Fungilab V-compact R Rotational Viscometer Viscosimeter 40 million cP
Measurement range 25~ 40000000mPa · s, Rotor speed 0.01~ 250rpm, Repeatability +/- 0.2% F.S, Measurement accuracy +/- 1% F.S, Temperature range -40~ + 300 ℃, Temperature resolution 0.1 ℃, Temperature accuracy +/- 0.3 ℃, temperature sensor PT100, Class A, Rotor material All rotors are made of AISI 316 stainless steel, Power supply Voltage 90-240VAC, 50/60HZ.
Fungilab-
HuiNuo NDJ-5S + micro printer rotational viscometer Viscosimeter
$ 405.00 -
NIRUN NTV-P3RV Digital Viscometer Fluid Viscosity Tester 40M mpa.s
$ 5027.00 -
Ander NDJ-5S Digital Viscometer Viscosity Range 10mPa·s~ 100.000Pa · s
$ 568.00 -
HBDV-2T Rotational Viscometer Viscosity 800~320 million mPa·s
$ 2148.00 -
FANGRUI SNB-2 Digital Rotational Viscometer Viscosity range 1~ 6 million cp
$ 556.00
Data shows
Rotational speed: r.p.m or S-1
Viscosity: cP, P, mPa.s, Pa.s, cSt, St, mm²/s
Percentage of full scale: %
Sample temperature: °C or OF
Shear velocity (SR): S-1
Shear stress (SS): N/m2, Pa, Dyne/m2
Density (customer input required): g/cm³ or Kg/m³
Note: The shear stress and shear rate can only be displayed when the coaxial rotor L2C+L3C is matched
Viscosity measurement
Dynamic viscosity (cp or mPas)
Kinematic viscosity (cSt) (the customer is required to enter the sample density value in advance before viscosity measurement)
Procedure measurements
Multi-step program measurement modes can be used and edited;
Programs can be stored for quick recall later;
TTT (Stop Measurement at a Certain Torque Reach) and TTS (Stop Measurement at a Certain Time Limit) measurement modes, multi-step measurement, and slope measurement are selectable.
Data Storage
All test data will be stored in a comprehensive database;
Quality Control Line (QCL) alarms and over-range alarms can be activated or deactivated;
The user has access to the program parameters for each measurement experiment.
Customer-defined
Customer can create measured rotational speeds (0.01 to 250 rpm);
Quality Control Line (QCL) alarms and over-range alarms can be activated or deactivated;
The customer can customize the horizontal and longitudinal coordinates on the measurement curve.
Self-test function: Viscometer self-test function, sound and light alarm reminder
Measuring function: When a combination of transrot and speed is selected, the maximum range for that combination is automatically calculated
Tablet control: All parameters can be modified via an 8-inch tablet, and the mobile app is available for free in the Google Play Store
language: Multiple Chinese languages are optional
QCL: Select and set the sample quality inspection line
I.A.M.: Data measurement and upload time can be adjusted
Graphics mode: Display experimental data with real-time charts
Report export: Test results are exported in PDF and CSV formats
calibration: Allows the user to enable viscosity and temperature calibration (this calibration is reset to factory calibration)
offset: Adjust the temperature by offset
Heldal(V-COMPACT only): Spiral viscosity measurement mode for non-Newtonian fluid samples
annex: Small Sample Adapter (APM) and Low Viscosity Adapter (LCP) are optional
PPR: Rotor quick-release device
Technical Specifications:
Repeatability: 0.2%
Accuracy: ±1% of full scale
Temperature range: -40°C ~+300°C
Temperature resolution: 0.1°C
Temperature accuracy: ±0.3°C
Temperature probe: PT100, Class A
All rotors are made of AISI 316 stainless steel
Power supply: 90-240VAC, 50/60HZ
Standard configuration
8-inch tablet (viscosity measurement app installed), standard rotor (4 standard rotors for L type, 6 standard rotors for R and H models), measuring unit (L or R or H), automatic base, rotor protective case, rotor holder, temperature probe, power cord, calibration certificate, operating manual and carrying case.
Optional
Small sample volume sample adapter APM, low viscosity sample adapter LCP, high viscosity sample adapter Heldal, standard silicone oil, Water Bath, universal adapter, PPR quick release system (V-PAD optional), double-layer temperature controlled beaker (V-PAD optional), paddle rotor (yield stress), cone plate system.
V-PAD viscosity measurement range
| Order number | Model | Measuring range (cp) | Speed range (rpm) |
| VC101003 | V-COMPACT L | 1*-6.000.000 | 0.01-250 |
| VC101002 | V-COMPACT R | 25**-40.000.000 | 0.01-250 |
| VC101001 | V-COMPACT H | 200***-320.000.000 | 0.01-250 |
* For viscosities ranging from 0.1 to 200RPM, it is recommended to use LCP adapters; The lowest viscosity measured without a matching LCP adapter is 15CP
** The recommended speed for the R-1 rotor is 60rpm (higher speed measurements will be unstable)
The recommended speed for the R-1 rotor is 60 rpm
Resolution measured according to viscosity range
| Viscosity value | resolution |
| 100 cp | 0.01cp |
| 1.000cp | 0.1cp |
| 5.000cp | 1.0cp |
| 10.000cp | 5.0cp |
| 25.000cp | 10.0cp |
| 50.000cp | 25.0cp |
| 100.000cp | 100.0cp |
| 1000.000cp | 1000.0cp |
Fungilab V-compact R Rotational ViscometerSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | 25~40000000mPa·s |
| Rotor speed | 0.01~250rpm |
| Repeatability | ±0.2%F.S |
| Measurement Accuracy | ±1%F.S |
| Temperature range | -40~+300℃ |
| Temperature Resolution | 0.1℃ |
| Temperature Accuracy | ±0.3℃ |
| temperature sensor | PT100, Class A |
| Rotor material | All rotors are made of AISI 316 stainless steel |
| Power supply Voltage | 90-240VAC,50 / 60HZ |
Fungilab V-compact R Rotational Viscometer Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


V-compact R