CHNSPEC TH-110 Haze meter, light transmitter vertical + horizontal
Adopting dual standard ISO & ASTM, dual-caliber (21mm/7mm) instrument does not need to be preheated, ready-to-use measurement, 1.5 seconds results meet CIE-A, CIE-C, CIE-D65 three standard lighting Light source haze and total transmittance measurement; suitable for plastic, film, Glass, LCD panel, touch screen and other transparent translucent materials haze, transmittance one-stop measurement solution.
CHNSpecFeatures
1. Meet the following test standards: GB/T 2410 standard, ASTM D 1003 standard, ISO 13468 standard, ISO 14782 standard
2. The instrument does not need to be warmed up, it can be measured immediately after use, and the result can be obtained in 2 seconds
3. With 21mm/7mm two measuring caliber
4. Using 7-inch capacitive touch screen, has a good human-computer interaction interface
5. Satisfy the measurement of haze and total transmittance under the three standard lighting sources of CIE-A, CIE-C, and CIE-D65
6. With the haze value self-calibration function, the instrument measurement data is consistent with the target data
7. It has two measurement states of vertical measurement and horizontal measurement, suitable for sample measurement of sheets, films, liquids, etc.
8. With an open measurement area, it can meet the measurement of samples of any size
9. Using LED light source, long life, no need to replace for ten years
10. Small size, light weight, easy to carry
CHNSpec TH-110 haze MeterSpecifications
| LIST | VALUE |
|---|---|
| Light source | CIE-A、CIE-C、CIE-D65 |
| follow the standard | ASTM D1003/D1044,ISO13468/ISO14782,JIS K 7105,JIS K 7361,JIS K 7136,GB/T 2410-08 |
| Measurement parameters | ASTM and ISO Dual Standard Haze (HAZE), Transmittance (T) |
| Light spectrum Response | CIE Light spectrum function Y/V (λ) |
| optical path structure | 0/d |
| Measurement aperture | 21mm,7mm |
| range | 0-100% |
| Haze resolution | 0.01% |
| Transmittance resolution | 0.01% |
| Haze Repeatability | φ 21mm diameter, within 0.05 (30 standard deviation differences for standard haze films with a test haze of about 40 at intervals of 5s) |
| Repeatability | ≤0.1% |
| Sample size | Thickness ≤ 145mm |
| store data | Mass Storage |
| screen | 7-Inch full-color touchscreen, Android Operating system |
| interface | USB port |
| Power Supply | DC12V |
| Operating temperature | 10~40 ℃, Relative Humidity 80% or less (at 35 ℃), no water condensation |
| Storage temperature | -20 ℃~ 50 ℃, Relative Humidity 80% or less (at 35 ℃), no water condensation |
| Volume | Length X width X height: 310mmX215mmX540mm |
| Standard | PC management software (Haze QC) |
| optional | Measurement fixture, haze standard sheet, 5/10mm custom diameter plate, 40 * 10 Colorimetric dish |
CHNSpec TH-110 haze Meter Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 44572-2024
- IncomingGB/T 19787-2025
- ActiveJJF 1303-2011
- ActiveJIS
- ActiveGB/T 2566-2010
- ActiveGB/T 10002.2-2023
- ActiveGB/T 27740-2011
- ActiveGB/T 10003-2008
- ActiveGB/T 4456-2008
- ActiveASTM D1003-2021
- ActiveHG/T 5065-2016
- ActiveGB/T 2680-2021
- ActiveHG/T 5297-2018
- ActiveHG/T 5076-2016
- ActiveHG/T 5299-2018
- ActiveGB/T 2410-2008
- ActiveGB/T 2005-19787


TH-110