Bante PHS-500C Mixing pH Meter pH mV Temperature, Timing, Stirring, Ceramic Plate
pH mV temperature, timing, stirring Measurement range 0.00~14.00pH, +/- 1999mV, 0~100 ℃, stirring capacity 0~2000mL, stirring speed 0~1250rpm, automatic temperature compensation, working panel material ceramic.
Bante-
FANGZHOU FZ-833 Strong acid PH electrode with temperature probe, can measure ≤ 1wt% concentration of hydrofluoric acid solution
$ 287.00 -
HANNA HI98127 pH Measurement Instrument - 2.0~16.0pH
$ 286.00 -
LEICI PHS-2F precision acidity meter mV + PH 0.02 grade
$ 292.00 -
LEICI E-201-P planar pH composite electrode
$ 103.00 -
HANNA HI981401N pH Determination Controller, Suspended
$ 319.00
Features
• Classic laboratory pH meter with white backlit LCD display.
• Optional USA or NIST standard buffer group, in line with the standards used in different countries.
• Automatic electrode slope display, prompting the current condition of the sensor.
• Automatic or manual temperature compensation to improve the measurement accuracy of the instrument.
• Intelligent mixing design, automatic speed up from slow to fast.
Standard configuration
• pH electrodes
• Straight-pull electrode holder
• Tie-rod electrode holder
• pH standard buffer reagent (pH4.01/7.00/10.01)
• stir bar

Bante PHS-500C Stirring acidity MeterSpecifications
| LIST | VALUE |
|---|---|
| PH range | 0.00~14.00pH |
| PH measurement Accuracy | ±0.01pH |
| PH calibrated | 2 point (pH4.01/6.86/9.18) |
| mV range | ±1999mV |
| mV measurement Accuracy | 1mV |
| Temperature Measurement range | 0~100℃ |
| Temperature display resolution | 0.1℃ |
| Temperature measurement Accuracy | ±0.5℃ |
| Capacity | 0~2000mL |
| Stirring speed | 0~1250rpm |
| Working panel size | 135×135mm |
| Work panel material | Pottery and porcelain |
| Timing working interval | 0~999 minutes |
| Temperature compensation range | 0~100 ℃, automatic |
| Connector | BNC |
| Power Type | AC 220V/50Hz |
| Dimensions | 210×205×75mm |
| Gauge Weight | 1.5kg |
Bante PHS-500C Stirring acidity Meter Packing list
Host X1, manual X1, certificate X1, warranty card X1, bracket X2, granule X3, stirringrod X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 3324-2024
- ActiveGB/T 44332-2024
- ActiveGB/T 2394-2024
- ActiveJJF 1575-2016
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveSN/T 1523-2005
- ActiveQB/T 2724-2018
- ActiveJB/T 6203-2017
- ActiveNY/T 82.7-1988
- Active 098-2007
- ActiveGB/T 8077-2023
- ActiveGB/T 1601-2023
- ActiveGB/T 6920-1986
- ActiveGB/T 13580.4-1992
- AbolishGB/T 1601-1993
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 12010.4-2010


PHS-500C