BANTE S60 wireless bluetooth Dissolved Oxygen Meter dissolved oxygen concentration BOD OUR SOUR
High-performance wireless Bluetooth Dissolved Oxygen Meter, suitable for Android smartphones or tablets, the meter has dissolved oxygen concentration, BOD, OUR and SOUR Measurement mode, Measurement accuracy: 0.2mg/L.
Bante-
Bante901P-UK Portable multiparameter water quality measurement meter pH/Conductivity Meter
$ 535.00 -
HANNA HI97770 Silica/Silicon [HR] Portable Photometer
$ 540.00 -
LEICI nitrate ion electrode calibrating solution, suitable for nitrate ion composite electrode
$ 106.00 -
JINGQI WD8219 Arsenic Tester
$ 481.00 -
HANNA HI98311 conductivity EC/TDS total solid solubility Measurement Instrument
$ 267.00
S60 wireless bluetooth Dissolved Oxygen Meter is suitable for Android smartphones or tablet computers. The meter has dissolved oxygen concentration, BOD, OUR and SOUR measurement modes, and the measurement accuracy is 0.2mg/L.
Features
• High performance wireless bluetooth Dissolved Oxygen Meter with polarographic electrodes.
• 1 or 2 point calibration, using air saturated water or zero oxygen liquid.
• Salinity and barometric pressure compensation to eliminate measurement errors.
• Optional test time, start/end DO to calculate oxygen consumption rate (OUR) and specific oxygen consumption rate (SOUR).
• Data management function provides detailed BOD information, including date/time, temperature, initial/final DO.

• Automatic temperature compensation to ensure accurate measurement of the full scale range.
• Automatic end point locking, keeping stable readings for easy viewing and recording.
• Limit alarm, automatically warns if the measured value exceeds the set range.
• Calibration Due Reminder, reminding users to calibrate the meter regularly.
• Password protection to prevent unauthorized calibration and setup.
• Multi-parameter measurement, can connect Bluetooth pH and conductivity meter to the device and display the measured value.
• Reset function, automatically restores the instrument to factory default settings.
S series selection
S10: Meter, pH standard buffer, carrying case
S20: Meter, solution storage bottle, carrying case
S30: Measuring instrument, ion selective electrode (made in USA), standard solution (100 /1000ppm), ionic strength adjuster, carrying case
S40: measuring instrument, water hardness electrode (made in UK), standard solution (0.01/0.1mol/L), ionic strength adjuster, carrying case
S50: Meter, conductivity standard solution, carrying case
S60: Meter, Dissolved Oxygen Electrode Made in USA, ( ) Electrolyte, Electrode Diaphragm Cap, Carrying Case

Bante S60 Bluetooth dissolved oxygen/BOD/OUR/SOUR meterSpecifications
| LIST | VALUE |
|---|---|
| DO range | 0.00~20.00mg/L |
| DO resolution | 0.01, 0.1mg/L, optional |
| DO measurement Accuracy | ±0.2mg/L |
| DO% Measurement range | 0.0~200.0% |
| DO% resolution | 0.1% |
| DO% measurement Accuracy | ±2.0% |
| Calibrated point | 1 or 2 point |
| Temperature compensation range | 0~50 ℃/32~ 122 ° F, automatic |
| Pressure compensation range | 60.0~113.3kPa/450~850mmHg, manual |
| Salinity compensation range | 0.0~50.0G/L, manual |
| Measurement function | Dissolved Oxygen, BOD, Oxygen Consumption Rate (OUR), Specific Oxygen Consumption Rate (SOUR) |
| Stability condition | Fast, standard, high precision |
| Measurement mode | Continuous or automatic endpoint locking |
| Timed interval reading | 10, 30, 60, 300 seconds or off |
| Calibrated reminder | 1 to 99 days or off |
| data transmission | Send to memory or printer |
| password protection | 6 digits |
| Connectivity | Bluetooth 4.0 or higher |
| Maximum transmission distance | 10 meters |
| Power | 1.2V lithium battery or AAA battery 2 pcs |
| Dimensions | 175 * 40 (diameter) mm |
| Instrument Weight | 100g |
Bante S60 Bluetooth dissolved oxygen/BOD/OUR/SOUR meter Packing list
S60 wireless Bluetooth dissolved oxygen meter, DO100 dissolved Oxygen electrode (made in the United States), dissolved Oxygen electrode filling solution, dissolved Oxygen electrode film cap, AAA battery, plastic carrying case
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 1714-2018
- ActiveJJF 1565-2016
- ActiveJJF 1441-2013
- ActiveJJG 2104-2024
- Active 096-2007
- ActiveSC/T 7006-2001
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveGB/T 18920-2020
- ActiveGB/T 1576-2018
- ActiveHJ 2515-2012


S60


![HANNA HI97770 Silica/Silicon [HR] Portable Photometer](http://img.nbchao.com/imgs/200/2024/03/28/1725050916848944.jpg)