      Home> Thermostat> TenLin> TenLin GDH-0520 High Accuracy Low Temperature Circulating Bath

      TENLIN GDH-0520 High Accuracy Low Temperature Circulating Bath - 5 ℃/ +/- 0.02 ℃ 20L

      Temperature range -5~ 100 ℃, Temperature resolution 0.001 ℃, Temperature Fluctuation +/- 0.005~ 0.02 ℃, Dimension 400 * 450 * 1040mm, Power 2.3kw, Tank volume 20L, Tank opening dimensions 250 * 160mm, Groove depth 300mm, circulation domestic circulation.

      Brand
      SKU: NB036011
      China TenLin
      VS
      Genuinegoods
      • TenLin GDH-0520 High Accuracy Low Temperature Circulating BathOverview

      • Specifications
      • Comments
      • FAQs
      GDH-0520
      High Accuracy Low Temperature Circulating Bath
      • TENLIN GDH-0520 High Accuracy Low Temperature Circulating Bath - 5 ℃/ +/- 0.02 ℃ 20L
      • TENLIN GDH-0520 High Accuracy Low Temperature Circulating Bath - 5 ℃/ +/- 0.02 ℃ 20L Figure 1
      • TENLIN GDH-0520 High Accuracy Low Temperature Circulating Bath - 5 ℃/ +/- 0.02 ℃ 20L Figure 2
      Temperature range -5~ 100 ℃, Temperature resolution 0.001 ℃, Temperature Fluctuation +/- 0.005~ 0.02 ℃, Dimension 400 * 450 * 1040mm, Power 2.3kw, Tank volume 20L, Tank opening dimensions 250 * 160mm, Groove depth 300mm, circulation domestic circulation.

      Features

      1. Refrigeration system: It adopts low-noise air-cooled hermetic compressor unit, which has the advantages of fast refrigeration speed and strong temperature stability.

      2. Control system: new special software research and development of self-made temperature control technology, equipped with high-standard Pt100 and all imported electronic components.

      3. Circulation system: It is composed of internal and external circulation. During the external circulation, the constant temperature liquid in the tank can be introduced outside, and a second constant temperature field can be established. It can also be used as a cold source to guide the refrigerated liquid in the tank to the external experimental container to cool down. When circulating, the temperature of the liquid in the tank can be very uniform and stable.

      4. Protection system: Refrigeration has overheating and overcurrent protection. The control system has functions such as over-temperature chirp alarm, upper and lower limits of temperature can be set for over-temperature alarm temperature, and the load can be automatically cut off when over-temperature.

      5. High-end large LCD control instrument, easy to operate, strong temperature stability, PID can be automatically searched or manually adjusted.

      6. The accurate temperature correction function can reach 0.01°C, and the temperature fluctuation can reach up to ±0.005-0.01°C (depending on the model).

      external structure

      TENLIN GDH-4030 High Precision Low Temperature Constant Temperature Bath Details Figure 1

      Figure 1: Outline structure of constant temperature bath

      TENLIN GDH-4030 High Precision Low Temperature Constant Temperature Bath Details Figure 2

      Figure 2: Bath control panel

      Model parameters

      modeltemperature range ℃Power KwvolumeSlot opening mmGroove depth mm
      GDH-0506-5~1000.86L180*160150
      GDH-1006-10~1000.9
      GDH-2006-20~1001
      GDH-3006-30~1001.5
      GDH-4006-40~1002.1
      GDH-0510-5~1001.310L200
      GDH-1010-10~1001.5
      GDH-2010-20~1001.8
      GDH-3010-30~1002
      GDH-4010-40~1002.1
      GDH-0515-5~1002.115L250*160200
      GDH-1015-10~1002.2
      GDH-2015-20~1002.3
      GDH-3015-30~1002.4
      GDH-4015-40~1002.5
      GDH-0520-5~1002.320L300
      GDH-1020-10~1002.4
      GDH-2020-20~1002.5
      GDH-3020-30~1002.6
      GDH-4020-40~1002.7
      GDH-0530-5~1002.530L330*280230
      GDH-1030-10~1002.6
      GDH-2030-20~1002.7
      GDH-3030-30~1002.7
      GDH-4030-40~1003
      Other parameters
      resolution0.001°C
      Volatility±0.005-0.02℃
      cycle modeInner loop


      VS

      TenLin GDH-0520 High Accuracy Low Temperature Circulating BathSpecifications

      LIST VALUE
      Temperature range -5~100℃
      temperature resolution 0.001℃
      Temperature fluctuation ±0.005~0.02℃
      Dimensions 400*450*1040mm
      power 2.3kw
      Tank Volume 20L
      Tank opening Dimensions 250*160mm
      groove depth 300mm
      Circular mode Domestic circulation

      TenLin GDH-0520 High Accuracy Low Temperature Circulating Bath Packing list

      host X1, cover X1, manual X1, certificate X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      I want to do a test on the JB/T5376 standard, is this Thermostatic bath okay?
      [A]
      Sure
      [Q]
      What is the limit low temperature of this GDH-0520 Low Temperature Thermostatic bath?
      [A]
      TENLIN GDH-0520 meets the Temperature range of -5 to 100 ° C, with a minimum temperature of -5 ° C.
      +TenLin GDH-0520 High Accuracy Low Temperature Circulating Bath Big data
        +TenLin GDH-0520 High Accuracy Low Temperature Circulating BathSimilar products
        +TenLin GDH-0520 High Accuracy Low Temperature Circulating BathStandard
        +Navigation
        TenLin
        TENLIN GDH-0520 High Accuracy Low Temperature Circulating Bath - 5 ℃/ +/- 0.02 ℃ 20L
        Service
        Focus on online sales of Lab Testing Instruments