ELCOMETER F510-50T Automatic Adhesion Tester Superior
The Elcometer 510 automatic pull-out Adhesion Tester accurately measures the adhesion force between coatings and substrates. The F510-50T is an advanced Adhesion Tester with a kit size of 50mm and a range of 0.3 to 4MPa/50 to 580psi.
ElcometerIntroduction
The Elcometer 510 Automatic Pull-Off Adhesion Tester accurately measures the adhesion between the coating and the substrate.
Features
Handheld design, waterproof and durable, equivalent to IP64 design
A fully automatic hydraulic oil pump ensures smooth and continuous pressure application to provide consistent, repeatable results
Fully adjustable tensile rate 0.1-1.4MPa/sec (15-203psi) to meet national and international levels
User-definable measurement range and scale with an accuracy of ±1%:
10mm Forging Die : 100MPa/14400psi
14.2mm Forging Die : 50MPa/7200psi
20mm Forging Die : 25MPa / 3600psi
50mm Forging Die : 4MPa / 580psi
User-definable limits with unique pressure hold and release features
The Advanced (T-type) stores up to 60,000 readings with individual pulls, up to 2,500 alphanumeric batches, and complete fault information with attributes
Intuitive and easy-to-use menu structure, multi-Chinese
10, 14.2, 20 and 50mm diameter dolly options
Meets standards
ASTM C1583, ASTM D4541,ASTM D7234-12, AS/NZS 1580.408.5,BS 1881-207, DIN 1048-2,EN 1015-12, EN 12636, EN 13144,EN 1542, EN 24624, ISO 16276-1,ISO 4624, JIS K 5600 5-7, NF T30-606,NF T30-062
Characteristics:
Powerful
Suitable for metal, wood, concrete and other substrates
Smoothly applied loads up to 100MPa (14400psi)
USB and Bluetooth® data output to iOS or Android devices
The advanced (T-type) can store 60,000 data in 2,500 groups
effective
Ideal for both laboratory and field use
10, 14.2, 20 and 50mm (0.39, 0.56, 0.761.96") diameter reusable dollies
Compatible with ElcoMaster® and ElcoMaster® mobile apps
Measure on small, curved or flat surfaces
durable
Sealed, heavy-duty, impact-resistant
Dustproof and waterproof rating, equivalent to IP64
Suitable for extreme environments
Accurate readings
Measuring range up to 100MPa (14400 psi) with accuracy of ±1% of all scale ranges
It can be used in accordance with a number of national and international standards
Features
![]() | ![]() | ![]() |
Automatic adhesion Tester with optional pullingRate 10, 14.2, 20&50mm diameter forgingModel. | View the trend chart or the reading value statistics next to itData. | Individual user-definable pull-out charts can be guaranteedSave each reading. |
![]() | ![]() | ![]() |
| Store individual readings and pull-rate plots in up to 2500 alphanumeric batches, along with date, time and attribute information. | Either pull to maximum or pull to preset limit. The unique Time Hold feature allows the user to set a delay before the pressure returns to zero. | Adhesion pull data in accordance with national and international standards are saved together with the adhesion shedding/cohesion shedding properties. |
Other features:
![]() | ![]() | ![]() |
By standard rechargeable battery or AC power supplypower, each rechargeable battery performs up to 200Pull. Battery charging time < 300 minutes | Transfer data via USB or Bluetooth®Your computer is carried out with the ElcoMaster® softwareFurther analysis or check in ElcoMaster®Look at the pull-out rate chart for the field test. | Use a wireless Bluetooth ® communication link Testerto an Android or iPhone phonedevice, GPS coordinates from your mobile deviceCan be added to the report and emailedSend it instantly. |
![]() | ![]() | ![]() |
A range of standard and thin substrate brake skirtsAllows instruments with 10, 14.2, 20 or reweightableUse a 50mm diameter forging die, nonOften suitable for thick, thin, flat or convex substratesTest coatings. | Optional magnetic anchor clamps ensure that the actuator is in the testVertical surfaces or test heights do not fall. | Supplied in a sturdy plastic suitcase, Easy to carry to the job site |
ElcoMaster software
ElcoMaster is fast and easy to use softsolutions for all your data management and Quality assurance is needed at the point of a buttonPrepare a professional inspection report.
Whether you are on-site or at the factory, with the ElcoMaster® mobile app users can:
Store field readings directly to your mobile device and save them to batches.
View the pull-out rate graph in real-time while the test is being conducted.
Add attribute data to each data set of readings.
At the click of a button, photos of the dolly and test surfaces can be added to each individual data set for readingNumber.
Plot a single reading into a map of locations, photos or charts.
Inspection data can be transferred from a mobile phone to a computer for further analysis and reporting.
Generate .pdf file submissions instantly.
