Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Thermostat> TenLin> TenLin DC-2006C Programmed Temperature Control Low Temperature Circulating Bath

      TENLIN DC-2006C Program Temperature Control Low Temperature Circulating Bath - 20 ℃/ +/- 0.05 ℃ 7.5L

      Temperature range -20~ 100 ℃, Temperature resolution 0.01 ℃, Temperature Fluctuation +/- 0.05 ℃, Power 1kW, Tank Volume 7.5L

      Brand
      SKU: NB036121
      China TenLin
      VS
      Genuinegoods
      • TenLin DC-2006C Programmed Temperature Control Low Temperature Circulating BathOverview

      • Specifications
      • Comments
      • FAQs
      DC-2006C
      Programmed Temperature Control Low Temperature Circulating Bath
      • TENLIN DC-2006C Program Temperature Control Low Temperature Circulating Bath - 20 ℃/ +/- 0.05 ℃ 7.5L
      • TENLIN DC-2006C Program Temperature Control Low Temperature Circulating Bath - 20 ℃/ +/- 0.05 ℃ 7.5L Figure 1
      • TENLIN DC-2006C Program Temperature Control Low Temperature Circulating Bath - 20 ℃/ +/- 0.05 ℃ 7.5L Figure 2
      Temperature range -20~ 100 ℃, Temperature resolution 0.01 ℃, Temperature Fluctuation +/- 0.05 ℃, Power 1kW, Tank Volume 7.5L

      Features

      1. Refrigeration system: It adopts low-noise air-cooled hermetic compressor unit, which has the advantages of fast refrigeration speed and strong temperature stability.

      2. Control system: new special software research and development of self-made temperature control technology, equipped with high-standard Pt100 and all imported electronic components.

      3. Circulation system: It is composed of internal and external circulation. During the external circulation, the constant temperature liquid in the tank can be introduced outside, and a second constant temperature field can be established. It can also be used as a cold source to guide the refrigerated liquid in the tank to the external experimental container to cool down. When circulating, the temperature of the liquid in the tank can be very uniform and stable.

      4. Protection system: Refrigeration has overheating and overcurrent protection. The control system has functions such as over-temperature chirp alarm, the upper limit of temperature can be set for over-temperature alarm temperature, and the load can be automatically cut off when over-temperature.

      5. High-end large LCD control instrument, easy to operate, strong temperature stability, PID can be automatically searched or manually adjusted.

      6. The accurate temperature correction function can reach 0.1°C, and the temperature fluctuation can reach up to ±0.1°C~±0.5°C (depending on the model).

      external structure

      Figure 1: Outline structure of constant temperature bath

      Figure 1: Outline structure of constant temperature bath

      Figure 2: Bath control panel

      Figure 2: Bath control panel

      Model parameters

      modeltemperature rangepowertank volume
      DC0506C-5~1000.87.5L
      DC1006C-10~1000.9
      DC2006C-20~1001
      DC3006C-30~1001.5
      DC4006C-40~1002.1
      DC0510C-5~1001.310L
      DC1010C-10~1001.5
      DC2010C-20~1001.8
      DC3010C-30~1002
      DC4010C-40~1002.1
      DC0515C-5~1002.115L
      DC1015C-10~1002.2
      DC2015C-20~1002.3
      DC3015C-30~1002.4
      DC4015C-40~1002.5
      DC0520C-5~1002.320L
      DC1020C-10~1002.4
      DC2020C-20~1002.5
      DC3020C-30~1002.6
      DC4020C-40~1002.7
      DC0530C-5~1002.530L
      DC1030C-10~1002.6
      DC2030C-20~1002.7
      DC3030C-30~1002.7
      DC4030C-40~1003
      Other parameters
      resolution0.01°C
      Volatility±0.05℃
      Heating rate0-1.2/min
      cooling rate0-0.8/min
      Unit: Temperature °C Size mm Flow L/min Power Kw


      VS

      TenLin DC-2006C Programmed Temperature Control Low Temperature Circulating BathSpecifications

      LIST VALUE
      Temperature range -20~100℃
      temperature resolution 0.01℃
      Temperature fluctuation ±0.05℃
      Dimensions 320*370*675mm
      power 1kw
      Tank Volume 7.5L
      Tank opening Dimensions 180*160mm
      groove depth 150mm
      Pump flow 6L/min
      Heating rate 0~1.2℃/min
      Cooling speed 0-0.8℃/min

      TenLin DC-2006C Programmed Temperature Control Low Temperature Circulating Bath Packing list

      host X1, cover X1, manual X1, certificate X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Is this Thermostatic bath compliant with GB/T26808 standard?
      [A]
      Thermostatic bath is suitable for GB/T26808, please consult customer service for detailed application definition
      +TenLin DC-2006C Programmed Temperature Control Low Temperature Circulating Bath Big data
        +TenLin DC-2006C Programmed Temperature Control Low Temperature Circulating BathSimilar products
        +TenLin DC-2006C Programmed Temperature Control Low Temperature Circulating BathStandard
        +Navigation
        TenLin
        TENLIN DC-2006C Program Temperature Control Low Temperature Circulating Bath - 20 ℃/ +/- 0.05 ℃ 7.5L
        Service
        Focus on online sales of Lab Testing Instruments