HONGKE PQX-400 Artificial Climate Chamber 400L
Volume 400L, refrigerant R134A, Temperature range with light 10-50 ℃; no light 5-50 ℃, light intensity 0~12000LX, humidity control range 50%~ 95% RH, shelf (standard) 3pcs, Timer Range 1-9999min, liner size 590x580x1140mm
HongKe-
Hengli RG-250 Artificial climate Chamber 250L
$ 3444.00 -
YIHENG MGC-450HP-2L Artificial Climate Chamber
$ 4542.00 -
YIHENG MGC-350HP Artificial climate Chamber Programmable 300L/three-sided lighting
$ 2993.00 -
YIHENG MGC-800H Artificial climate Chamber 800L/Shelf type light
$ 6917.00 -
HUITAI HQH-150 Environmental Chamber 150L mirror stainless steel liner three-sided light
$ 1686.00
Application
PQX/type series Artificial climate Chamber is the equipment for the growth and cultivation of cell tissue, seed germination, planting and seedling cultivation, breeding of insects and small animals, cultivation of microorganisms and anti-biological preservation of wood, and performance tests of building materials, especially suitable for bioengineering, medical research, agriculture, etc. It is a device for constant temperature, constant humidity, and light experiment cultivation for production and scientific research in the fields of science, aquatic products, and animal husbandry.
Features
Adopt microcomputer technology programmable control method to simulate natural climate by setting various parameters (including temperature, humidity, light, time) and performing day/night cycle work. It has excellent control performance and anti-interference ability to meet different dynamic conditions. , Plant production and various biological preservation needs.
Microcomputer automatic control, touch switch, easy to operate, programmable control mode, temperature, humidity and illuminance (adjustable) can be set independently during the day and night, with power-off memory function, intelligent constant temperature control system, quick control to the response High temperature accuracy, good performance by adopting internal dehumidification method, convenient and reliable, soft wind speed in the air duct ventilation studio, uniform temperature and humidity, with over temperature sensor abnormal protection function, and independent air duct over temperature protection device to ensure the safety of instruments and samples , The four corners of the box liner are semi-circular arc-shaped, using mirror or brushed stainless steel.
Model comparison
| model | volume | temperature uniformity | temperature fluctuation |
| PQX-160 | 160L | ±1℃ | ±0.5℃ |
| PQX-250 | 250L | ±1℃ | ±0.5℃ |
| PQX-300 | 300L | ±2℃ | ±1℃ |
| PQX-400 | 400L | ±2℃ | ±1℃ |
| Other parameters | |||
| Refrigerant | R134A | ||
| ambient temperature | 5-35℃ | ||
| temperature range | With light 10-50°C Without light 5-50°C | ||
| light intensity | 0-12000LX adjustable | ||
| Humidity range | 50%~95%RH | ||
| humidity fluctuation | ±5-±8%RH | ||
| power supply | 220V 50HZ | ||
| Timer Range | 1-9999min | ||
| Carrier | 3pcs | ||
HongKe PQX-400 Artificial Climate ChamberSpecifications
| LIST | VALUE |
|---|---|
| Volume | 400L |
| refrigerant | R134A |
| Environment temperature | 5-35℃ |
| Temperature range | Light 10-50 ℃ No light 5-50 ℃ |
| light intensity | 0~12000LX adjustable |
| Temperature Uniformity | ±2℃ |
| Temperature fluctuation | ±1℃ |
| Humidity control range | 50%~95%RH |
| Humidity fluctuation | ±5-±8%RH |
| Power | 220V 50HZ |
| Maximum power consumption | 1100W |
| Shelf | 3 |
| Timer | 1-9999min |
| Liner size | 590x580x1140mm |
| Dimensions | 770x790x1730mm |
HongKe PQX-400 Artificial Climate Chamber Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


PQX-400