Qiwei PH-20W pen acidity meter, small size, easy to carry
Qiwei PH-20W pH meter is a pen acidity meter with an accurate measurement of ± 0.1pH, which can measure pH and temperature at the same time. PH-20W pen acidity meter is an external electrode. Accuracy up to ± 0.1pH.
QiWei-
LEICI 962221 Ultra-pure water pH composite electrode Suitable for ultra-low conductivity water samples such as pure water and deionized water
$ 265.00 -
Online ph acidity meter AOLILONG PHG-2 industrial acidity meter
$ 240.00 -
DDKSIC 201FLAT planar pH electrode planar samples, such as skin paper fermentation dough foster base, etc
$ 97.00 -
HANNA HI981401N pH Determination Controller, Suspended
$ 319.00 -
LEICI 962121 Low Conductivity Detector pH composite electrode for low conductivity water samples with conductivity above 100 µS/cm
$ 202.00
Introduction
Qiwei PH-20W PH meter is a pen-type acidity meter, the measurement accuracy is ±0.1pH, and it can measure PH value and temperature value at the same time. The PH-20W pen-type acidity meter is small in size and easy to carry, and is often used in outdoor or field test operations. It is suitable for monitoring the pH value of tap water, aquaculture, environmental protection, agriculture, printing and dyeing, electroplating, beverages and scientific research units, and the measurement is accurate and reliable. PH-20W pen type acidity meter is an external electrode.
Pictures



QiWei PH-20W PH Meter (pen)Specifications
| LIST | VALUE |
|---|---|
| PH range | 0.1~14pH |
| PH measurement Accuracy | ±0.1pH |
| Power | 1.5V battery (LR44) * 4PCS |
| Dimensions | F40 * 185mm |
| Weight | 88g |
| Allowable environment temperature | 0~50℃ |
| resolution | 0.1pH |
| PH calibrated | PH: 25 ℃ three point calibrated (4.0, 6.9, 9.2) |
| temperature resolution | 0.1℃(1℉) |
| Temperature measurement Accuracy | 1℃ |
| Temperature Measurement range | 0~50℃/32~122℉ |
QiWei PH-20W PH Meter (pen) Packing list
Host x1, Buffer reagent x3, Encasement box x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 3324-2024
- ActiveGB/T 2394-2024
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveSN/T 1523-2005
- ActiveQB/T 2724-2018
- ActiveJB/T 6203-2017
- ActiveNY/T 82.7-1988
- Active 098-2007
- ActiveGB/T 1601-2023
- ActiveGB/T 18920-2020
- ActiveGB/T 1576-2018
- ActiveGB/T 6920-1986
- ActiveGB/T 13580.4-1992
- AbolishGB/T 1601-1993
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 12010.4-2010
- ActiveGB/T 2390-2013


PH-20W