Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Chromatograph> Macy> Macy GC5890N Gas Chromatograph
      Macy GC5890N Gas Chromatograph

      MACY GC5890N Gas Chromatograph

      MACY instrument Gas Chromatograph GC5890N furnace size 28 × 30 × 18cm, is a laboratory Gas Chromatograph, Temperature range + 5~ 420 ℃, GC5890N is the use of digital electronic circuits, can be installed different Detector to meet different chromatograph detection.

      Brand
      SKU: NB031431
      China Macy
      Model
      VS
      MacyLOGO

      Macy

      Information
      Genuinegoods
      • Macy GC5890N Gas ChromatographOverview

      • Specifications
      • Comments
      • FAQs
      GC5890N
      Gas Chromatograph

      Instrument Introduction

      GC 5890N gas chromatograph is a new generation of laboratory gas chromatograph that uses international professional technology, integrates the advantages of domestic (CN) instruments, carries out technological innovation on products, and comprehensively upgrades and launches. A variety of Detectors and packed columns, split/splitless capillary column injection systems are optional; Fully compatible with the Agilent 6890N GC Detector and associated Detector control boards, chromatography workstations, and autosamplers. The cost performance is very good, the performance is excellent, and the operation is stable and reliable.

      Performance characteristics:

      1. High-precision, multi-functional, connected to international professional technology

      • The new integrated digital electronic circuit has high control accuracy, stable and reliable performance, and can reach a temperature control accuracy of 0.01°C.

      • It has the function of self-diagnosis at start-up, the function of stopwatch (convenient for flow measurement), the function of running timer, the function of power failure storage protection, the function of keypad locking, the function of anti-power mutation interference, the function of networked data communication and remote control. 

      2. The unique design of the sampling system can obtain a lower detection limit

      • Unique inlet design solves injection discrimination; The double-column compensation function not only solves the program drift caused by the temperature rise, but also subtracts the effect of background noise to obtain a lower minimum detection limit.

      • There are packed columns, capillary split/splitless injection systems (with diaphragm cleaning).

      • Automatic/manual gas six-way injector injector, headspace injector, thermal analysis injector, pyrolysis furnace injector, methane reformer, autosampler are optional. 

      3. The program temperature is raised, the furnace temperature is precisely controlled, and the stable balance is faster

      • The column box has a large volume, and the intelligent rear door opening system has stepless variable air inlet and outlet volume, which shortens the stable equilibrium time of each Detector system after program lifting/cooling; Heating furnace system: ambient temperature +5°C~420°C; 7-stage programmed heating, heating rate 0.1~120°C/min; The furnace temperature can be recalibrated by the user, and the maximum temperature can be set within 420°C, and the temperature equilibration time of the furnace can be determined by the user. 

      4. High sensitivity and high stability Detector to meet the needs of different schemes

      • Six Detectors can be installed: Hydrogen Flame Ionization Detector (FID), Thermal Conductivity Cell Detector (TCD), Electron Capture Detector (ECD), Flame Photometric Detector (FPD), Nitrogen and Phosphorus Detector (NPD), and Photoionization Detector (PDHID).

      • Each Detector can be independently controlled, and the hydrogen flame Detector is easy to remove and install, making it easy to clean or replace the nozzle.

      • Thermal Conductivity Cell Detector (TCD) Stability Time: ≦10min.

      Scope of application

      Forensic science: testing of volatile poisons such as alcohols, aldehydes, and ketones in blood and urine.

      Traffic safety: the test of the blood alcohol content of the vehicle driver when drinking alcohol and driving while intoxicated.

      Brewing industry: Determination of low boiling point aroma components in beer.

      Food industry: Detection of solvent residues in leaching oils.

      Environmental protection: such as the determination of volatile halogenated hydrocarbons in surface water and tap water such as rivers, rivers and lakes.

      Industry: Detection of residual solvents in *products.

      Material control: Detection of acetaldehyde residues in beverage bottles.

      VS

      Macy GC5890N Gas ChromatographSpecifications

      LIST VALUE
      Column thermostat - furnace size 28×30×18cm
      Column thermostat - Temperature range Room temperature + 5~ 420 ℃
      Column thermostat - temperature setting 1℃
      Column thermostat - programmed Heating rate 0.1℃
      Column thermostat - maximum Heating rate 120℃/ min
      Column Thermostat - Temperature Fluctuation Environmental temperature change of 1 ℃ is 0.01 ℃
      Column thermostat - programmed temperature 7-Step program to heat up, can run Column bleeding compensation (dual channel)
      Injection port A variety of injection ports can be equipped with: Packed column injection port, shunt/non-shunt capillary tubing injection port, programmed temperature cold column injection port
      Flame ionization Detector, FFID - Maximum operating temperature :400℃
      Flame ionization Detector, FFID - detection limit ≤5×10(-12)g/s [n-C16]
      Flame ionization Detector, FFID - drift ≤5×10(-13)A/30min
      Flame ionization Detector, FFID - Noise ≤2×10(-13)A
      Flame ionization Detector, FFID - Dynamic linear range ≥10000000

      Macy GC5890N Gas Chromatograph Packing list

      Host x1, Hydrogen Flame Detector (FID) x1, capillary tubing shunt/unshunt Sample injector system x1, consumables and start-up kit x1, special chromatograph work HW-2000x1, special Chromatography Column x1, air generator MXA-2Lx1, hydrogen generator MXH-300x1, high purity nitrogen cylinder x1, automatic headspace Sample injector X710Ax1, special computer printer x1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Do you have the Gas Chromatograph required in the GB/T12033 standard?
      [A]
      This GC5890N Gas Chromatograph will do.
      Macy
      MACY GC5890N Gas Chromatograph
      Service
      Focus on online sales of Lab Testing Instruments