LEICI ZDCl-2 Potentiometric titrator
Building materials industry-specific, to meet GB/T176/8077 in the chloride ion potential Titrimetric method, cement, concrete, concrete admixtures in the chloride ion content of the test, built-in method in accordance with the requirements of the relevant standards, the results of direct reading.
LeiCi-
HANNA HI931 Automatic Potentiometric titration, poten-tiometry analyzer
$ 8161.00 -
HANNA HI934 Karl Fischer Coulomb Method (KF) Potentiometric titrator
$ 9521.00 -
LEICI ZDJ-5B AutomaticTitrator
$ 6734.00 -
HANNA HI933 Karl Fischer Volumetric (KF) Moisture Meter Potentiometric titrator
$ 9521.00 -
YueFeng ZD-2A Automatic Potentiometric titrator 0~14.00pH
$ 405.00
Instrument use
The ZDCL-2 chloride ion automatic potentiometric titrator is a special instrument specially designed for the building materials industry. The use of the instrument complies with GB/T 176-2017 " Chemical " and GB/T 8077-2012 "Concrete Admixtures". The chloride ion potentiometric titration method in standards such as "Homogeneity Experiment Method" and GB/T50344-2004 "Technical Standard for Inspection of Building Structures" is mainly used in laboratories such as various inspection agencies, cement companies, concrete mixing stations, and scientific research institutes. , has the advantages of easy operation, high accuracy and intelligence.
main feature
â The instrument uses automatic potentiometric titration to test the chloride ion content in cement, concrete, and concrete admixtures. The built-in method is adapted according to relevant standards and the results can be read directly.
â Supports three major types of experiments: cement chloride ion, admixture chloride ion, and concrete chloride ion; built-in silver nitrate calibration, blank experiment, sample measurement and other modes.
â Supports automatic calculation function, which can automatically calculate the concentration of silver nitrate titrant and the concentration of chloride ions in the sample;
â Supports blank titration, which can automatically calculate the blank value and apply it to the determination of the sample (automatically deduct the blank). You can choose to turn off this function;
â Data management function: supports storage of 200 sets of titration results and 1 set of titration curves, measurement information that complies with GLP specifications, and customer traceability information is more complete;
â Support data deletion, review, printing or output;
â Supports both Chinese and English operating languages, and supports power-off protection function;
â Supports USB and RS232 connection to PC, and comes with special software (can view titration data and titration curves, but does not have control functions);
LeiCi ZDCl-2 Potentiometric titrator for chloride ionsSpecifications
| LIST | VALUE |
|---|---|
| Titration analysis, sexual repeability | 0.20% |
| Allowable error of titration Capacity | 10Ml Burette : +/- 0.025ml |
| Burette resolution | 1/10000 |
| Burette infusion or rehydration rate | (55 +/- 10) s (when Burette is full) |
| Potentiometric titration, poten-tiometry - Measurement Range | mV value: (-1800.0~1800.0) mV; temperature: (-5.0~105.0) ℃ |
| Potentiometric titration, poten-tiometry - resolution | mV value: 0.1mV; temperature value: 0.1 ℃ |
| Potentiometric titration, poten-tiometry - intrinsic error | Not more than 0.2 mV |
| Potentiometric titration, poten-tiometry - stability | +/- 0.3mV +/- 1 word/3h |
| Temperature compensation - Measurement Range | (-5.0~105.0)℃ |
| Temperature compensation - resolution | 0.1℃ |
| Temperature compensation - intrinsic error | ±0.3℃ |
LeiCi ZDCl-2 Potentiometric titrator for chloride ions Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveHG/T 6108-2022
- ActiveGB/T 43753.4-2024
- ActiveSN/T 5051-2018
- Active
- ActiveSN/T 5350.1-2021
- ActiveJT/T 1150-2017
- ActiveGB/T 8077-2023
- ActiveGB/T 3884.12-2023
- ActiveGB/T 24890-2010
- ActiveGB/T 3286.3-2012
- ActiveGB/T 6909-2018
- ActiveGB/T 4945-2002
- ActiveGB/T 34694-2017
- ActiveGB/T 9725-2007
- ActiveGB/T 8923.1-2011


ZDCl-2






