LEICI WZT-701 Online turbidity monitor
LEICI WZT-701 online turbidity monitor can display turbidity and temperature values at the same time, the measurement range is 0.00~500.0NTU, WZT-701 online turbidity monitor is used to measure the turbidity value of tap water, drinking water, surface water, industrial process water.
LeiCi-
Qiwei WGZ-1000AS Microcomputer Turbidity Meter 0~1000NTU
$ 324.00 -
JINGQI SS-200 Portable Suspended Solids Tester
$ 560.00 -
Yuefeng SGZ-400B Portable Turbidity Meter 0~400NTU/0.01
$ 381.00 -
Qiwei WGZ-400BS Microcomputer Turbidity Meter 0.01NTU
$ 271.00 -
JINGQI WGZ-400P Precision Turbidity Meter 400NTU +/- 2% tape printing
$ 745.00
Product Description
Using large-screen dot matrix LCD, it can display turbidity and temperature values ââat the same time;
Supports single-point calibration or two-point calibration;
Supports automatic upper and lower limit alarm functions and power-off protection functions;
With (4~20) mA DC isolation signal output, the output upper limit and output lower limit can be set arbitrarily;
With RS-232 digital interface.
LeiCi WZT-701 Online turbidity monitorSpecifications
| LIST | VALUE |
|---|---|
| Measurement parameter | turbidity |
| Measurement principle | Photometric 90 ° scattering method |
| Sensors | TSC-10S turbidity Sensors (Imported) |
| Measurement range | (0.00~500.0)NTU |
| resolution | 0.01NTU,0.1NTU |
| Instrument intrinsic error | ±10% |
| Repeatability | ≤2% |
| Zero drift | +/- 0.5% FS (within 30min) +/- 1% FS (within 24h) |
| Range drift | +/- 5% FS (within 24h) |
| Installation method | Instrument: Wall Mount Sensors: Circulation |
| Output signal | (4~ 20) mA DC, maximum load 750Ω |
| Output signal | RS-232 |
| Alarm, control relay touchpoint Capacity | 2.5A, 250V AC (non-inductive) |
| Flow rate of water sample | (100~120)mL/min |
| Water sample pressure | (7~140)kPa |
| Sensors Cable length | 9m |
| water inlet and outlet interface | 3/8 "quick plug |
| Protection level | IP65 |
| Operating Environment | Environmental temperature: (5~ 40) ℃, Relative Humidity: not more than 90% |
| Power Supply | AC(220±22)V,(50±1)Hz |
| opening size | 140×140 |
| Size (mm), Weight (kg) | 166×166×110,2 |
LeiCi WZT-701 Online turbidity monitor Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJIS K0801-1986
- ActiveJJF 1700-2018
- ActiveJJF 1571-2016
- Active 100-2007
- ActiveDIN EN ISO 15715-2006
- ActiveGB/T 13531.3-1995
- ActiveGB/T 13200-1991


WZT-701