Data transferred from the instrument to the ElcoMaster includes:
Adhesion measurement
Date and time
Adhesion shedding/cohesion shedding properties
Dolly size
Pull-out rate chart
Pull to Limit/Highest
Limit values
Hold the time limit
Cutting device
Number of layers
Skirt cover type/support ring size
Data Group Information > Statistics
Calibration information
Calibration verification date/time
Product comparisons
| Features | Standard Type(S) | Advanced(T) |
| Measurement data can be reproduced repeatably | √ | √ |
| The menu structure is convenient and easy to understand; Multi-Chinese languages | √ | √ |
| Strong, resistant, waterproof and dustproof; Equivalent to IP64 | √ | √ |
| Bright LCD color screen; with ambient light sensor | √ | √ |
| Scratch and solvent resistant display; 2.4" (6cm) TFT | √ | √ |
| Calibration certificate | √ | √ |
| Rotate the screen automatically; 0°, 180° | √ | √ |
| Data output via USB (field readings - and batches) | √ | √ |
| Data ® is output via Bluetooth | √ | |
| Computer commands; start and stop the instrument from a computer with real-time readings (USB only) | √ | |
| Switching Units (MPa, psi, N, N/mm-2) | √ | √ |
| On-screen statistics (η, x, σ, hi, lo, COV, N>hi limit♦) | √ | √ |
| Pull-out rate metric | √ | √ |
| Trend charts | √ | √ |
| Pull-out Diagram (Load v-Time) | √ | |
| Choice of interchangeable dollies; 10,14.2,20 & 50mm | √ | √ |
| The user can select the extraction rate; (Model S & Model T standard mode) 10mm: 1.00, 2.00, 3.00, 4.00, 5.00 MPa/s 125, 200, 400, 600, 725psi/s 14.2mm: 0.4, 0.7, 1.4, 2.0, 2.5 MPa/s 60, 100, 200, 300, 360psi/s 20mm: 0.2, 0.3, 0.7,1.0, 1.2 MPa/s 30, 50, 100, 150, 180psi/s 50mm: 0.04, 0.08, 0.12, 0.16, 0.20 MPa/s 5, 8, 16, 24, 30psi/s | √ | √ |
| The user can select the extraction rate; (Model T Advanced Mode) 10mm: 0.4 - 5.60 MPa/s 58 - 812 psi/s in 0.1 MPa/1 psi step 14.2mm: 0.2 - 2.80 MPa/s 29 - 403 psi/s in 0.1 MPa/1 psi steps 20mm: 0.1 - 1.40 MPa/s 15 - 203 psi/s in 0.1 MPa/1 psi steps 50mm: 0.02 - 0.22 MPa/s 2 - 32 psi/s in 0.1 MPa/0.1 psi steps | √ | |
| User-selectable limits and hold time limits | √ | |
| instrument memory; The most readings | 60 | 60,000 |
| Number of data sets | 1 | 2500 |
| Attribute models to comply with national and international standards | √ | √ |
| Display mode | √ | √ |
| Readings, Selected Statistics & Trend Charts (Last 20 Readings) | √ | √ |
| Pull-out rate chart | √ | |
| Review the data set | √ | |
| Power Supply, Battery (B), AC Main Power Supply (M) | B | B, M |
| USB cable with ElcoMaster™2.0 CD | √ | √ |
| Power cord with multi* adapter plug (UK, EU, US, AU) | √ | |
| Plastic suitcase | √ | |
| Date and time | √ | |
| Adhesion calibration verification mode in the field | √ |
Elcometer F510-50T Automatic Adhesion TesterSpecifications
| LIST | VALUE |
|---|---|
| Pressure Accuracy | Full scale +/- 1% |
| Resolution | 0.01MPa(1psi) |
| Draw Rate Accuracy | +/- (2.5% + 0.3 seconds) |
| Resolution | 0.01MPa(1psi/s) |
| Kit diameter | 50mm |
| Range | 0.3~4MPa/50~580psi |
| pull rate range | 0.02 - 0.22MPa/s(2 - 32psi/s) |
| Dimensions | 260*100*66mm |
| Brake height | 85mm |
| Weight | 2.9Kg |
| Kit Weight | 6.1kg (13.5lb) |
| Power | 8 x AA NiMH/alkaline batteries (16 rechargeable batteries with charger) or AC mains (Model T only) |
| Battery life | 200 pulls per charge, up to 25MPa (3600psi) at 1MPa/sec (150psi/sec), Charging time < 5 hours p = "> |
Elcometer F510-50T Automatic Adhesion Tester Packing list
Host X1, 50mm forging die X6, 50mm forging die standard skirt cover X1, 50mm forging die cutting shaft X1, 50mm forging die cutter X1, Araldite standard two-component epoxy glue X2, grinding pad X1, shoulder strap X1, suitcase X1, AA rechargeable battery & charger X1, main power supply X1, USB cable X1, CD X1, calibrate certificate X1, operation instructions X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ELCOMETER 123 Surface Roughness Tester Operation Method
- Elcometer 456 A456CFNFBI1 Coating Thickness Gauge Beauty Appreciation
- Comparison of two concrete Coating Thickness Gauges
- Eletroplating Nickel Thickness Gauge Selection Case on Steel
- British elcometer Coating Thickness Gauge classification
- What is the accuracy of Elcometer Coating Thickness Gauge?
- One article takes you to know glossiness, reflectance and fog shadow
- Elcometer 506 Adhesion Tester Features
- Elcometer 456 Coating Thickness Gauge
- Elcometer 355 Coating Thickness Gauge Iron and non-iron based probe selection table
- ActiveSH/T 3022-2019
- ActiveASTM D7234-2012
- ActiveGB/T 39289-2020
- ActiveHG/T 20720-2020
- ActiveHG/T 4340-2012
- ActiveHG/T 2454-2014
- ActiveASTM B571-2023
- ActiveISO 4624-2016
- AbolishISO 4624-2002
- AbolishGB/T 5210-1985
- ActiveGB/T 5210-2006


F510-50T