INESA SHANGFEN L9 Dual beam of light UV-Visible Spectrophotometer
SHANGFEN L9 dual beam of light UV-Visible Spectrophotometer metering method dual beam of light, monochromator Czerny - Turner, focal length 200mm, grating 1600 lines/mm, L9 dual beam of light UV-Visible Spectrophotometer with USB communication port, can directly export data through U disk, standard 1cm Colorimetric dish holder.
ShangFen-
JINGHUA 756 UV-Visible Spectrophotometer 2nm Light spectrum Bandwidth 190-1100nm Wavelength range
$ 1781.00 -
YueFeng 754 Ultraviolet-visible spectrophoto-meter 195~ 1000nm Bandwidth 4.0nm
$ 786.00 -
JINGHUA 755B Automatic UV-Visible Spectrophotometer High Performance Grating, Large Sample Chamber
$ 1439.00 -
JINGHUA 756PC UV-Visible Spectrophotometer Wavelength range: 190nm~ 1100nm
$ 3149.00 -
YueFeng FSP6620 Flame Spectrophotometer Test Potassium/Sodium
$ 2092.00
Introduction
The L9 dual-beam UV-Vis Spectrophotometer adopts a new optical platform, 5 levels of adjustable bandwidth, ARM chip control and processing data, 8-inch color touch screen display menu, analysis map and data, and easy human-computer interaction. The instrument has the functions of photometry, spectral measurement, quantitative analysis, kinetic analysis, multi-wavelength measurement and so on. The products are used in product inspection, biochemistry, environmental monitoring, commodity inspection, petrochemical industry and other fields, and are the basic equipment required for quality control, technical appraisal and scientific research.
Features
The new optical platform enables the host of the instrument to have excellent optical performance and metering performance, low stray light and noise, high metering accuracy and stability.
The unique deuterium lamp and tungsten lamp installation, automatic light source switching and automatic finding of the center position of the Operating Mode, so that the user can operate the instrument and maintain the replacement light source more convenient, correct and safe.
Professional hardware and software design enables the instrument to have powerful spectral data processing and storage functions. Automatic scanning measurement spectra, multi-wavelength (1~3λ) determination, kinetic determination, 1~3 curve fitting, 1~4th derivative spectra, access to printed spectra and analysis data.
It adopts 8-inch color touch screen, good man-machine dialogue interface, and easy operation.
Imported long-life deuterium lamp and imported OSRAM tungsten lamp
With USB communication port, data can be exported directly through a USB flash drive, and a 1cm cuvette holder is standard.
Matching
UVwin8 ultraviolet spectroscopy software
5cm or 10cm cuvette holder
[L9 PAD] is equipped with a 10.1-inch tablet computer, which can realize wireless control, massive data storage and wireless data transmission of L9.
ShangFen L9 Dual beam of light UV-Visible SpectrophotometerSpecifications
| LIST | VALUE |
|---|---|
| Optical inspection system | Double beams of light |
| monochromator | Czerny - Turner |
| focal length | 200mm |
| grating line number | 1600 gr/mm |
| Detector | Import Detector |
| Light spectrum Bandwidth | 0.5nm、1nm、2nm、4nm、5nm |
| wavelength setting | touchscreen input |
| Wavelength range | 190~1100nm |
| Wavelength Precision | +/- 0.3Nm (measured ≤ +/- 0.2nm) |
| Wavelength Repeatability | ≤0.1nm |
| Scanning speed | Fast, medium, slow. |
| Light source switching wavelength | 340nm |
| stray light | ≤ 0.02% (NaI at 220 nm) (NaNO2 at 360 nm) |
| Photometric range | 0.0~200.0%T、-0.301~4.000A、0.000~9999C |
| Photometric Precision | ±0.3%T ±0.002Abs(0 ~ 0.5A) ±0.004Abs(0.5 ~ 1A) |
| Luminosity Repeatability | ≤0.15%T;0.001A(0~0.5A);0.002A(0.5~1A) |
| Baseline flatness | ≤ ±0.0008A |
| Noise level | 0.1%T |
| Baseline drift | 0.0003 (A/h) Measured at wavelengths of 250nm and 500nm (warm up for 2 hours on) |
| Power supply Voltage | AC220V±22V 50Hz±1Hz |
| Power | 200W |
ShangFen L9 Dual beam of light UV-Visible Spectrophotometer Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- What are the research methods for the properties of temperature-sensitive membranes?
- Contrast: Use a Spectrophotometer to determine the opacity of paints and coatings
- What is UV-Vis spectrophotometry used for and how does the measuring device work?
- Application of UV-Vis Spectrophotometer in Industry
- How to extend the service life of the aging Test Chamber?
- Which Spectrophotometer is widely used in the metal industry?
- Principle, characteristics and application of ultraviolet Spectrophotometer
- The difference between photometers at different angles
- Why is a Spectrophotometer calibrated? What is the principle?
- ActiveJJF 1641-2017
- ActiveJC/T 1040-2020
- ActiveSH/T 0409-1992
- ActiveSL 84-1994
- ActiveGB/T 6150.3-2023
- ActiveGB/T 6150.1-2023
- AbolishGB/T 14571.4-2008
- ActiveGB/T 14571.4-2022
- ActiveGB/T 36084-2018
- AbolishHJ/T 201-2005
- ActiveGB/T 13217.1-2020
- AbolishGB/T 11175-2002


L9