NELE DC-2010 Thermostatic Bath vertical 10L/-20 ℃ +/- 0.05 ℃
-20~100 ℃, Temperature uniformity +/- 0.05 ℃, working tank size 275 * 195 * 180mm, working tank volume 10L, groove opening size 180 * 140mm, cooling capacity 1600W@20 ℃, pump Flow rate 13L/min, circulation external circulation.
Nele-
Shangtian Jingyi DC-0520N (0.01) Thermostatic Bath Laboratory Thermostatic Water Bath -5 ℃/20L
$ 1734.00 -
NELE DC-3015 Thermostatic Bath Vertical 15L/-30 ℃ +/- 0.05 ℃
$ 1563.00 -
FANGRUI HDC0515 Constant Temperature Circulating Bath, temperature range -5~ 100 ℃
$ 790.00 -
YIHENG DKB-600B electric thermostatic circulating Water Tank with electromagnetic pump, volume 30L
$ 444.00 -
SANFA DKU-305 Thermostatic Oil Bath 300 ℃/ +/- 0.5 ℃
$ 599.00
The high-precision low-temperature constant temperature bath adopts a fluorine-free refrigeration system, and the main components are directly imported, with stable and reliable performance. Widely used in petroleum, chemical industry, electronic instrumentation, physics, chemistry, bioengineering, medicine and health, life science, light industry food, physical property testing and chemical analysis and other research departments, colleges and universities, enterprise quality inspection and production departments, to work for users Provide a liquid environment with controlled heat and cold, uniform and constant temperature, and directly conduct constant temperature tests or tests on test samples or produced products in the tank, which can be used for direct heating or cooling, as a temperature source for auxiliary heating or cooling, such as for reactions Kettle, automatic synthesis equipment, extraction and condensation device temperature control.
technical features
Fully enclosed environmental protection compressor refrigeration system, no CFC.
Temperature range: optional -60~100°C (medium choose pure water, ethylene glycol, alcohol, etc. according to the temperature range);
Temperature control function: Built-in a new generation of integrated PID automatic temperature control program, built-in the highest precision PT100 temperature sensor 1/3B level. Equipped with a large and bright LCD, the resolution of the digital display in Chinese and English is 0.01°C, ensuring accurate and stable temperature control.
Capacity range: 6L, 10L, 15L, 20L, 30L, 50L, 100L, and non-standard products can also be designed and produced completely according to user requirements.
Internal circulation function: Adopt a heatless centrifugal circulation pump to avoid the influence of the traditional water pump on the temperature field of the tank due to its own heat production. The internal circulation system is designed on the principle of porous U-shaped reflux circulation, which realizes the turbulence and high uniformity of the flow field and temperature field in the tank.
The shell of the fuselage adopts anti-aging electrostatic spray technology, and the liner and table are made of high-quality S304 brushed stainless steel.
The fine workmanship of the front panel and table top of the chassis, coupled with the unique humanized R rounded corner design structure, can prevent operators from being injured by edges and corners inadvertently.
The water release system can meet the needs of various laboratories and enterprises for liquid replacement.
