      Eddy Current, split probe, range 0-1500um, error range +/- (2% of reading + 0.3um); minimum substrate thickness 0.05mm; data statistics function; zero and multi-point calibrated; measurable small size/profiled material.

      Brand
      SKU: NB034870
      China LinShang
      Stock
      Loading…
      Price
      $ 590.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • LinShang LS225+N1500 Coating Thickness GaugeOverview

        • Specifications
        • Comments
        • FAQs
        LS225+N1500
        Coating Thickness Gauge
        • LINSHANG LS225 Coating Thickness Gauge with N1500 probe
        • LINSHANG LS225 Coating Thickness Gauge with N1500 probe Figure 1
        • LINSHANG LS225 Coating Thickness Gauge with N1500 probe Figure 2
        Eddy Current, split probe, range 0-1500um, error range +/- (2% of reading + 0.3um); minimum substrate thickness 0.05mm; data statistics function; zero and multi-point calibrated; measurable small size/profiled material.

        Introduction

        The LS225+N1500 is a split aluminum-based coating Thickness Gauge consisting of the host LS225 and non-ferrous probe N1500. The instrument adopts the principle of vortex flu response, with ultra-high measurement accuracy and repeatability, and is equipped with a probe-type probe design, which is especially suitable for measuring ultra-thin coating and various small-sized workpieces and special-shaped materials.

        It is mainly used for the anodizing layer on the surface of aluminum alloy profiles, aluminum plates, aluminum-plastic panels and various aluminum workpieces, as well as the thickness measurement of non-conductive coatings on non-ferrous metal substrates such as brass and copper.

        Product structure diagram

        Detail Figure 1 of Linshang LS225+N1500 Aluminum-based Coating Thickness Gauge

        Hayashi LS225+N1500 Aluminum-based Coating Thickness Gauge Detail Figure 2

        The product is based on the standard

        GB/T 4956-2003 Thickness measurement of non-magnetic overlay on magnetic substrate - Magnetic method

        DIN ENISO2808 Determination of paint film thickness for coatings and varnishes

        JJG-818-2005 V. R. of Magnetic and Eddy-current Coverage Thickness Measuring Instrument

        Features

        (1) The probe type probe design is especially suitable for measuring the coating thickness on small size and special-shaped materials.

        (2) Using digital oscillation technology and high-speed ADC acquisition, it can measure ultra-thin coating layers below 10μm and ensure accurate and stable data.

        (3) The digital probe is adopted, and the digital signal is processed on the probe, which is not easy to be disturbed by the external environment and ensures good data repeatability.

        (4) It has an ultra-wide range of 0-1500μm, and the measurement unit μm and mil can be switched.

        (5) The special hand pressure test rack can eliminate the error caused by human factors, and the data repeatability can reach 0.1μm

        (6) Support zero adjustment and multi-point calibration to ensure more accurate data, equipped with special zero adjustment board and standard piece.

        (7) It has the function of data statistics, and automatically counts the maximum, minimum, average value and variance value of the last 9 groups of data.

        (8) The use of high hardness probe and increased durability design can ensure that the instrument has a long service life.

        (9) It has the function of automatic shutdown without operation (can be set for 1-9 minutes), and Chinese and English interfaces can be switched freely.

        Hayashigami LS225+N1500 Aluminum-based Coating Thickness Gauge Details Figure 3

        Application

        LS225+N1500 aluminum-based coating Thickness Gauge can be used for rapid and non-destructive measurement of the thickness of non-conductive coating on non-magnetic metal substrates in production inspection, construction acceptance and sales exhibition sites, and can be applied to aviation, building materials, machinery, chemical, light industry and instrumentation industries.

        Detail Figure 4 of Linshang LS225+N1500 Aluminum-based Coating Thickness Gauge

        VS

        LinShang LS225+N1500 Coating Thickness GaugeSpecifications

        LIST VALUE
        host display 240 × 160 dot matrix LCD
        Power Supply 4 1.5VAAA alkaline batteries
        Operating temperature 0℃~50℃
        Storage temperature -20~60℃
        Host size Length 148mmX Width 76mmX Thickness 26mm
        Weight 194G (including battery)
        Measurement principle Eddy Current
        matrix material Non-ferrous magnetic metal
        Measurement range 0~1500μm
        Resolution 0.1μm|1μm|0.01mm
        Repeatability ≤ +/- ( 0.8% reading + 0.1μm) hand pressure testing device
        margin of error ±2%
        Unit display μm/mil
        Measurement interval 0.8s
        Minimum measurement surface Φ7mm
        Minimum radius of curvature Convex 1.5mm, Concave 10mm
        Minimum substrate thickness 0.05mm
        User calibrated Support zero point calibrating, 1 point to 5 point calibrating
        Probe size Φ15*110mm
        Probe Weight 81g

        LinShang LS225+N1500 Coating Thickness Gauge Packing list

        Host x1, N1500 probe x1, zero adjustment board x1, standard piece x7, manual x1, certificate/quality assurance card x1, 1.5V AAA alkaline battery x4, plastic engineering box x1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Under what circumstances does the paint film instrument need to be zeroed?
        [A]
        The following situations need to be used after zero adjustment of the two iron and aluminum zero adjustment plates: 1. The test zero board does not display 0.0. 2. Unable to identify iron galvanized, iron powder putty or errors in identification. 3. When you feel that the test data is inaccurate.
        LinShang
        LINSHANG LS225 Coating Thickness Gauge with N1500 probe
        Service
        Focus on online sales of Lab Testing Instruments