3NH YT4200-P7 split aluminum-based Coating Thickness Gauge
3NH YT4200-P7 split aluminum-based Coating Thickness Gauge adopts split probe, matrix NFe, resolution 0.1/1 μm, YT4200-P7 split aluminum-based Coating Thickness Gauge can test various non-conductive Coating thickness coated on nonmagnetic metal substrates.
3NH-
LEEB222 (F1) magnetic Induction Coating Thickness Gauge magnetic metal substrate
Login -
List MEGA-CHEK Basic platings Thickness Gauge
$ 1392.00 -
IWAVE WH-82 Coating Thickness Gauge magnetic and eddy current
$ 173.00 -
DONGRU DR5000S Coating Thickness Gauge 0~5000μm
$ 257.00 -
AMITTARI AC-110MC Integrated Coating Thickness Gauge Dual function Film Thickness Gauge 0~500μm
$ 265.00
Introduction
YT4200 is a domestic (CN) coating Thickness Gauge manufactured by 3nh company, which can quickly and accurately non-destructively detect various non-conductive coating thicknesses coated on non-magnetic metal substrates. The instrument fully conforms to the eddy current test principle stipulated in ISO 2360, GB/T 4957, ASTM B1400 and other standards, and is the basic equipment of the coating surface treatment industry.
Application industry
NFe-based probes inspect all insulating coating thicknesses, such as paint, powder, porcelain, etc., applied to non-magnetic metal substrates (e.g., aluminum, copper, brass, stainless steel, etc.).
Features
a. Quickly and accurately test the thickness of the insulating coating on a variety of non-magnetic metal substrates (eddy current method);
b. The probe and the host are separated, and the adaptability is stronger;
c. One-click test, convenient and fast;
d. The instrument can be accurately calibrated by using two methods: single-point calibration and multi-point calibration;
e. Low power consumption is more power saving, low power alarm;
f. With backlit display, buzzer prompt;
g. High wear-resistant probe, not less than 800,000 measurements;
h. Multiple measurement modes: single point measurement, continuous measurement;
3NH YT4200-P7 Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Standards | ASTM B499,ASTM D1400;ISO 2178,ISO 2360,ISO 2808;GB/T 4956/4957,JB/T 8393 |
| matrix material | NFe |
| Probe position | Split |
| Resolution | 0.1μm|1μm |
| Measurement range | 0~1250μm |
| margin of error | Zero correction : +/- ( 3% H + 1) μm; two-point correction : +/- ( 1~ 3% H + 1.5) μm; Note: H is the sample thickness |
| Small measurement size | 10×10mm |
| Minimum substrate thickness | Nonmagnetic: 0.05mm |
| Minimum radius of curvature | Convex radius 5mm; Concave radius 10mm |
| Unit display | μm |
| Power Supply | 2 AA alkaline batteries or NiMH rechargeable batteries; |
| Dimensions | 102*66*24mm |
| Weight | 99G (including battery) |
| Operating temperature | 0~40 ℃ (10~90% RH without condensation) |
| Storage temperature | -10~50℃ |
| Standard Accessories | Base 1 piece (aluminum base), wrist strap, calibrated test piece |
| Optional accessories | Calibrated specimens (12 μm, 25 μm) |
3NH YT4200-P7 Coating Thickness Gauge Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Principle and Application Scope of Copper Plate Magnetic Induction Thickness Gauge
- Principle and Application Analysis of Silver Plating Thickness Gauge


YT4200-P7