Safety protection device:
1. With power-off protection function
2. With upper and lower limit temperature alarm setting function
3. Low water level protection and alarm function
4. Temperature runaway protection and alarm function
5. The heating device has low water level anti-dry and explosion-proof functions
6. Multiple protection functions for compressor overheating and overcurrent
DC series model
| model | temperature range | Tank Capacity | Cooling capacity |
| DC0506 | -5~100 | 6 | 600 |
| DC0510 | -5~100 | 10 | 900 |
| DC0515 | -5~100 | 15 | 1500 |
| DC0520 | -5~100 | 20 | 2000 |
| DC0530 | -5~100 | 30 | 2700 |
| DC0550 | -5~100 | 50 | 4000 |
| DC05100 | -5~100 | 100 | 7000 |
| DC1006 | -10~100 | 6 | 800 |
| DC1010 | -10~100 | 10 | 1200 |
| DC1015 | -10~100 | 15 | 1800 |
| DC1020 | -10~100 | 20 | 2300 |
| DC1030 | -10~100 | 30 | 3000 |
| DC1050 | -10~100 | 50 | 4300 |
| DC10100 | -10~100 | 100 | 7500 |
| DC2006 | -20~100 | 6 | 1200 |
| DC2010 | -20~100 | 10 | 1600 |
| DC2015 | -20~100 | 15 | 2200 |
| DC2020 | -20~100 | 20 | 2700 |
| DC2030 | -20~100 | 30 | 3400 |
| DC2050 | -20~100 | 50 | 4700 |
| DC20100 | -20~100 | 100 | 7900 |
| DC3006 | -30~100 | 6 | 1700 |
| DC3010 | -30~100 | 10 | 2100 |
| DC3015 | -30~100 | 15 | 2700 |
| DC3020 | -30~100 | 20 | 3200 |
| DC3030 | -30~100 | 30 | 3900 |
| DC3050 | -30~100 | 50 | 5200 |
| DC30100 | -30~100 | 100 | 8400 |
| DC4006 | -40~100 | 6 | 2300 |
| DC4010 | -40~100 | 10 | 2900 |
| DC4015 | -40~100 | 15 | 3400 |
| DC4020 | -40~100 | 20 | 3900 |
| DC4030 | -40~100 | 30 | 4600 |
| DC4050 | -40~100 | 50 | 5800 |
| DC40100 | -40~100 | 100 | 9000 |
| DC5006 | -50~100 | 6 | 2700 |
| DC5010 | -50~100 | 10 | 3400 |
| DC5015 | -50~100 | 15 | 3900 |
| DC5020 | -50~100 | 20 | 4500 |
| DC5030 | -50~100 | 30 | 5200 |
| DC5050 | -50~100 | 50 | 6400 |
| DC50100 | -50~100 | 100 | 9800 |
| DC6006 | -60~100 | 6 | 3500 |
| DC6010 | -60~100 | 10 | 4200 |
| DC6015 | -60~100 | 15 | 4700 |
| DC6020 | -60~100 | 20 | 5300 |
| DC6030 | -60~100 | 30 | 6000 |
| DC6050 | -60~100 | 50 | 7200 |
| DC60100 | -60~100 | 100 | 10600 |
| Other parameters | |||
| temperature resolution | 0.01°C | ||
| temperature uniformity | ±0.05℃ | ||
| External circulation pump flow | 13L/min | ||
| When the cooling capacity is pure water at 20°C | |||
| Unit: °C, L, W | |||
Optional function
1. An optional extended external PT100 temperature sensor can detect and control the temperature of the external system in real time during external circulation.
2. Optional built-in 1~30 segment temperature control program or uniform speed program temperature control, automatic program temperature control, real-time display of the set temperature-time program running status.
3. Optional RS232 or RS485 communication interface, easy to connect to the host computer, with ModbusRTU communication protocol.
4. The optional design and installation of a magnetic stirring system can directly carry out magnetic stirring on the liquid samples placed in the beakers in the working chamber of the constant temperature tank, without the need for an external vertical mixer, reducing redundant operations.
5. The built-in cooling coil in the tank can be selected to quickly cool down and control the exothermic reaction of the system.
6. An optional height-adjustable immersion loading platform can easily adjust the liquid level of the immersed sample.
7. Horizontal shape can be selected, which has the characteristics of compact structure, lower center of gravity, and strong stability.
Nele DC-2010 (Vertical) Thermostatic BathSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | -20~100℃ |
| Temperature Uniformity | ±0.05℃ |
| Tank Size | 275*195*180mm |
| Tank Volume | 10L |
| Tank opening Dimensions | 180*140mm |
| Cooling Capacity | 1600W@20℃ |
| Pump flow | 13L/min |
| Circular mode | External circulation |
Nele DC-2010 (Vertical) Thermostatic Bath Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 2019-2022
- ActiveJJF 1030-2023
- ActiveGB/T 26809-2011
- ActiveGB/T 32710.3-2016
- ActiveJJF 1030-2010
- ActiveGB/T 26808-2011
- ActiveJB/T 5376-1991


DC-2010 (Vertical)
DC-2010 (horizontal)