CHINA high-low temperature Humidity Cyclic Chamber NBC-LHS-100L constant temperature and Humidity Test Chamber -40~150 ℃/100L
Volume 100L, temperature control -40 ℃~ 150 ℃, Temperature fluctuation ≤ ± 0.5 ℃, 304 stainless steel outer box, LCD touch screen operation, programmable control.
HuiTai-
YIHENG BPS-100CA constant temperature and Humidity Test Chamber -20~100 ℃/100L
$ 4257.00 -
CHINA NBC-100L-40 Programmable High and Low Temperature Humidity chamber -40 ℃~ 150 ℃
$ 2687.00 -
KESIONOTS KS-HW80D programmable constant temperature and humidity environmental chamber -40~ 150 ℃/80L
$ 4703.00 -
CHINA NBC-408L-20 Programmable Reliability Environmental Test Chamber Paint Panel -20 ℃/408L
$ 3610.00 -
HZAOC GDJS-010C high-low temperature Humidity Cyclic Chamber -40~150 ℃/1000L
$ 12119.00











Introduction
The function of the Test Chamber is to provide a test environment such as constant high-low temperature humidity and alternating high-low temperature humidity; Including refrigeration system, heating system, humidification/water system, air duct system, control system, system protection device, etc.
Constant temperature and humidity testing machine, also known as environmental testing machine, can accurately simulate low temperature, high temperature, high temperature and high humidity, low temperature and low humidity and other complex natural environments, suitable for electronics, electrical appliances, batteries, plastics, food, paper products, vehicles, metals, chemicals, building materials, research institutes, inspection and quarantine bureaus, universities and other industry units for quality control testing.
Test chamber body
1. Structural form
The integral structure, that is, the Test Chamber, the refrigeration system, the heating/humidification system, the air conditioning system, the electrical control cabinet, and the refrigeration unit are a whole, the refrigeration unit is located at the bottom of the box, and the electrical control part is placed on the side of the Test Chamber for easy operation.
2. a box
a) In the air duct mezzanine at one end of the studio, heat/humidifier, refrigeration evaporator, blower motor, fan blade and other devices are distributed; b) The Test Chamber workshop is made of 1mm thick SUS304 stainless steel plate, and enclosure is made of 1mm thick stainless steel.
Meet the criteria
GB11158、GB10589-89、GB10592-89、GB/T10586-89、GB/T2423.1-2001、GB/T2423.2-2001、GB/T2423.3-93、GB/T2423.4-93、GB/T2423.22-2001、IEC60068-2-1.1990、IEC60068-2-2.1974、GJB150.3、GJB150.4、GJB150.9etc.
Test chamber refrigeration system
Refrigeration principle
The refrigeration part is the main part of the cold source generated by the equipment, which provides the required cooling capacity for the cooling, low temperature and constant temperature of the equipment, and the refrigeration system is automatically turned on according to the different test states of the equipment to provide cooling capacity for the corresponding test process, so as to achieve the purpose of the performance indicators of the equipment.
Refrigeration system components
1. Compressor:The refrigeration system is mainly a compressor, this scheme we use the French Taikang fully enclosed compressor, 2.2, oil separator: whether the compressor has refrigeration oil, will directly affect its life
3. Condensing evaporator:Adopting the Swedish "Alfa Laval" currently in the world
4. Vibration reduction:Compressor spring vibration reduction is adopted, and the overall secondary vibration reduction of the refrigeration system is adopted;
5. Refrigeration evaporator:The evaporator is located in the air duct interlayer at one end of the Test Chamber and is forced to ventilate by a blower motor
Touch controllers
1. LCD touch panel, screen intercom input data, temperature and humidity can be programmed at the same time
2. It can display the curve, display the set value curve, and the actual running curve;
3. Programmable, program group up to 120 groups;
4. The interface between Chinese and English can be converted;
5. It has the function of date and time adjustment, scheduled start, shutdown and screen lock.

HuiTai NBC-LHS-100L Humidity Test ChamberSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | -40~150℃ |
| Temperature fluctuation | ±0.5℃ |
| Temperature Uniformity | ≤±2℃ |
| Humidity control range | 20~98%R.H |
| Input power | 3.5Kw |
| Power | Single phase 220V 50HZ |
| Interior size | 400*500*500mm |
| Dimensions | 1080*1450*1100mm |
| Interior Volume | 100L |
| Noise | ≤65dB |
| wind speed | 1.7~2.5m/s |
| Humidity Deviation | ≤3% |
| Heating rate | RT + → 150 ℃ │ 40min (no-load nonlinear) |
| Cooling rate | RT + → -40 ℃ │ 60min (no-load nonlinear) |
| Humidity fluctuation | 3%R.H |
| Inner box material | SUS304 stainless steel |
| Enclosure Material | Stainless steel plate atomized (SUS #304) or cold plate paint (optional) |
| Thermal insulation material | Rigid Polyurethane Foam and Glass Cotton |
| Window size | 260X340x40mm 3-layer vacuum layer |
| Refrigeration system | Fully dense compressor imported from France |
| refrigerant | Environmentally friendly refrigerant R404A |
| Condenser | Fin type with cooling motor |
| Condenser | Fin type multi-stage automatic load Capacity adjustment |
| Display | Full Chinese LCD 7-inch 880 display LCD touch panel |
| Environment humidity | Not more than 85% |
| Humidity Control Accuracy | ±1%R.H |
| Controller Resolution | Temperature ± 0.1, Humidity 1% R.H. |
| Controller temperature slope | 0.1~ 9.9 can be set |
| Safety Devices | Upper and lower limit standby and alarm functions |
| Temperature and humidity input signal selection | PT 100Ω × 2 (dry and wet bulbs) |
| Temperature and humidity conversion output | 4~20MA |
| Controller | 6 groups of P.I.D control parameter setting, P.I.D automatic calculation, dry and wet bulb automatic correction |
| Display function | Screen direct display options, direct display of temperature and humidity settings (SV) and actual (PV) values (in English), current execution program number, segment number, remaining time and cycle number |
| Display function 2 | Running accumulated time function, temperature and humidity program settings are displayed in graphic Linear dispersion, with real-time display program Linear dispersion execution function |
| Available program groups | Up to 100 groups |
| Available memory Capacity | Total 5000SEGMENTS |
| Command, repeability | Each command can be up to 9999 times |
| SEGMENTS time setting | 0~530Hour59Min |
| Display when the program is executed | Real-time display of graphical Linear dispersion |
| Miscellaneous function | With date, time adjustment function, button and screen lock (LOCK) function |
| temperature control Accuracy | ±0.1℃ |
HuiTai NBC-LHS-100L Humidity Test Chamber Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- The Critical Study of Coating Specimen State Adjustment and Test Temperature Humidity
- Damp heat testing chamber and low-Temperature Test Chamber
- ActiveJJF 1564-2016
- ActiveJJF 1270-2010
- ActiveJJF 1101-2019
- 2058-2023
- ActiveGB/T 43489-2023
- ActiveGB/T 38948-2020
- AbolishGB/T 2424.5-2006
- AbolishGB/T 2423.34-2012
- ActiveGB/T 2423.50-2012
- ActiveGB/T 11158-2008
- ActiveIEC 60068-2-1-1990
- ActiveGB/T 2423.22-2002
- ActiveGB/T 2423.4-2008
- AbolishGB/T 2423.34-2005
- AbolishGB/T 2423.25-2008
- ActiveQB/T 5250-2018
- ActiveGJB 150.9A-2009
- ActiveGB/T 2423.3-2016
- ReplacedGB/T 10592-2008
- ActiveGB/T 10586-2006


NBC-LHS-100L