NIRUN CPE-41 cone-plate viscometer rotor, shear rate 2.0N
Shear rate 2.0N, sample size 2.0ml, suitable for Viscometer host NTV-CAP1.
NiRun-
HUINUO RVDV-2 digital display Rotational Viscometer 4 million CP with a small number of sample adapters
$ 2011.00 -
NIRUN LPDV-1 Portable Digital Viscometer Measurement range 25~ 150,000 mPa · s
$ 1224.00 -
HUINUO NDJ-1S digital display Rotational Viscometer 100,000 CP with printer
$ 480.00 -
HUINUO LVDV-1 digital display Rotational Viscometer 6 million mPa · s 99.9rpm
$ 1061.00 -
TQC DV2011 Viscometer 0-75P For DV2700 Rotothinner Rotational Viscometer
$ 647.00
Introduction
NIRUN CPE-41 cone-plate viscometer rotor is an optional rotor for NTV-CAP1 series cone-plate viscometer. The shear rate of CPE-41 is 3.84N and the applicable sample volume is 0.5ml.
Comparison of NTV-CAP1 series parameters
| NTV-CAP1 Viscosity range (mPa.s) Measurement accuracy: ±1% (FS) Plate temperature range: -1°C--150°C Accuracy: ±0.1°C | |||||
| Model/Rotor No. | CPE-40 | CPE-41 | CPE-42 | CPE-51 | CPE-52 |
| shear rate | 7.5N | 2.0N | 3.84N | 3.84N | 2.0N |
| sample size | 0.5ml | 2.0ml | 1.0ml | 0.5ml | 0.5ml |
| NTV-CAP1LV | 0.1-3,000 | 0.5-11,000 | 0.2-6,000 | 2-48,000 | 3-92,000 |
| (RPM: 0.1-250) | |||||
| NTV-CAP1RV | 1-32,000 | 5-122,000 | 2-64,000 | 20-512,000 | 39-983,000 |
| (RPM: 0.1-250) | |||||
| NTV-CAP1HA | 2.6-65,000 | 10-245,000 | 5-128,000 | 41-1M | 78-2M |
| (RPM: 0.1-250) | |||||
| NTV-CAP1HB | 10.5-261,000 | 39-982,000 | 20-512,000 | 163-4M | 314-7.8M |
| (RPM: 0.1-250) | |||||
Note: N means speed rpm
NiRun CPE-41 rotorSpecifications
| LIST | VALUE |
|---|---|
| shear rate | 2.0N |
| sample size | 2.0ml |
| Adapted Viscometer Host | NTV-CAP1 |
NiRun CPE-41 rotor Packing list
Rotor X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- The relationship between intaglio ink viscosity and viscoelasticity
- Thixotropic Cracking Coefficient Method for Determination of Ink Rheology
- The working principle and application of viscosity meter
- What are non-Newtonian fluids?
- How to Choose a Conical Rotor for Viscosity Measurement
- What is a Newtonian fluid?
- The working principle of belt viscometer
- Comparison of 3 viscosity measurement methods: capillary method, rotation method, falling ball method
- How to choose the right viscometer rotor?
- The relationship between paste ink and viscosity (viscosity)


CPE-41






