FANGZHOU FZ-620 Two-in-one electrode measurement Low Conductivity Detector sample
FANGZHOU FZ-620 two-in-one electrode measurement range 2-12.00pH, temperature range 5-90 ℃, branch material Glass shell, reference structure double liquid boundary, FZ-620 two-in-one electrode application range Suitable for measurement of low Conductivity Detector samples: Water sample lower conductivity, while H + or OH- Ion concentration is low.
FZchina-
HANNA HI2202 Bluetooth pH Flat Edge Measurement Instrument -2.00~16.00pH
$ 1140.00 -
HANNA HI1290 PICCOLO ® 2 pH Tester electrode
$ 192.00 -
LEICI E-201-CF pH composite electrode
$ 89.00 -
HANNA HI7004L pH standard solution calibrated value: 4.01pH (25 ℃)
$ 116.00 -
KeDiDa CT-1001C PH electrode with temperature probe NTC10K
$ 148.00
LABOratory Special Sample Electrode
| model | FZ-610 two-in-one electrode | FZ-620 two-in-one electrode | FZ-630 two-in-one electrode |
| Measuring range | 2-12.00pH | 2-12.00pH | 0-14.00pH |
| temperature range | 5-90℃ | 5-90℃ | 5-60℃ |
| Branch material | glass shell | glass shell | glass shell |
| Reference structure | Double fluid world | Double fluid world | single salt bridge |
| Reference type | Ag/Agcl | Ag/Agcl | Ag/Agcl |
| liquid junction | Cyclic PTFE bridge | Ceramic Sand Core Salt Bridge | Ceramic Sand Core Salt Bridge |
| Sensitive film | Bulb | Low Impedance Bulb | Bulb |
| Filling fluid | not fillable | can be filled | can be filled |
| interface | BNC | BNC | BNC |
| Application | Suitable for measuring samples with high-low ionic strength: acid rain, rainwater, tap water, seawater, supply water, distilled water, sewage. | Suitable for measuring low conductivity samples: water samples with low conductivity and low concentration of H+ or OH- ions, such as: measuring pure water and ultrapure water, water for injection, distilled water, sterilized purified water, soft surface water. | Suitable for measuring samples that are easy to block the electrode: the components in the sample have strong adhesion and very little water, and are easy to adhere to the surface of the glass bulb or reference salt bridge, such as: emulsion, food, cosmetics, pigments , paint, soil, sewage. |
| model | FZ-640 two-in-one electrode | FZ-650 two-in-one planar electrode | FZ-660 two-in-one electrode |
| Measuring range | 0-14.00pH | 0-14.00pH | 0-14.00pH |
| temperature range | 0-80℃ | 0-80℃ | 0-80℃ |
| Branch material | glass shell | plastic case | glass shell |
| Reference structure | double salt bridge | single salt bridge | double salt bridge |
| Reference type | Ag/Agcl | Ag/Agcl | Ag/Agcl |
| liquid junction | Annular Sand Core Salt Bridge | Sand core + PELLON salt bridge | Ring Sand Core Double Salt Bridge |
| Sensitive film | Bulb | short hair | Bulb |
| Filling fluid | can be filled | not fillable | can be filled |
| interface | BNC | BNC | BNC |
| Application | Suitable for measurement: samples containing protein, samples containing silver ions. | Ideal for pH measurement of solid and semi-solid soft, wet surfaces. Such as: agar medium, meat products, dough, paper, skin, cheese, jelly. | Suitable for organic sample measurement, special external reference filling liquid. |
| model | FZ-670 two-in-one electrode | FZ-680 two-in-one planar electrode | FZ-690 two-in-one electrode |
| Measuring range | 0-14.00pH | 0-14.00pH | 0-14.00pH |
| temperature range | 5-60℃ | 0-60℃ | 0-90℃ |
| Branch material | glass shell | plastic case | glass shell |
| Reference structure | single salt bridge | single salt bridge | double salt bridge |
| Reference type | Ag/Agcl | Ag/Agcl | Ag/Agcl |
| liquid junction | Ceramic Sand Core Salt Bridge | Annular Sand Core Salt Bridge | Ceramic Sand Core Salt Bridge |
| Sensitive film | Bulb | short hair | Bulb |
| Filling fluid | can be filled | not fillable | not fillable |
| interface | BNC | BNC | BNC |
| Application | Suitable for measuring mixed liquid samples: water samples have no precipitation after long-term storage, and have good fluidity, such as: fruit juice, beer, milk, blood protein, wine. | Ideal for pH measurement of solid and semi-solid soft, wet surfaces. Such as: agar medium, meat products, dough, paper, skin, cheese, jelly. | It is suitable for the measurement of strong acid, strong alkali and some organic samples. Such as: organic samples, according to organic samples with external salt bridge. |
FZchina FZ-620 Two-in-one electrodeSpecifications
| LIST | VALUE |
|---|---|
| PH range | 2~12.00pH |
| Temperature range | 5-90℃ |
| Branch pipe material | Glass shell |
| reference type | double liquid boundary |
| reference type | Ag/Agcl |
| hydraulic junction | Ceramic sand core salt bridge |
| sensitive film | Low Impedance Bulb |
| inner filling solution | Fillable |
| Connector | BNC |
| Application | Suitable for measurement of low Conductivity Detector samples: low conductivity of water samples, while low H + or OH- Ion concentration, such as: measurement of pure water and ultrapure water, water for injection, distillation water, sterilized purified water, soft surface water. |
FZchina FZ-620 Two-in-one electrode Packing list
Electrode X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 919-2023
- ActiveGB/T 6920-1986
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 2390-2013
- ActiveGB/T 14518-1993
- ActiveISO 19396-2-2017
- ActiveISO 19396-1-2017
- ActiveGB/T 7044-2022
- ActiveGB/T 23997-2009
- ActiveGB/T 6368-2008
- ActiveQB/T 2724-2005


FZ-620