EPK MiniTest 2500 F10 Coating Thickness Gauge Plastic-like coatings on tanks, pipes and containers
10Mm range , +/- ( 1% + 10µm) error for measurement of tanks, pipes and containers, construction of thick coatings similar to plastics.
ElektroPhysik-
Defelsko PosiTector 6000 FNTS3 Coating Thickness Gauge for coatings
$ 1998.00 -
JFL QDX film multi-purpose Detector film thickness, Hardness, adhesion and other performance detection
$ 607.00 -
Germany Nix QNix 4500 + FN5 integrated dual-use coating platings Thickness Gauge FeNFe dual-use probe 0-5000μm
$ 1345.00 -
LINSHANG LS225 Coating Thickness Gauge with N1500 probe
$ 590.00 -
DUBAN DB22-CM221 Coating Thickness Gauge with F/NF probe Measurement range 0~2000μm
$ 404.00
The MiniTest 2500 coating Thickness Gauge can be used with a wide range of transducers, different calibration methods and evaluation options for a wide range of tasks in the field of coating measurement.
Application scenarios
Non-destructive measurement covers the following measurement ranges:
0~50 mm is used for non-magnetic coating on steel
0~100 mm is used for insulating coating on non-ferrous metals
Heat-resistant probes are suitable for temperatures up to 250°C and 350°C
Pencil-shaped probes are measured in tubes and tubes
All probes are equipped with wear bars to ensure long service life on abrasive substrates.
MiniTest 2500 andMiniTest 4500Both models are equipped with a huge data memory that can store up to 2 million measured values, which can be in direct mode (MiniTest 2500) or classified as an APPLICATION-BATCH memory structure.
Data transfer to PC via USB interface; The MiniTest 4500 also offers Bluetooth connectivity.
The ergonomic design, clear display, one-touch operation and illuminated keypad, among other practical features, add high customer value to the MiniTest 2500-4500 meter series.
apply
NDT Thickness Gauges are suitable for:
Non-magnetic coating on steel
Insulating coatings on non-ferrous metals
Copper layer on an insulating substrate
Powder coatings on steel and non-ferrous metals
features
A wide range of wear-resistant probes are available for a variety of applications
Universal probes with automatic substrate inspection can quickly measure steel and non-ferrous metals
Wear-resistant special probes with virtually unlimited service life
High measurement accuracy and high repeatability
Store and evaluate the measured values
Special calibration function for rough surfaces and calibration of unknown coating (CTC method)
Principle
Magnetic induction according to DIN EN ESO 2808, Method 7C (Type F sensor)
Eddy current (CN and N-type sensors) according to DIN EN ESO 2808, Method 7D
Probe selection
| Probe model | Measuring range | resolution | Guaranteed tolerances | Minimum radius of curvature | Minimum measurement area | Minimum substrate thickness |
| FN1.6 | 0~1600μm | 0.1μm | ±(1%+1µm) | Convex 1.5mm/concave 10mm | Ø5mm | F0.5mm/N50μm |
| Non-magnetic coatings on steel and insulating coatings on non-ferrous metals. All-rounder for standard applications. | ||||||
| FN1.6/90 | 0~1600μm | 0.1μm | ±(1%+1µm) | Convex 6mm/concave 6mm | Ø5mm | F0.5mm/N50μm |
| Non-magnetic coatings on steel and insulating coatings on non-ferrous metals. It is especially suitable for measuring pipes or objects that are difficult to access. | ||||||
| F05 | 0~500μm | 0.1μm | ±(1%+0.7µm) | Convex 0.75mm/concave 5mm | Ø3mm | 0.1mm |
| Extremely thin non-ferrous metals, oxides or paints are coated on small steel workpieces. Highest precision for thin coatings. | ||||||
