Qiwei PH-20W pen acidity meter, small size, easy to carry
Qiwei PH-20W pH meter is a pen acidity meter with an accurate measurement of ± 0.1pH, which can measure pH and temperature at the same time. PH-20W pen acidity meter is an external electrode. Accuracy up to ± 0.1pH.
QiWei-
FANGZHOU PHS-320 Intelligent Multifunctional Acidity Meter GLP Function Management 0.001pH/0.01mV
$ 651.00 -
PH828 + pen pH meter
$ 112.00 -
Kodida CT-6658 PH/ORP Controller, Industrial pHmeter with electrodes CT-1001
$ 240.00 -
FANGZHOU FZ-751 Semi-solid PH electrode test cheese, flour products, meat products, fruit pH value
$ 392.00 -
FANGZHOU FZ-843 PH electrode with temperature probe, high temperature strong alkali solution test
$ 287.00
Introduction
Qiwei PH-20W PH meter is a pen-type acidity meter, the measurement accuracy is ±0.1pH, and it can measure PH value and temperature value at the same time. The PH-20W pen-type acidity meter is small in size and easy to carry, and is often used in outdoor or field test operations. It is suitable for monitoring the pH value of tap water, aquaculture, environmental protection, agriculture, printing and dyeing, electroplating, beverages and scientific research units, and the measurement is accurate and reliable. PH-20W pen type acidity meter is an external electrode.
Pictures



QiWei PH-20W PH Meter (pen)Specifications
| LIST | VALUE |
|---|---|
| PH range | 0.1~14pH |
| PH measurement Accuracy | ±0.1pH |
| Power | 1.5V battery (LR44) * 4PCS |
| Dimensions | F40 * 185mm |
| Weight | 88g |
| Allowable environment temperature | 0~50℃ |
| resolution | 0.1pH |
| PH calibrated | PH: 25 ℃ three point calibrated (4.0, 6.9, 9.2) |
| temperature resolution | 0.1℃(1℉) |
| Temperature measurement Accuracy | 1℃ |
| Temperature Measurement range | 0~50℃/32~122℉ |
QiWei PH-20W PH Meter (pen) Packing list
Host x1, Buffer reagent x3, Encasement box x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 3324-2024
- ActiveGB/T 2394-2024
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveSN/T 1523-2005
- ActiveQB/T 2724-2018
- ActiveJB/T 6203-2017
- ActiveNY/T 82.7-1988
- Active 098-2007
- ActiveGB/T 1601-2023
- ActiveGB/T 18920-2020
- ActiveGB/T 1576-2018
- ActiveGB/T 6920-1986
- ActiveGB/T 13580.4-1992
- AbolishGB/T 1601-1993
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 12010.4-2010
- ActiveGB/T 2390-2013


PH-20W