YINUO YN-TQD03 Battery Separator Porosity Meter Gurley Bentsen Method
YINUO YN-TQD03 battery separator Porosity meter is the Gurley method, Schopper method, Bentsen method three test methods in one machine, suitable for battery separator, film, paper and other air penetration measurement, YN-TQD03 battery separator Porosity meter test range 0.01-2 um/(Pa.s), transmission rate 0.01-120ml/min (Miscellaneous range optional), resolution 0.001um/(Pa.s).
YiNuo-
YANTE YT-TQD1000 paper Porosity Tester
$ 1092.00 -
PUYUN PY-H614 paper Porosity Tester Schopper type
$ 972.00 -
YINUO YN-TQD01 Schauber Air Permeability Tester
$ 1156.00 -
JINGWEN JW123 paper Air permeability meter
$ 1058.00 -
CHINA BLD-TQ20 paper Porosity Meter
$ 1109.00
use
YN-TQD03 battery separator air permeability Tester is a combination of Gelley method, Shober method, Benteson method three test methods in one machine, suitable for battery separator, film, paper and other air permeability measurement, the instrument includes the following three air permeability measurement methods:
Shober method: Constant differential pressure of 1.00 kPa± 0.01 kPa or 2.50±0.01 kPa, select the appropriate test duration, and determine the air flow through the specimen by test volume.
Geller method: Determination of the time taken to pass through 100 ml of gas at a constant differential pressure of 1.23 kPa.
Benteson method: under a constant differential pressure of 1.47kPa, the air flow through the test surface is recorded after clamping for 5s.
Enforce the standard
SJ_T 10171-2016 General Test Method for Basic Performance of Alkaline Battery Separators (Air Permeability Part)
GB/T 458-2008 Determination of air permeability of paper and cardboard
GB/T 36363-2018 Polyolefin separator for lithium-ion batteries
Scope of application
| Basic application | Films, flakes | All kinds of plastic films, sheets, separators |
| paper | All kinds of paper, cardboard, composite cardboard | |
| Extend your application | Metal sheets, silicon wafers | Silicon wafers, foils, various metal sheets |
| Corrugated cardboard | Corrugated cardboard, containerboard | |
| textile materials | All kinds of textile materials such as woven fabrics, knitted fabrics, coated fabrics, etc | |
| Nonwovens | All kinds of nonwovens such as diapers, towels, medical masks, etc | |
| Other materials | Solid electrical insulating materials, adhesive tapes, geosynthetics, rubber, etc |
peculiarity
(1) The three test methods of Geerley method, Shober method and Bentzor method are integrated into one machine for users to choose freely to meet the testing needs of different users.
(2) The differential pressure of the instrument is adjustable in the range of 0-3KPa, and the accuracy is up to 0.01kPa, which fully meets the requirements of the test differential pressure of the three methods
(3) The ultra-large test volume of the instrument is 1L, which fully meets the volume requirements of the three methods
(4) The free conversion of the test area of 10.0cm2 and 6.42cm2 is realized by adding a mask
(5) The instrument comes with a temperature and humidity sensor to monitor the temperature and humidity of the Test Chamber in real time.
(6) The instrument has good sealing, and the air leakage does not exceed 1.0ml/h
(7) The instrument comes with a display screen and host computer software, which can be operated offline and connected to the computer for synchronous testing
YiNuo YN-TQD03 Battery Diaphragm Porosity MeterSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | 0.01~2.5μm/(Pa.s) |
| transmission rate | 0.01-120Ml/min (Miscellaneous range optional) |
| Resolution | 0.001um/(Pa.s) |
| Differential pressure range | 0-3KPa, Accuracy : +/- 0.01kPa (Miscellaneous range optional) |
| Differential pressure range | Gurley method: 1.23kPa +/- 0.01kPa; Schopper method: 1.00 kPa +/- 0.01kPa or 2.50 +/- 0.01kPa (Gas Flow rate less than 0.13ml/L); Bentsen method: 1.47kPa +/- 0.02kPa |
| test time | 10-6000.0s |
| Sample size | Gurley method: 50mm × 50mm Effective area: 6.42cm2; Schopper method: 60mm × 100mm Effective area: 10.0 +/- 0.2cm2; Bentsen method: 50mm × 50mm Effective area: 10.0 +/- 0.2cm2 |
| Sample temperature and humidity treatment | Pretreatment: < 40 ℃, atmospheric conditions of 10-35% RH, let stand for 24h; the difference between weighing at an interval of 1h before and after is not greater than 0.25% of the total Mass, the sample is equilibrated |
| Dimensions | 500mm*400mm*300mm |
| Power Supply | 220V,50Hz、100w |
| Weight | 25kg |
YiNuo YN-TQD03 Battery Diaphragm Porosity Meter Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Application and Operation of Gurley Method in Measuring Air Permeability of Paper and Cardboard
- How to use the differential pressure method to test air permeability?
- Application of Porosity Tester in Thermal Paper
- Porosity Tester verification & maintenance
- Principles and Methods of Gurley Air Permeability Meter Test Method
- What is the air permeability of paper? How to test?
- How to test air permeability with a non-porous paper air permeability meter?
- What is the measurement principle of microporous paper breathability meter?
- Principles and methods of Bendtsen breathability meter test method
- Principle and method of Schopper air permeability meter test method


YN-TQD03