined with the Ecopu EMOAS network management platform, computerizes the historical operating status of the equipment to ensure long-term stable operation of the equipment.
Standards compliant
Comply with ISO3696:1987
Comply with GB/T6682-2008
Compliant with CLSI
Complies with American Society for Testing and Materials (ASTM) D1193-06 Standard specification for Reagent Grade Water
Comply with purified water standards of EP, USP and Chinese Pharmacopoeia
Scope of application
Gas chromatography analysis, chromatography mass spectrometry, atomic absorption spectroscopy, atomic emission spectroscopy, spectrophotometry, ultra-high pressure liquid chromatography, effective liquid chromatography, protein electrophoresis, NP analyzer, VOC analysis, TOC analysis.
Introduction to component functions
1) PP fiber filter
Its function is to filter out impurities such as fine particles, suspended solids, and colloids in the source water to prevent the reverse osmosis membrane from being polluted. The filter is equipped with a PP filter element, which needs to be cleaned and replaced regularly to ensure the quality and quantity of filtered water.
2) AC activated carbon filter
The activated carbon column filter uses columnar activated carbon columns to absorb organic matter and free chlorine in the water, purify the water quality, and ensure that the ion exchange resin is not damaged by oxidants. It needs to be cleaned and replaced regularly to ensure the quality and quantity of filtered water.
3) Booster pump
Provide the required inlet water pressure and flow rate for the reverse osmosis system.
4) RO membrane module
Reverse osmosis treatment can precisely filter out bacteria, viruses, metals, salts, pesticides and various carcinogens in the water, and reduce the ion content in the water. It can save a lot of energy and reduce the operating cost of the system.
ââMembrane desalination rate>99% Bacteria removal rate>99.5%
ââHas good removal effect on organic matter, with molecular weight cut-off below 300
ââNo chemicals or acid-base regeneration treatment, no pollution
ââThe system has simple design, easy operation, stable product water quality, and small floor space.
ââThe workload of operation, maintenance and equipment repair is very small, and the operating cost is low
5) Water tank
Store reverse osmosis produced water to alleviate the contradiction in demand for pure water during peak periods.
6) Purification column
The purification column is equipped with anion and cation exchange resin. Its exchange principle is the same as the above-mentioned ion exchange processing unit. The difference is that this device does not require on-site regeneration. It is a replacement type, has a small footprint, is environmentally friendly, has stable water quality, and is simpler and more convenient to operate.
7) UV sterilization device
Use ultraviolet light with a wavelength of 254nm to remove bacteria in the water and protect the rear-stage reverse osmosis membrane from bacterial contamination.
AIC ADJ-2001-M Ultrapure water machineSpecifications
| LIST | VALUE |
|---|---|
| Flow Rate | Class I ultrapure water ≥ 2L/min |
| Ultrapurification Unit Capacity | 480L/day |
| Produced water quality | tertiary water |
| Ultrapure water quality | Class I ultrapure water |
| Inlet source | tap water |
| Operating Environment | Temperature 5-40 ℃, avoid direct sunlight |
| Power | 220V/50HZ, Power: 150W |
| Interface | Optional RS232 interface |
| Inlet source | TDS: < 200ppm; pH: 6.5-8; Free Chlorine: < 1ppm; Pressure MIN Minimum: 0.2MPa; Pressure MAX Maximum: 0.5MPa; Temperature: 5-35 ℃ |
| Pure Flow Rate index | Conductivity: < 10μs/cm@25 ℃, meeting the Chinese laboratory water standard GB/T6682-2008 three-level water standard |
| Ultrapure Flow Rate index | Electrical resistivity: 18.25MΩ .cm@25 ℃; particles (> 0.2μm): < 1/ml; microorganisms < 1/ml; TOC < 10ppb |
AIC ADJ-2001-M Ultrapure water machine Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- How to troubleshoot common faults in laboratory ultra-pure water machines?
- How to solve the blockage of reverse osmosis membrane in ultra-pure water machine?
- What should I do if the solenoid valve of the experimental ultra-pure water machine encounters these failures?
- How long is the normal replacement cycle for the consumables of the experimental ultrapure water meter?
- How to choose a suitable laboratory ultra-pure water machine?
- What is the difference between "water intake flow" and "water intake flow rate" in laboratory ultrapure water machines?
- Daily maintenance of laboratory ultra-pure water machine
- What kind of water substances can the ultrafiltration system of the ultrapure water machine filter?
- Molar reverse osmosis membrane performance parameters and cleaning and maintenance
- Principle and Maintenance of RO_SPC Series Biochemical Ultrapure Water Machine


AIC