JINGTIAN SNB-2 digital display Rotational Viscometer laboratory viscometer with L0 rotor
Fine digital display Rotational Viscometer SNB-2 adopts LCD, with L0 rotor, the measurement Viscosity range is 0.6~ 6000000mPa·s, the measurement accuracy of SNB-2 Rotational Viscometer is ± 1%, and the speed range is 0.1~ 99.9rpm.
JingTian-
NIRUN NTV-CAP2 cone-plate viscometer Rotation speed 900rpm/750rpm/400rpm
$ 7341.00 -
NIRUN CPE-51 cone-plate viscometer rotor, shear rate 3.84N
$ 658.00 -
HuiNuo NDJ-8S Digital Rotational Viscometer Rotor Viscometer 2 million CP
$ 405.00 -
NIRUN RDV-2 + Pro Digital Viscometer Measurement range 20-40 million cP
$ 3526.00 -
Shangtian Jingyi NDJ-5S Digital Viscometer NDJ Digital Rotational Viscometer 1X10 mPa · s
$ 683.00
Introduction
The LCD of Shanghai JINGTIAN SNB-2 digital display rotary viscometer can display viscosity, shear rate, shear stress, rotational speed, temperature, percentile torque, rotor number and the maximum measurable value of the selected rotor at the current rotational speed. Viscosity value etc. It is a digital display rotary viscometer with a measuring range of 12 to 6,000,000 mPa·s.

Introduction
Accurately measure ultra-low viscosity samples
Sample volume only needs 25~30mL
It can measure lower viscosity and be used with different types of viscometers

JingTian SNB-2 + L0 Digital Rotational ViscometerSpecifications
| LIST | VALUE |
|---|---|
| Measuring range | 0.6~6000000mPa·s |
| Rotor Specifications | L0#、L1#、L2#、L3#、L4# |
| Reproducibility | ±0.5%F.S |
| Measurement Accuracy | ±1%F.S |
| Power | Dedicated power adapter (input 100~240V 50~60Hz) |
| Rotor speed | 0.1~99.9rpm |
| Display information | Viscosity, rotational speed, percentile torque, rotor number and the maximum measurable Viscosity value of the selected rotor at the current rotational speed, etc |
| Speed control method | CVT |
JingTian SNB-2 + L0 Digital Rotational Viscometer Packing list
Main unit X1, protection frame X1, rotor X1 (sleeve), L0 rotor, base and horizontal adjustment bolt X1, lifting frame and lifting mechanism X1, special power adapter X1, wrench X1, RTD temperature probe X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveSJ/T 10454-2020
- ActiveHG/T 4443-2012
- ActiveHG/T 3323-2008
- ActiveHG/T 5187-2017
- ActiveGB/T 13217.4-2020
- ActiveHG/T 3948-2007
- ActiveASTM D3794-2022
- ActiveISO 12634-2017
- ActiveJJG 1002-2005
- ActiveGB/T 22427.7-2008
- ActiveGB/T 18856.4-2008
- ActiveSN/T 2903-2011
- ActiveGB/T 17473.5-2008
- ReplacedHG/T 3323-1982
- ActiveSY/T 0522-2008
- ActiveHG/T 3660-1999
- ActiveGB/T 21882-2008
- AbolishGB/T 11175-2002
- ActiveSY/T 5377-2007
- ActiveSY/T 0520-2008


SNB-2 + L0