Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Thermostat> TenLin> TenLin DC-6020 Thermostatic bath

      TENLIN DC-6020 Vertical ultra-low temperature Thermostatic bath - 60 ℃/ +/- 0.05 ℃ 20L

      20L, domestic circulation, temperature control -60-100 ℃, resolution 0.01 ℃, fluctuation +/- 0.05 ℃, Power 3.7kw

      Brand
      SKU: NB035965
      China TenLin
      Model
      VS
      Genuinegoods
      • TenLin DC-6020 Thermostatic bathOverview

      • Specifications
      • Comments
      • FAQs
      DC-6020
      Thermostatic bath
      • TENLIN DC-6020 Vertical ultra-low temperature Thermostatic bath - 60 ℃/ +/- 0.05 ℃ 20L
      • TENLIN DC-6020 Vertical ultra-low temperature Thermostatic bath - 60 ℃/ +/- 0.05 ℃ 20L Figure 1
      • TENLIN DC-6020 Vertical ultra-low temperature Thermostatic bath - 60 ℃/ +/- 0.05 ℃ 20L Figure 2
      20L, domestic circulation, temperature control -60-100 ℃, resolution 0.01 ℃, fluctuation +/- 0.05 ℃, Power 3.7kw

      Features

      ● New self-developed temperature control technology, equipped with high-standard PT100 and all imported electronic components.

      ● The software system can correct the error between the displayed temperature and the actual temperature, so that the displayed temperature value is accurate.

      ● Equipped with large-screen liquid crystal display as standard, multiple data can be seen at a glance, and the resolution of temperature display is up to 0.01℃.

      ● With over-temperature protection, over-temperature beep alarm, over-temperature alarm temperature can be set, and the load can be automatically cut off when over-temperature.

      ● With timing function, the total working time of the equipment can be set, and the load will be cut off automatically when the time comes.

      ● Hidden cooling coil design ensures a larger space in the tank.

      ● Intelligent software has strong temperature stability, PID can automatically adjust the appropriate parameters according to different media, and special users can manually readjust the parameters.

      ● Use the software to digitally lock the setting values ​​of the control system to avoid misoperation by irrelevant personnel and ensure that the data during the experiment is correct.

      ● Effective full-enclosed compressor refrigeration, fast cooling speed, with multiple protections such as overheating and overcurrent.

      ● The internal and external circulation function is equipped as standard, and the outer diameter of the external circulation inlet and outlet is a round pipe with an outer diameter of 10mm, which meets the different needs of users in multiple scenarios.

      ● Support non-standard customization.

      Optional

      Liquid level protection system --- When the liquid level exceeds the limit, the load will be stopped forcibly to protect the user's experiment.

      RS485 communication interface--connect to a host computer such as a computer, and the host computer software controls the device and checks the data.

      Multi-point correction function-can correct multiple temperature points at the same time, avoiding the temperature difference caused by the linear error of the sensor.

      External PT100 - can realize the precise temperature control of the external circulation.

      Bracket--Satisfied that different containers are placed in the tank to avoid being submerged in constant temperature liquid.

      external structure

      Figure 1: Outline structure of DC constant temperature bath

      Figure 1: Outline structure of DC constant temperature bath

      Figure 2: DC thermostatic bath control panel

      Figure 2: DC thermostatic bath control panel

      Model parameters

      modeltemperature rangepowertank volume
      DC6006-60-1003.27.5
      DC7006-70-1003.37.5
      DC8006-80-1003.57.5
      DC6010-60-1003.410
      DC7010-70-1003.510
      DC8010-80-1003.610
      DC6015-60-1003.515
      DC7015-70-1003.615
      DC8015-80-1003.715
      DC6020-60-1003.720
      DC7020-70-1003.820
      DC8020-80-1003.920
      DC6030-60-100430
      DC7030-70-1004.230
      DC8030-80-1004.530

      resolution0.01°C
      Volatility±0.05℃
      pump flowInner loop
      Unit ℃/Kw/L


      VS

      TenLin DC-6020 Thermostatic bathSpecifications

      LIST VALUE
      Temperature range -60~100℃
      temperature resolution 0.01℃
      Temperature fluctuation ±0.05℃
      Dimensions 660*660*1350mm
      power 3.7kw
      Tank Volume 20L
      Tank opening Dimensions 250*160mm
      groove depth 300mm
      Circular mode Domestic circulation

      TenLin DC-6020 Thermostatic bath Packing list

      host X1, cover X1, manual X1, certificate X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Does this vertical ultra-low temperature Thermostatic bath meet the GB/T26808 standard?
      [A]
      This vertical ultra-low temperature Thermostatic bath is suitable for GB/T26808. Please consult customer service for detailed application definition
      [Q]
      What is the ultimate low temperature of this DC-6020 Vertical Ultra Low Temperature Thermostatic bath?
      [A]
      Minimum temperature -60 ℃
      TenLin