FANGZHOU FZ-600 two-in-one electrode conventional sample
FANGZHOU FZ-600 two-in-one electrode measurement range 0-14.00pH, temperature range 0-100 ℃, branch material plastic shell, reference structure single salt bridge, FZ-600 two-in-one electrode application range Conventional samples: common clear water samples, with a certain H + or OH- Ion concentration, good flowability.
FZchina-
Qiwei PHS-3C desktop precision pH meter Range 0~14pH
$ 129.00 -
FANGZHOU PHS-10 portable acidity meter pH/mV value and temperature value 0.01 grade
$ 306.00 -
HANNA HI7006L pH standard solution calibrated value: 6.86pH (25 ℃)
$ 121.00 -
FANGZHOU FZ-331 PH electrode waste water, emulsion suspension test
$ 167.00 -
PH value of hydrogen ion concentration measurement in aqueous solution by AOLILONG PHS-2C digital acidity meter
$ 126.00
LABOratory routine sample pH electrode series
| model | FZ-600T three-in-one electrode | FZ-600 two-in-one electrode | E-331 two-in-one electrode |
| Measuring range | 0-14.00pH | 0-14.00pH | 0-14.00pH |
| temperature range | 0-100℃ | 0-100℃ | 0-100℃ |
| Branch material | plastic case | plastic case | plastic case |
| Reference structure | single salt bridge | single salt bridge | single salt bridge |
| Reference type | Ag/Agcl | Ag/Agcl | Ag/Agcl |
| liquid junction | point sand core salt bridge | point sand core salt bridge | Sure-Flow |
| Sensitive film | Bulb | Bulb | Bulb |
| Filling fluid | not fillable | not fillable | not fillable |
| interface | BNC | BNC | BNC |
| Application | Routine samples: Common clear water samples with a certain concentration of H+ or OH- ions and good fluidity. | Routine samples: Common clear water samples with a certain concentration of H+ or OH- ions and good fluidity. | Routine samples: Common clear water samples with a certain concentration of H+ or OH- ions and good fluidity. |
FZchina FZ-600 Two-in-one electrodeSpecifications
| LIST | VALUE |
|---|---|
| PH range | 0~14.00pH |
| Temperature range | 0-100℃ |
| Branch pipe material | plastic shell |
| reference type | Single salt bridge |
| reference type | Ag/Agcl |
| hydraulic junction | Point core salt bridge |
| sensitive film | bulb |
| inner filling solution | non-padding |
| Connector | BNC |
| Application | Conventional samples: Common clear water samples with a certain H + or OH- Ion concentration and good flowability. |
FZchina FZ-600 Two-in-one electrode Packing list
Electrode X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveGB/T 6920-1986
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 2390-2013
- ActiveGB/T 14518-1993
- ActiveISO 19396-2-2017
- ActiveISO 19396-1-2017
- ActiveGB/T 21894-2008
- ActiveGB/T 7044-2022
- ActiveGB/T 23997-2009
- ActiveGB/T 6368-2008
- ActiveQB/T 2724-2005


FZ-600





