TENLIN DC-4030C Program Temperature Control Low Temperature Circulating Bath - 40 ℃/ +/- 0.05 ℃ 30L
Temperature range -40~ 100 ℃, Temperature resolution 0.01 ℃, Temperature Fluctuation +/- 0.05 ℃, Dimension 450 * 540 * 1090mm, Power 3kw, Tank volume 30L, Tank opening dimensions 330 * 280mm, Tank depth 230mm, Pump Flow rate 13L/min, Heating speed 0~ 1.2 ℃/min, Cooling speed 0-0.8 ℃/min.
TenLin-
SDPTOP DC-3015 Low Temperature Thermostat -30~95 ℃/15L
$ 1750.00 -
HLC-2008G Vertical High and Low Temperature Thermostat
$ 1687.00 -
NELE GX-3030 High-Temperature Circulator (Water/Oil) 30L
$ 1451.00 -
YIHENG MP-19H Circulating Heating Bath, microcomputer control, liquid filling volume 22.5L
$ 713.00 -
Kenton DC-10/10 low temperature circulating water tank -10 ℃/10L
$ 1328.00
Features
1. Refrigeration system: It adopts low-noise air-cooled hermetic compressor unit, which has the advantages of fast refrigeration speed and strong temperature stability.
2. Control system: new special software research and development of self-made temperature control technology, equipped with high-standard Pt100 and all imported electronic components.
3. Circulation system: It is composed of internal and external circulation. During the external circulation, the constant temperature liquid in the tank can be introduced outside, and a second constant temperature field can be established. It can also be used as a cold source to guide the refrigerated liquid in the tank to the external experimental container to cool down. When circulating, the temperature of the liquid in the tank can be very uniform and stable.
4. Protection system: Refrigeration has overheating and overcurrent protection. The control system has functions such as over-temperature chirp alarm, the upper limit of temperature can be set for over-temperature alarm temperature, and the load can be automatically cut off when over-temperature.
5. High-end large LCD control instrument, easy to operate, strong temperature stability, PID can be automatically searched or manually adjusted.
6. The accurate temperature correction function can reach 0.1°C, and the temperature fluctuation can reach up to ±0.1°C~±0.5°C (depending on the model).
external structure

Figure 1: Outline structure of constant temperature bath

Figure 2: Bath control panel
Model parameters
| model | temperature range | power | tank volume |
| DC0506C | -5~100 | 0.8 | 7.5L |
| DC1006C | -10~100 | 0.9 | |
| DC2006C | -20~100 | 1 | |
| DC3006C | -30~100 | 1.5 | |
| DC4006C | -40~100 | 2.1 | |
| DC0510C | -5~100 | 1.3 | 10L |
| DC1010C | -10~100 | 1.5 | |
| DC2010C | -20~100 | 1.8 | |
| DC3010C | -30~100 | 2 | |
| DC4010C | -40~100 | 2.1 | |
| DC0515C | -5~100 | 2.1 | 15L |
| DC1015C | -10~100 | 2.2 | |
| DC2015C | -20~100 | 2.3 | |
| DC3015C | -30~100 | 2.4 | |
| DC4015C | -40~100 | 2.5 | |
| DC0520C | -5~100 | 2.3 | 20L |
| DC1020C | -10~100 | 2.4 | |
| DC2020C | -20~100 | 2.5 | |
| DC3020C | -30~100 | 2.6 | |
| DC4020C | -40~100 | 2.7 | |
| DC0530C | -5~100 | 2.5 | 30L |
| DC1030C | -10~100 | 2.6 | |
| DC2030C | -20~100 | 2.7 | |
| DC3030C | -30~100 | 2.7 | |
| DC4030C | -40~100 | 3 | |
| Other parameters | |||
| resolution | 0.01°C | ||
| Volatility | ±0.05℃ | ||
| Heating rate | 0-1.2/min | ||
| cooling rate | 0-0.8/min | ||
| Unit: Temperature °C Size mm Flow L/min Power Kw | |||
TenLin DC-4030C Programmed Temperature Control Low Temperature Circulating BathSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | -40~100℃ |
| temperature resolution | 0.01℃ |
| Temperature fluctuation | ±0.05℃ |
| Dimensions | 450*540*1090mm |
| power | 3kw |
| Tank Volume | 30L |
| Tank opening Dimensions | 330*280mm |
| groove depth | 230mm |
| Pump flow | 13L/min |
| Heating rate | 0~1.2℃/min |
| Cooling speed | 0-0.8℃/min |
TenLin DC-4030C Programmed Temperature Control Low Temperature Circulating Bath Packing list
host X1, cover X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 2019-2022
- ActiveJJF 1030-2023
- ActiveGB/T 9966.2-2020
- ActiveGB/T 26809-2011
- ActiveGB/T 32710.3-2016
- ActiveJJF 1030-2010
- ActiveGB/T 26808-2011
- ActiveJB/T 5376-1991