BANTE S50-M S50 Wireless Bluetooth Conductivity Meter conductivity TDS salinity Conductivity Detector Ash meter
Measurement accuracy: 0.5% F.S. with conductivity, TDS, salinity, resistivity and Conductivity Detector ash. With 84 µS/cm, 1413 µS/cm, 12.88mS/cm Conductivity Detector standard solution
Bante-
LEICI DDB-305A Portable Conductivity Meter 1.0 level conductivity TDS temperature value
$ 431.00 -
BANTE A150-S Laboratory conductivity /TDS/salinity/resistivity meter
$ 545.00 -
Qiwei DDS-11A precision conductivity meter 0~2 × 100000 μS/cm
$ 130.00 -
FANGZHOU FZ-705 Conductivity Detector electrode (platinum black) > 100mS/cm
$ 99.00 -
BANTE S50-M S50 Wireless Bluetooth Conductivity Meter conductivity TDS salinity Conductivity Detector Ash meter
$ 221.00
High-performance S50 wireless bluetooth conductivity meter , suitable for Android smartphones or tablet computers, the meter has conductivity, TDS, salinity, resistivity and conductivity ash measurement modes, measurement accuracy: 0.5% FS.
Features
• High-performance Bluetooth conductivity meter with platinum conductivity electrodes.
• 1 to 3 point calibration, automatic identification of conductivity standard solution.
• Optional cell constant, temperature compensation type, temperature compensation coefficient, pure water compensation coefficient, reference temperature and TDS conversion coefficient.
• Automatic temperature compensation to ensure accurate measurement of the full scale range.
• Automatic end point locking, keeping stable readings for easy viewing and recording.
• Timed interval readings, sending measurement data to memory or printer.

• Limit alarm, automatically warns if the measured value exceeds the set range.
• Calibration Due Reminder, reminding users to calibrate the meter regularly.
• Calibration report showing date, time, calibration points and conductivity cell coefficients.
• Password protection to prevent unauthorized calibration and setup.
• Multi-parameter measurement, can connect Bluetooth pH and Dissolved Oxygen Meter to the device and display the measured value.
• Reset function, automatically restores the instrument to factory default settings.
S series selection
S10: Meter, pH standard buffer, carrying case
S20: Meter, solution storage bottle, carrying case
S30: Measuring instrument, ion selective electrode (made in USA), standard solution (100 /1000ppm), ionic strength adjuster, carrying case
S40: measuring instrument, water hardness electrode (made in UK), standard solution (0.01/0.1mol/L), ionic strength adjuster, carrying case
S50: Meter, conductivity standard solution, carrying case
S60: Meter, Dissolved Oxygen Electrode Made in USA, ( ) Electrolyte, Electrode Diaphragm Cap, Carrying Case

Bante S50-M Bluetooth conductivity /TDS/salinity/resistivity/Conductivity Detector ash meterSpecifications
| LIST | VALUE |
|---|---|
| Measuring range | 10μS/cm~20mS/cm |
| Conductivity Detector resolution | 0.001, 0.01, 0.1, 1 |
| Conductivity Detector calibrated point | 1 to 3 point |
| Conductivity Detector calibrating fluid | 84µS, 1413µS, 12.88mS, 111.8mS |
| TDS range | 0~20.00g/L |
| TDS resolution | 0.01, 0.1, 1 |
| TDS measurement Accuracy | ±1% F.S. |
| TDS conversion factor | 0.01 to 1.00 (default 0.5) |
| Salinity range (practical salinity) | 0.00~10.00psu |
| Salinity range (sea water) | 0.00~10.00ppt |
| Salinity range | 0.00~1.00% |
| Salinity display resolution | 0.01 |
| Salinity measurement Accuracy | ±1% F.S. |
| Resistivity Measurement range | 0.00 ~ 10.00MZ |
| Resistivity display resolution | 0.01, 0.1, 1 |
| Conductivity Detector ash Measurement range | 0~100% |
| Conductivity Detector ash display resolution | ±1% F.S. |
| Conductivity Detector ash measurement mode | Refined or jagged sugar |
| Temperature compensation range | 0~100℃ |
| temperature compensation coefficient | Linear (0.0~10.0%/℃), Nonlinear, USP, EP |
| Pure water compensation | contain |
| reference temperature | 20/25°C |
| Conductivity Detector cell constant | K=1 |
| Stability condition | Fast, standard, high precision |
| Measurement mode | Continuous or automatic endpoint locking |
| Timed interval reading | 10, 30, 60, 300 seconds or off |
| Calibrated expiration reminder | 1 to 99 days or off |
| data transmission | Send to memory or printer |
| password protection | 6 digits |
| Connectivity | Bluetooth 4.0 or higher |
| Maximum transmission distance | 10 meters |
| Power Type | 1.2V lithium battery or AAA battery 2 pcs |
| Dimensions | 185 * F40mm |
| Gauge Weight | 100g |
| Temperature compensation method | automatic |
Bante S50-M Bluetooth conductivity /TDS/salinity/resistivity/Conductivity Detector ash meter Packing list
S50 Conductivity Meter, Conductivity detector standard solution (84 µS/cm, 1413 µS/cm, 12.88mS/cm), AAA battery, plastic carrying case
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJG 2059-2014
- ActiveJJF 2105-2024
- ActiveJB/T 9366-2017
- ActiveSL 78-1994
- ActiveGB/T 1576-2018
- ActiveGB/T 12582-1990
- ActiveGB/T 13580.3-1992
- ActiveGB/T 6539-1997
- ActiveGB/T 18932.15-2003
- ActiveGB/T 11007-2008
- ActiveGB/T 23977-2009
- ActiveGB/T 20245.3-2013
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007
- ActiveGB/T 32697-2016
- ActiveGB/T 33328-2016
- ActiveISO 21318-2007
- ActiveISO 9944-1990
- ActiveISO 8502-9-2020


S50-M
S50-H






