LINSHANG LS225 Coating Thickness Gauge with N1500 probe
Eddy Current, split probe, range 0-1500um, error range +/- (2% of reading + 0.3um); minimum substrate thickness 0.05mm; data statistics function; zero and multi-point calibrated; measurable small size/profiled material.
LinShang-
Qnix Fe/NFe 1.2mm Dual Function Thickness Probe for magnetic Induction and eddy Current 1250μm
$ 1033.00 -
German EPK probe F1.6/90 Thickness Gauge probe, extended 6mm line, thickness measurement range 0~1600um
$ 2541.00 -
German EPK MiniTest 600 B-FN coated platings Thickness Gauge, iron-based/non-iron-based
Login -
QNix P3 Coating Thickness Gauge
$ 201.00 -
Defelsko PosiTector 6000 FS1 Coating Thickness Gauge Iron metal substrate (such as steel) nonmagnetic coating
$ 966.00
Introduction
The LS225+N1500 is a split aluminum-based coating Thickness Gauge consisting of the host LS225 and non-ferrous probe N1500. The instrument adopts the principle of vortex flu response, with ultra-high measurement accuracy and repeatability, and is equipped with a probe-type probe design, which is especially suitable for measuring ultra-thin coating and various small-sized workpieces and special-shaped materials.
It is mainly used for the anodizing layer on the surface of aluminum alloy profiles, aluminum plates, aluminum-plastic panels and various aluminum workpieces, as well as the thickness measurement of non-conductive coatings on non-ferrous metal substrates such as brass and copper.
Product structure diagram


The product is based on the standard
GB/T 4956-2003 Thickness measurement of non-magnetic overlay on magnetic substrate - Magnetic method
DIN ENISO2808 Determination of paint film thickness for coatings and varnishes
JJG-818-2005 V. R. of Magnetic and Eddy-current Coverage Thickness Measuring Instrument
Features
(1) The probe type probe design is especially suitable for measuring the coating thickness on small size and special-shaped materials.
(2) Using digital oscillation technology and high-speed ADC acquisition, it can measure ultra-thin coating layers below 10μm and ensure accurate and stable data.
(3) The digital probe is adopted, and the digital signal is processed on the probe, which is not easy to be disturbed by the external environment and ensures good data repeatability.
(4) It has an ultra-wide range of 0-1500μm, and the measurement unit μm and mil can be switched.
(5) The special hand pressure test rack can eliminate the error caused by human factors, and the data repeatability can reach 0.1μm
(6) Support zero adjustment and multi-point calibration to ensure more accurate data, equipped with special zero adjustment board and standard piece.
(7) It has the function of data statistics, and automatically counts the maximum, minimum, average value and variance value of the last 9 groups of data.
(8) The use of high hardness probe and increased durability design can ensure that the instrument has a long service life.
(9) It has the function of automatic shutdown without operation (can be set for 1-9 minutes), and Chinese and English interfaces can be switched freely.

Application
LS225+N1500 aluminum-based coating Thickness Gauge can be used for rapid and non-destructive measurement of the thickness of non-conductive coating on non-magnetic metal substrates in production inspection, construction acceptance and sales exhibition sites, and can be applied to aviation, building materials, machinery, chemical, light industry and instrumentation industries.

LinShang LS225+N1500 Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| host display | 240 × 160 dot matrix LCD |
| Power Supply | 4 1.5VAAA alkaline batteries |
| Operating temperature | 0℃~50℃ |
| Storage temperature | -20~60℃ |
| Host size | Length 148mmX Width 76mmX Thickness 26mm |
| Weight | 194G (including battery) |
| Measurement principle | Eddy Current |
| matrix material | Non-ferrous magnetic metal |
| Measurement range | 0~1500μm |
| Resolution | 0.1μm|1μm|0.01mm |
| Repeatability | ≤ +/- ( 0.8% reading + 0.1μm) hand pressure testing device |
| margin of error | ±2% |
| Unit display | μm/mil |
| Measurement interval | 0.8s |
| Minimum measurement surface | Φ7mm |
| Minimum radius of curvature | Convex 1.5mm, Concave 10mm |
| Minimum substrate thickness | 0.05mm |
| User calibrated | Support zero point calibrating, 1 point to 5 point calibrating |
| Probe size | Φ15*110mm |
| Probe Weight | 81g |
LinShang LS225+N1500 Coating Thickness Gauge Packing list
Host x1, N1500 probe x1, zero adjustment board x1, standard piece x7, manual x1, certificate/quality assurance card x1, 1.5V AAA alkaline battery x4, plastic engineering box x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveISO
- ActiveGB/T 44757-2024
- ActiveJB/T 13939-2020
- ActiveQJ 990.3A-2011
- ReplacedNF EN ISO 2808-2007
- ActiveGB/T 13448-2019
- ActiveJJG 818-2018
- ActiveGB/T 1727-2021
- ActiveGB/T 12967.1-2020
- ActiveHG/T 20720-2020
- ActiveASTM B244-2021
- AbolishGB/T 13448-2006
- ActiveGB/T 4957-2003


LS225+N1500
LS225 + F500
LS225 + N1500 + Rack
LS225 + F500 + Rack
LS225
LS225-PFS