BANTE S30-NH4 wireless Bluetooth ammonium Ion Meter 0.000005~ 1mol/L
Range 0.000005~ 1mol/L, Measurement accuracy +/- 0.5% F. S, with 2~ 5 point calibrated, manual temperature compensation, automatic end point lock, calibrated expiration reminder.
Bante-
LEICI 214-01 type antimony electrode BNC (Q9 type)
$ 94.00 -
HANNA HI729 Fluoride LR Tintometer
$ 192.00 -
HANNA HI762 residual chlorine Tintometer
$ 192.00 -
LEICI PNH3 -3 Ammonia Gas sensing electrode Adapted to DWS-296 Ammonia Nitrogen Analyzer BNC (Q24 type)
$ 486.00 -
LEICI 972101 Fluorine ion composite electrode
$ 263.00
High-performance wireless Bluetooth Ion Meter, suitable for Android smartphones or tablets, 5-point key calibration, the meter can be equipped with various ion selective electrodes, measurement accuracy: 1% FS.
This S30-NH4 is used to test the concentration of ammonium ions with a range of 5x10(-6)~1mol/L and an accuracy of ±0.5%FS.
Features
• High-performance Bluetooth Ion Meter, providing 5 ion concentration measurement methods.
• Optional ion concentration units, including ppm, mg/L, mol/L and mmol/L.
• 2 to 5 point calibration, including 8 concentration calibration points are optional.
• Electrode management, can store 3 electrode slopes and recall calibration data.
• Manual temperature compensation to eliminate measurement errors caused by temperature deviation.
• Automatic end point locking, keeping stable readings for easy viewing and recording.

• Timed interval readings, sending measurement data to memory or printer.
• Limit alarm, automatically warns if the measured value exceeds the set range.
• Calibration Due Reminder, reminding users to calibrate the meter regularly.
• Calibration report showing date, time, calibration point and slope.
• Password protection to prevent unauthorized calibration and setup.
• Multi-parameter measurement, can connect Bluetooth conductivity and Dissolved Oxygen Meter to the device and display the measured value.
• Reset function, automatically restores the instrument to factory default settings.
S series selection
S10: Meter, pH standard buffer, carrying case
S20: Meter, solution storage bottle, carrying case
S30: Measuring instrument, ion selective electrode (made in USA), standard solution (100 /1000ppm), ionic strength adjuster, carrying case
S40: measuring instrument, water hardness electrode (made in UK), standard solution (0.01/0.1mol/L), ionic strength adjuster, carrying case
S50: Meter, conductivity standard solution, carrying case
S60: Meter, Dissolved Oxygen Electrode Made in USA, ( ) Electrolyte, Electrode Diaphragm Cap, Carrying Case

S30 series specification parameter table
| model | parameter | Range |
| S30-NH4 | ammonium ion | 5x10 -6 ~1mol/L |
| S30-Br | bromide ion | 5x10 -6 ~1mol/L |
| S30-Ca | calcium ion | 5x10 -7 ~1mol/L |
| S30-CL | Chloride | 5x10 -6 ~1mol/L |
| S30-Cn | Cyanide | 5x10 -6 ~0.01mol/L |
| S30-F | Fluoride ion | 1x10 -6 mol/L~saturated |
| S30-NO3 | Nitrate | 7x10 -6 ~1mol/L |
| S30-Ag | silver ion | 1x10 -7 ~1mol/L |
| S30-Na | sodium ion | 1x10 -7 ~1mol/L |
| S30-Cd | Cadmium ion | 1x10 -5 ~1mol/L |
| S30-Cu | Copper ions | 1x10 -6 ~0.1mol/L |
| S30-I | iodide ion | 1x10 -8 ~0.1mol/L |
| S30-Pb | lead ion | 5x10 -8 ~1mol/L |
| S30-K | Potassium ion | 1x10 -8 ~0.1mol/L |
| S30-S | Sulfide ion | 1x10 -6 ~1mol/L |
| S30-NH3 | Ammonium ion | 1x10 -6 ~1mol/L |
| S30-WH | water hardness | 0.05~200mmol/L |
Bante S30-NH4 Bluetooth Ion MeterSpecifications
| LIST | VALUE |
|---|---|
| Ion concentration Measurement range | 0.000005~1mol/L |
| Ion concentration display resolution | 0.001, 0.01, 0.1, 1 |
| Ion concentration measurement Accuracy | ±0.5% F.S |
| Ion concentration calibrating point | 2 to 5 point |
| Ion concentration calibrating solution | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 |
| Ion Concentration Measurement Units | ppm, mg / L, mol / L, mmol / L |
| Ion concentration measurement method | Direct reading, known addition, known reduction, sample addition, sample reduction |
| Ion concentration electrode management | 1 to 3 electrodes |
| mV range | ±2000.0mV |
| mV display resolution | 0.1, 1mV, optional |
| mV measurement Accuracy | ±0.2mV |
| Temperature compensation range | 0~100 ℃/32~ 212 ° F, manual |
| Stability condition | Fast, standard, high precision |
| Measurement mode | Continuous or automatic endpoint locking |
| Timed interval reading | 10, 30, 60, 300 seconds or off |
| Calibrated reminder | 1 to 99 days or off |
| data transmission | Send to memory or printer |
| password protection | 6 digits |
| Connectivity | Bluetooth 4.0 or higher |
| Maximum transmission distance | 10 meters |
| Power Type | 1.2V lithium battery or AAA battery 2 pcs |
| Dimensions | F40 * 175mm |
| Gauge Weight | 100g |
| Measurement parameters | ammonium ion |
Bante S30-NH4 Bluetooth Ion Meter Packing list
Host X1, electrode X1, calibrating liquid X2, enhancer X1, carrying case X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


S30-NH4