      TENLIN DC-4506 Vertical Low Temperature Circulating Bath - 45 ℃/ +/- 0.03 ℃ 7.5L

      -45~ 100 ℃, Temperature resolution 0.01 ℃, Temperature Fluctuation +/- 0.03 ℃, 2.2kw, Tank volume 7.5L, Tank opening dimensions 180 * 160mm, Tank depth 150mm, Pump Flow rate 6L/min. Selling point

      Brand
      SKU: NB035935
      China TenLin
      Model
      VS
      Genuinegoods
      • TenLin DC-4506 Vertical Low Temperature Circulating BathOverview

      • Specifications
      • Comments
      • FAQs
      DC-4506
      Vertical Low Temperature Circulating Bath
      • TENLIN DC-4506 Vertical Low Temperature Circulating Bath - 45 ℃/ +/- 0.03 ℃ 7.5L
      • TENLIN DC-4506 Vertical Low Temperature Circulating Bath - 45 ℃/ +/- 0.03 ℃ 7.5L Figure 1
      • TENLIN DC-4506 Vertical Low Temperature Circulating Bath - 45 ℃/ +/- 0.03 ℃ 7.5L Figure 2
      -45~ 100 ℃, Temperature resolution 0.01 ℃, Temperature Fluctuation +/- 0.03 ℃, 2.2kw, Tank volume 7.5L, Tank opening dimensions 180 * 160mm, Tank depth 150mm, Pump Flow rate 6L/min. Selling point

      Features

      ● New self-developed temperature control technology, equipped with high-standard PT100 and all imported electronic components.

      ● The software system can correct the error between the displayed temperature and the actual temperature, so that the displayed temperature value is accurate.

      ● Equipped with large-screen liquid crystal display as standard, multiple data can be seen at a glance, and the resolution of temperature display is up to 0.01℃.

      ● With over-temperature protection, over-temperature beep alarm, over-temperature alarm temperature can be set, and the load can be automatically cut off when over-temperature.

      ● With timing function, the total working time of the equipment can be set, and the load will be cut off automatically when the time comes.

      ● Hidden cooling coil design ensures a larger space in the tank.

      ● Intelligent software has strong temperature stability, PID can automatically adjust the appropriate parameters according to different media, and special users can manually readjust the parameters.

      ● Use the software to digitally lock the setting values ​​of the control system to avoid misoperation by irrelevant personnel and ensure that the data during the experiment is correct.

      ● Effective full-enclosed compressor refrigeration, fast cooling speed, with multiple protections such as overheating and overcurrent.

      ● The internal and external circulation function is equipped as standard, and the outer diameter of the external circulation inlet and outlet is a round pipe with an outer diameter of 10mm, which meets the different needs of users in multiple scenarios.

      ● Support non-standard customization.

      Optional

      Liquid level protection system --- When the liquid level exceeds the limit, the load will be stopped forcibly to protect the user's experiment.

      RS485 communication interface--connect to a host computer such as a computer, and the host computer software controls the device and checks the data.

      Multi-point correction function-can correct multiple temperature points at the same time, avoiding the temperature difference caused by the linear error of the sensor.

      External PT100 - can realize the precise temperature control of the external circulation.

      Bracket--Satisfied that different containers are placed in the tank to avoid being submerged in constant temperature liquid.

      external structure

      TENLIN DC-4030 Vertical Low Temperature Constant Temperature Bath Details Figure 1

      Figure 1: Outline structure of DC constant temperature bath

      TENLIN DC-4030 Vertical Low Temperature Constant Temperature Bath Details Figure 2

      Figure 2: DC thermostatic bath control panel

      Model parameters

      modeltemperature rangepowertank volume
      DC-0506-5~1000.87.5
      DC-1006-10~1000.9
      DC-2006-20~1001
      DC-3006-30~1001.5
      DC-4006-40~1002.1
      DC-4506-45~1002.2
      DC-0510-5~1001.310
      DC-1010-10~1001.5
      DC-2010-20~1001.8
      DC-3010-30~1002
      DC-4010-40~1002.1
      DC-0515-5~1002.115
      DC-1015-10~1002.2
      DC-2015-20~1002.3
      DC-3015-30~1002.4
      DC-4015-40~1002.5
      DC-0520-5~1002.320
      DC-1020-10~1002.4
      DC-2020-20~1002.5
      DC-3020-30~1002.6
      DC-4020-40~1002.7
      DC-0530-5~1002.530
      DC-1030-10~1002.6
      DC-2030-20~1002.7
      DC-3030-30~1002.7
      DC-4030-40~1003
      same parameters
      resolution0.01°C
      Volatility±0.03℃
      Unit: ℃/Kw/L


      VS

      TenLin DC-4506 Vertical Low Temperature Circulating BathSpecifications

      LIST VALUE
      Temperature range -45~100℃
      temperature resolution 0.01℃
      Temperature fluctuation ±0.03℃
      Dimensions 400*450*940mm
      power 2.2kw
      Tank Volume 7.5L
      Tank opening Dimensions 180*160mm
      Tank Depth 150mm
      Pump flow 6L/min

      TenLin DC-4506 Vertical Low Temperature Circulating Bath Packing list

      host X1, cover X1, manual X1, certificate X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Is this domestic circulation or external circulation?
      [A]
      Flow rate of external circulation 6 liters per minute?
      [Q]
      Has it been used for -40 degrees Celsius stability?
      [A]
      stable
      [Q]
      Has it been used for -40 degrees Celsius stability?
      [A]
      Sure
      [Q]
      Is this domestic circulation or external circulation?
      [A]
      Both internal and external circulation. Flow rate of 6 liters per minute
      [Q]
      How much liquid is appropriate in the working tank? Is there no requirement?
      [A]
      Add a liquid medium to the tank, and the liquid level of the liquid medium should not be lower than 20mm of the working table (fill up as much as possible).
      TenLin