Sanenchi/3nh YH1210 Horizontal Haze Meter φ 20mm
Supports ASTM D1003 non-compensation method and ISO 13468 compensation method, uses PD array Detector, conforms to CIE V (lambda) 2 visual Response, large size touch screen, USB data output. Dynamic measurement system, open sample compartment supports vertical and horizontal testing, suitable for a variety of samples
3NHIntroduction
YH1210 horizontal haze meter can easily implement ASTM D1003 non-compensation method, ISO 13468 compensation method, total light transmittance, haze test, and the open sample chamber can be tested vertically and horizontally, adapting to more samples to be tested. YH1210 haze meter adopts PD array Detector, which meets CIE V(λ)2-degree visual response, and compensation method measurement can realize high-precision and repeatable light transmittance and haze data measurement.
Advantages
1. Double standard ISO & ASTM
It can meet the test standard requirements of different users and meet the standards: ASTM D1003/1044, ISO 13468, ISO 14782, GB/T 2410, JJF 1303-2011, CIE 15.2, GB/T 3978, ASTM E308, JIS K7105, JIS K7361, JIS K 7136
2. Easy to operate, faster and more accurate measurement
The YH1210 haze meter is equipped with a large-size touch screen, which is easy and convenient to operate. It adopts a PD array Detector and meets the CIE V(λ) 2-degree visual response to achieve high-precision and repeatable transmittance and haze measurements. USB data output device, can be docked with laboratory system.
3. Dynamic measurement
Independent light source Detector and temperature sensor to monitor light source and environmental changes at all times to ensure reliable test data
4. With a compensation port to make the measurement data more accurate
Meet ASTM D1003 non-compensation method, ISO 13468 compensation method, total light transmittance, haze test, provide more accurate test results
5. The measurement is convenient and the sample is suitable for a wide range of
Open measurement area, can be tested vertically and horizontally, adapting to more samples to be tested
6. Quality management software
Provide powerful haze and light transmittance measurement and analysis software, which is suitable for quality monitoring and tabular management of haze and light transmittance data in various industries. Dataize the user's management on the PC side, compare the differences in haze and light transmittance, and generate a test report form to facilitate customer customization and management.
Applications
YH1210 haze meter is widely used in transmittance and haze detection in glass processing, plastic processing, film, display screen processing, packaging and other industries.
3NH YH1210(Φ20mm) Horizontal Haze MeterSpecifications
| LIST | VALUE |
|---|---|
| Lighting method | Transmission: 0/D (parallel light illumination, diffuse reflection reception) |
| Standards | ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,GB/T 3978,ASTM E308,JIS K7105,JIS K7361,JIS K 7136 |
| Integrating sphere size | F154mm |
| lighting source | 400~700Nm combined LED light source |
| sensor | PD Array Detector with CIE V (λ) 2 Degree Visual Response |
| Transmittance range | 0~100% |
| Measurement aperture | F20mm |
| Sample size | Film thickness less than 105mm |
| Other chromaticity indicators | Haze (ASTM D1003/1044, ISO 13468), light transmitance T (ISO), light transmitance T (ASTM) |
| Observer angle | 2° |
| Observation light source | D65,A,C |
| show | Pass/Fail Results |
| Measurement time | About 1.5s |
| haze resolution | 0.01 unit |
| Haze, sexual repeability | Φ20mm diameter, less than 0.05 (after the instrument is preheated and corrected, the standard haze sheet with a haze of about 40 is tested 30 times at an interval of 5s) |
| Inter-station difference | Φ20mm diameter, less than 0.4 (after the instrument is preheated and corrected, the standard deviation between the standard haze sheet and the reference value is tested at intervals of 5s) |
| size | Length X width X height = 487X260X298mm |
| Weight | Approx. 8.0kg |
| Power Supply | DC 24V, 3A power adapter Power |
| Lighting source life | 5 years more than 3 million measurements |
| Display | TFT true color 7inch, capacitive touch screen |
| interface | USB, print serial port |
| Store data | 1000 master standards, 20,000 samples |
| language | Simplified Chinese, Traditional Chinese, English |
| Operating temperature range | 0~40℃(32~104°F) |
| Storage temperature range | -20~50℃(-4~122°F) |
3NH YH1210(Φ20mm) Horizontal Haze Meter Packing list
Host X1, power adapter X1, quality management software (official website download) X1, data cable X1, calibration box X1, measurement diameter X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 44572-2024
- IncomingGB/T 19787-2025
- ActiveJJF 1303-2011
- ActiveJIS
- ActiveGB/T 27740-2011
- ActiveGB/T 10003-2008
- ActiveGB/T 4456-2008
- ActiveASTM D1003-2021
- ActiveHG/T 5065-2016
- ActiveHG/T 5297-2018
- ActiveHG/T 5076-2016
- ActiveHG/T 5299-2018
- ActiveGB/T 2410-2008
- ActiveGB/T 2005-19787


YH1210(Φ20mm)
YH1210(Φ4mm)
YH1210(Φ8mm)
YH1210(Φ15mm)
YH1610(Φ20mm)