TQC SP1680 film adjustable cross-cut adhesion instrument set CC3000 series
1Mm cutter tooth spacing, 6 teeth; with auxiliary wheels to maintain a fixed distance; suitable for sturdy substrates; vacuum hardened stainless steel cutter head.
-
RDS 6 #3/8 "Mayer Rods WFT 13.7μm Length 400mm
$ 161.00 -
TQC SP3020 adhesion tape 3M adhesion 7.6 N/cm
$ 162.00 -
YUEPING FA2104J Electronic Analytical Balance Weighing Range: 0~210g Repeatability Error : +/- 0.0002g
$ 658.00 -
TQC SP3010 adhesion tape tack good not degumming mass performance stable
$ 155.00
Introduction to the test of 100-grid knife drawing method
The 100-grid knife is an instrument manufactured by using the principle of the adhesion test of the grid method and used to determine the adhesion of the paint film, which is used to evenly draw out a square of a certain size and size, and evaluates the adhesion degree of the coating film to the substrate by evaluating the integrity of the coating film in the grid, which is represented by 'grade'. It is mainly used for the determination of adhesion of organic coatings by the grid method, not only for the laboratory, but also for the construction site under various conditions.
The "grid method" is widely accepted in CHINA and has been rated as a fast and effective method for determining adhesion by international standards. There are various styles and adhesion test methods of 100-grid knives, and they have been used to evaluate the adhesion of paint coatings.
In the process of adhesion test, there are many influencing factors, such as the flexibility of the coating, the presence of an interfering layer (whether there is an interfering layer between the coating and the substrate), etc. The scribing method is mainly cut with a 100-grid knife with single or multi-piece cutting, and after the development, there are many more functional, more convenient and effective models, which can directly show the adhesion of the tested product.

Introduction
TQC CC3000 series adjustable grid adhesIon Meter imported from the Netherlands, with SP1680,SP1681、SP1682、SP1683、SP1684 five models,The accuracy can be adjusted according to the specific test needs to achieve a precise cutting depth for more accurate testing of adhesion. Compared with other brands and other types of 100 grid knives, this set of 100 grid knives has tool sizes that can be used for different coating film thicknesses and substrates according to the standard, and can be applied to a variety of adhesion tests by only adjusting them, which is very convenient. Each set of 100 grid knives consists of a lightweight, comfortable handle, tough knives, and easy to carry. Also included are brushes, small magnifying glasses, and adhesive tape.

Product detail drawing




Baige knife related supporting products
【Sold separately】
SP9700 Illuminated Magnifier 2.5x
SP1710 nylon brush is used for adhesion testing
SP3020 tape, one roll, with an adhesion of 7.6 N/cm
SP3007 tape, one roll, has an adhesion of 4.3 N/cm
SP3010 adhesive tape, three rolls, with an adhesion of 4.3 N/cm
Comparison chart of the whole series of models of TQC adhesion Tester
| TQC | Knife teeth | CC1000 | CC2000 | CC3000 | Suitable for film thickness environments |
| Scratch lattice adhesion instrument | - | The blade holder is automatically adjusted, and the round cutter has 8 cuts | The blade holder is automatically adjusted, the cutter can be easily changed, and the swivel handle is included, eliminating the need for additional tools | The blade holder maintains a fixed distance between the varnish surface and the two auxiliary wheels, and the cutting depth can be precisely adjusted to ensure repeatability | - |
| ISO2409/ASTM D3359 | 1 | VF1839 | SP1690 | SP1680 | ISO2409: 0~60μm (sturdy substrate); ASTM D3359: 0~50μm (Robust Substrate) |
| ISO2409/ASTM D3359 | 2 | VF1842 | SP1691 | SP1681 | ISO2409: 0~60μm (soft substrate), 61-120μm(Sturdy substrate.)); ASTM D3359:50~125μm (Solid Substrate) |
| ISO/DIN2409 | 3 | VF1844 | SP1692 | SP1682 | 121-250μm(Sturdy substrate.)) |
| ASTM 3359<2009 | 1 | VF1846 | SP1699 | SP1683 | 0~50μm(Sturdy substrate.)) |
| ASTM 3359 is less than 2009 | 1.5 | VF1847 | SP1700 | SP1684 | 50~125μm(Sturdy substrate.)) |
Take you to the Dutch TQC



TQC sheen SP1680 Adjustable cross-cut adhesion TesterSpecifications
| LIST | VALUE |
|---|---|
| Number of teeth | 6 teeth |
| Tooth spacing | 1mm |
| Instrument material | Vacuum hardened stainless steel, aluminum, rubber |
| Application standard | ISO2409、ASTM D3359 |
| Applicable film thickness environment | 0~60μm (solid substrate), 0~50μm (solid substrate) |
| Appearance size | 32*190*42mm |
| Instrument Weight | 352g |
TQC sheen SP1680 Adjustable cross-cut adhesion Tester Packing list
Cross Hatch Cutter x1, 3M Tape x1, Brush x1, magnifying glass x1, Encasement box x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 2163-2024
- ActiveSJ 20910A-2018
- ActiveGB 10810.4-2012
- ActiveGB/T 9286-2021
- AbolishTB/T 2260-1991
- ActiveHG/T 20720-2020
- ActiveHG/T 5776-2020
- ActiveHG/T 5187-2017
- ActiveHG/T 5299-2018
- ActiveHG/T 3829-2006
- ActiveASTM D3359-2023
- ActiveISO 2409-2020
- AbolishISO 2409-2007
- ReplacedGB/T 9286-1998
- ActiveASTM D6677-2022
- AbolishISO 2409-1992
- ActiveHG/T 2003-1991
- ActiveHG/T 2244-1991
- ActiveHG/T 2243-1991
- ActiveQB/T 1551-1992


TQC sheen