JINGTIAN HBDV-2 Digital Rotational Viscometer with L0 rotor
The HBDV-2 Digital Rotational Viscometer has a reproducibility of ± 0.5% and a measurement accuracy of ± 1%. The measuring range of the HBDV-2 Viscosity meter is 25~ 320000000mPa·s, and it is equipped with seven kinds of rotors.
JingTian-
HUINUO SNB-1 Digital Display Rotational Viscometer Viscosity Testing Instrument with Ultra Low Viscosity Adapter
$ 988.00 -
TRUIT TR 1101/5 Digital Rotational Viscometer 10-100000mPa.s
$ 1034.00 -
NIRUN DV-79 Digital Viscometer Set, Viscosity 1-1 million cP
$ 1372.00 -
TQC DV2010 Viscometer 0-22P For DV2700 Rotothinner Rotational Viscometer
$ 651.00 -
FANGRUI SNB-2 Digital Rotational Viscometer Viscosity range 1~ 6 million cp
$ 556.00
Introduction
The LCD of Shanghai JINGTIAN HBDV-2 digital display rotary viscometer can display viscosity, shear rate, shear stress, rotational speed, temperature, percentile torque, rotor number and the maximum measurable value of the selected rotor at the current rotational speed. Viscosity value etc. It is a digital display rotary viscometer with a measuring range of 320 to 320,000,000 mPa·s.

Introduction
Accurately measure ultra-low viscosity samples
Sample volume only needs 25~30mL
It can measure lower viscosity and be used with different types of viscometers

JingTian HBDV-2+L0 Digital Rotational ViscometerSpecifications
| LIST | VALUE |
|---|---|
| Measuring range | 25~320000000mPa·s |
| Rotor Specifications | 1 piece each of rotors L0, R2, R3, R4, R5, R6 and R7 |
| Reproducibility | ±0.5%F.S |
| Measurement Accuracy | ±1%F.S |
| Power | Dedicated power adapter (input 100~240V 50~60Hz) |
| Rotor speed | 0.1~200rpm |
| Display information | Viscosity, shear rate, shear stress, rotational speed, temperature, percentile torque, rotor number and the maximum Viscosity value that can be measured at the current rotational speed of the selected rotor, etc |
| Speed control method | CVT |
JingTian HBDV-2+L0 Digital Rotational Viscometer Packing list
Host X1, protection frame X1, rotor X1 (sleeve), L0 rotor, base and horizontal adjustment bolt X1, lifting frame and lifting mechanism X1, special power adapter X1, wrench X1, RTD temperature probe X1, RS232 standard output interface X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveSJ/T 10454-2020
- ActiveHG/T 4443-2012
- ActiveHG/T 3323-2008
- ActiveISO 19613-2018
- ActiveGB/T 21059-2007
- ActiveHG/T 5187-2017
- ActiveGB/T 13217.4-2020
- ActiveHG/T 3948-2007
- ActiveASTM D3794-2022
- ActiveISO 12634-2017
- ActiveJJG 1002-2005
- ActiveGB/T 22427.7-2008
- ActiveGB/T 18856.4-2008
- ActiveSN/T 2903-2011
- ActiveGB/T 17473.5-2008
- ReplacedHG/T 3323-1982
- ActiveSY/T 0522-2008
- ActiveHG/T 3660-1999
- ActiveGB/T 21882-2008
- AbolishGB/T 11175-2002