| F3 | 0~3000μm | 0.2μm | ±(1%+1µm) | Convex 1.5mm/concave 10mm | Ø5mm | 0.5mm |
| Non-magnetic coatings, thick coatings and enamel coatings on steel. | ||||||
| F10 | 0~10000μm | 5μm | ±(1%+10µm) | Convex 5mm/concave 16mm | Ø20mm | 1mm |
| Thick coating resembling plastic on tanks, pipes and container buildings. | ||||||
| F20 | 0~20000μm | 10μm | ±(1%+20µm) | Convex 10mm/concave 30mm | Ø40mm | 2mm |
| Thick plastic, rubber or concrete layers and corrosion-resistant layers in pipe construction. | ||||||
| F50 | 0~50000μm | 10μm | ±(3%+50µm) | Convex 50mm/concave 200mm | Ø300mm | 2mm |
| Very thick corrosion-resistant layer and anti-drum layer. | ||||||
| N02 | 0~200μm | 0.1μm | ±(1%+0.5µm) | Convex 1mm/concave 5mm | Ø2mm | 50μm |
| Precise solution for very thin coatings. Insulating layers on non-ferrous metals such as paint films, enamel or anodized layers | ||||||
| N08.Cr | 0~80μm | 0.1μm | ±(1%+1µm) | Convex 2.5mm/concave 10mm | Ø5mm | 100μm |
| A chromium plating layer with a maximum thickness of 80 μm is measured on a copper substrate | ||||||
| N10 | 0~10000μm | 10μm | ±(1%+25µm) | Convex 25mm/concave 100mm | Ø50mm | 50μm |
| It is used to measure the insulating layers of rubber, plastic, glass and other non-ferrous metals. | ||||||
| N20 | 0~20000μm | 10μm | ±(1%+50µm) | Convex 25mm/concave 100mm | Ø70mm | 50μm |
| Insulating coatings on non-ferrous metals, e.g. rubber, plastic, glass. | ||||||
| N100 | 0~100000μm | 100μm | ±(1%+0.3µm) | Convex 100mm/plane | Ø200mm | 50μm |
| Thick insulation and composites on non-ferrous metals. | ||||||
ElektroPhysik MiniTest 2500 F10 Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Magnetic Induction |
| probe | F10 |
| Measurement range | 0~10000μm |
| Resolution | 5μm |
| guaranteed tolerance | ±(1%+10µm) |
| Minimum radius of curvature | Convex 5mm/Concave 16mm |
| Minimum measurement surface | Φ20mm |
| Minimum substrate thickness | 1mm |
| Data storage | 200W |
| statistical function | kvar, n, max., min. |
| Calibrated mode | Factory calibrated, zero and up to four calibrated points |
| Unit display | μm, mm, cm, mils, inch |
| Interface | USB |
| Power Supply | 3 x AA (LR06) batteries, USB |
| Display screen | 53 * 46 mm, backlit |
| Protection level | IP65 |
ElektroPhysik MiniTest 2500 F10 Coating Thickness Gauge Packing list
Main unit, calibrated foil and reference board, operating instructions CD-ROM, soft bag and shoulder strap, data transmission software.
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Application of Coating Thickness Gauge in Textile Material Measurement
- About Wet Film and Dry Film Coating Thickness Measurement
- Application Value of Coating Thickness Gauge in Steel Structure Coating Construction
- Common precautions for the selection of coating Thickness Gauges
- Application of nondestructive testing coating thickness in Coating construction
- Principle and Application Scope of Copper Plate Magnetic Induction Thickness Gauge
- Basic principle and application scenario of steel Coating Thickness Gauge
- Principle, Application and Selection of Coating Thickness Gauge for inner wall of small pipe
- Principle, application and selection of stainless steel paints Coating Thickness Gauge
- Principle, application and selection of traffic coatings Coating Thickness Gauge
- ActiveQJ 990.3A-2011
- ActiveGB/T 1727-2021
- ActiveHG/T 20720-2020
- ActiveHG/T 3369-2003
- ActiveSY/T 0315-2013


MiniTest 2500 F10