Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Rotational Viscometer> JingTian> JingTian HBDV-2+SSA Digital Rotational Viscometer

      JINGTIAN HBDV-2 digital Rotational Viscometer with small sample adapter

      JINGTIAN HBDV-2 digital display Rotational Viscometer with a small number of sample adapters, easy to disassemble, easy to clean, HBDV-2 digital display Rotational Viscometer can display viscosity, shear rate, shear stress, Rotation speed, temperature, percentile torque, rotor number and the maximum viscosity value of the selected rotor at the current Rotation speed.

      Brand
      SKU: NB035880
      China JingTian
      VS
      Genuinegoods
      • JingTian HBDV-2+SSA Digital Rotational ViscometerOverview

      • Specifications
      • Comments
      • FAQs
      HBDV-2+SSA
      Digital Rotational Viscometer

      Introduction

      The LCD of Shanghai JINGTIAN HBDV-2 digital display rotary viscometer can display viscosity, shear rate, shear stress, rotational speed, temperature, percentile torque, rotor number and the maximum measurable value of the selected rotor at the current rotational speed. Viscosity value etc. It is a digital display rotary viscometer with a measuring range of 320 to 320,000,000 mPa·s.

      JINGTIAN HBDV-2+SSA Digital Display Rotary Viscometer Details Figure 1

      Introduction to Small Sample Adapters

      • With 21, 27, 28, 29 rotors each one

      • Small sample volume, only 10-20mL, especially suitable for expensive sample testing

      • A constant temperature bath connected with external circulation function can control the temperature of the tested sample

      • Easy to disassemble and clean

      JINGTIAN HBDV-2+SSA Digital Display Rotary Viscometer Details Figure 2

      Viscometer structure diagram

      JINGTIAN HBDV-2+SSA Digital Display Rotary Viscometer Details Figure 3

      VS

      JingTian HBDV-2+SSA Digital Rotational ViscometerSpecifications

      LIST VALUE
      Measurement range 320~320000000mPa·s
      Rotor specification R2、R3、R4、R5、R6、R7、21#、27#、28#、29#
      Reproducibility ±0.5%F.S
      Measurement Accuracy ±1%F.S
      Power Dedicated power adapter (input 100~240V 50~60Hz)
      Rotor speed 0.1~200rpm
      Display information Viscosity, shear rate, shear stress, Rotation speed, temperature, percentile torque, rotor number and the maximum viscosity value of the selected rotor at the current Rotation speed, etc
      Capacity 10~20mL
      Rotation speed Control mode Continuously variable speed

      JingTian HBDV-2+SSA Digital Rotational Viscometer Packing list

      Host X1, protection frame X1, rotor X1 (sleeve), base and horizontal adjustment bolt X1, lifting frame and lifting mechanism X1, special power adapter X1, wrench X1, a small number of sample adapters X1 (sleeve)

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Hello, I would like to ask the snb-3 digital Viscometer what is the range of shear rate measurement if you choose data collection and drawing software. I mainly want to test the viscosity of coal water slurry.
      [A]
      For example, in the standard I just sent, according to items 2.3 and 5 of this standard, HVDV-2 plus a small amount of sample adapter is recommended, and the effective viscosity range at 100 1/S is 371.8~ 3345.8mPa.s.
      [Q]
      How should the Viscometer rotor be maintained?
      [A]
      1. The instrument should be used in a normal temperature environment. 2. When loading and unloading the rotor, be careful not to use too much force. 3. The connection section and thread of the screw and rotor should be kept clean. 4. Clean the rotor in time after each use, and do not clean the rotor on the instrument. 5. After installing the rotor, do not "swirl/spin" without liquid to avoid damage to the shaft tip. 6. Do not disassemble and adjust the instrument parts at will, and do not add lubricating oil by yourself. 7. Clean the instrument and button panel with a dry and soft cloth, do not clean with solvent or detergent
      [Q]
      Colloidal, viscosity range 10,000 or so, this one is OK?
      [A]
      What kind of glue? Glues are all non-newtonian fluids, which are related to Measurement conditions. You need to ask a little more carefully.
      [Q]
      The same rotor test liquid viscosity, but set different Rotation speed measurement of the same liquid, the measured viscosity is different What is the reason?
      [A]
      This is the reason for non-Newtonian liquids. Rotation speed, stator and rotor, temperature, and some special samples also need to determine the measurement time. This requires users to refer to industry measurement standards
      [Q]
      Is this Viscometer compliant with the JJG1002 standard?
      [A]
      This Viscometer is suitable for JJG1002. Please consult customer service for detailed application definition.
      JingTian
      JINGTIAN HBDV-2 digital Rotational Viscometer with small sample adapter
      Service
      Focus on online sales of Lab Testing Instruments