Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Gas detector> Skyeaglee> Skyeaglee SK/MIC-800-CO-Y/65000 Portable carbon monoxide Detector

      SK/MIC-800-CO-Y/65000 portable carbon monoxide Detector electrochemistry 65000ppm

      Detection gas carbon monoxide CO, range 0~65000ppm, resolution 0.1ppm, detection principle electrochemistry, Operating Mode pump suction, sampling accuracy ≤ 3% F.S, repeability 3% F.S

      Brand
      SKU: NB037069
      China Skyeaglee
      VS
      Genuinegoods
      • Skyeaglee SK/MIC-800-CO-Y/65000 Portable carbon monoxide DetectorOverview

      • Specifications
      • Comments
      • FAQs
      SK/MIC-800-CO-Y/65000
      Portable carbon monoxide Detector
      • SK/MIC-800-CO-Y/65000 portable carbon monoxide Detector electrochemistry 65000ppm
      • SK/MIC-800-CO-Y/65000 portable carbon monoxide Detector electrochemistry 65000ppm Figure 1
      • SK/MIC-800-CO-Y/65000 portable carbon monoxide Detector electrochemistry 65000ppm Figure 2
      Detection gas carbon monoxide CO, range 0~65000ppm, resolution 0.1ppm, detection principle electrochemistry, Operating Mode pump suction, sampling accuracy ≤ 3% F.S, repeability 3% F.S

      SK/MIC-800 series handheld Gas Detectors use EFM ultra-low power consumption 32-bit ARM, the sensor adopts a professional imported catalytic combustion sensor, and the sensor part uses a two-stage high-precision low-temperature drift amplifier and a highly stable power supply. The processing circuit ensures that the instrument detects fast, accurate, stable and repeatable, making the instrument the most professional and stable Gas Detector and leak Detector in the world. The instrument adopts a large full-color 3.5-inch TFT screen, supports Chinese and English, and graphic menu operation, which is easy for users to operate.

      Features

      Adopt imported high-precision sensors;

      High-precision low-temperature drift amplifiers and stable power processing circuits are used;

      TFT3.5-inch full-color display, graphical menu, Chinese and English display, providing real-time detection trend analysis chart;

      Data storage function, can store 200,000 sets of data, and the storage interval is adjustable;

      USB interface for high-speed data transmission, print data can be downloaded;

      Built-in long-life imported micro sampling pump, adjust the cleaning air circuit through gear;

      Comply with explosion-proof certification, explosion-proof grade: Exia Ⅱ CT4

      Shell two-color mold: non-slip, waterproof, dustproof, explosion-proof

      Functions

      Pump suction detection method: divided into three gears, low-grade, medium-grade and high-grade

      Monitor the concentration of gases in the environment or confined spaces and alarm

      With self-calibration function, zero-point calibration function, multi-point calibration function

      With temperature and pressure compensation, it can well realize the compensation of gas concentration in different temperature and pressure environments

      One-click factory reset function can avoid the trouble of misoperation

      Gas concentration unit LEL,% LEL can quickly switch the display;

      With self-programming function, alarm parameters, STEL and TWA function parameters can be set

      There are two detection modes: normal detection mode and patrol mode;

      The detection gas circuit has an automatic cleaning function, which automatically prompts the failure of the instrument, the expiration and failure functions of the sensor calibration, and the real-time display characteristics of the detected maximum value, STEL, TWA and concentration value

      Dimensions

      SK/MIC-800 Portable Formaldehyde Detector1


      Series

      GasRangeMax. errorMin. readingResponse timeT90
      EX
      0-100%LEL<±3%(F.S)0.1%LEL≤10s
      0-100%Vol<±3%(F.S)0.1%Vol≤10s
      CH40-100%LEL<±3%(F.S)0.1%LEL≤10s
      0-100%Vol<±3%(F.S)0.1%Vol≤10s
      O20-30%Vol<±3%(F.S)0.01%Vol≤10s
      0-100%Vol<±3%(F.S)0.01%Vol≤10s
      0-5000ppm<±3%(F.S)1ppm≤30s
      N20-100%Vol<±3%(F.S)0.01%Vol≤10s
      CO0-100ppm<±3%(F.S)0.1ppm≤25s
      0-1000ppm<±3%(F.S)0.1ppm≤25s
      0-2000ppm<±3%(F.S)0.1ppm≤25s
      0-20000ppm<±3%(F.S)1ppm≤25s
      0-100000ppm<±3%(F.S)1ppm≤25s
      CO20-500ppm<±3%(F.S)1ppm≤20s
      0-2000ppm<±3%(F.S)1ppm≤20s
      0-5000ppm<±3%(F.S)1ppm≤20s
      0-50000ppm<±3%(F.S)1ppm≤30s
      0-20%Vol<±3%(F.S)0.01%Vol≤30s
      0-100%Vol<±3%(F.S)0.01%Vol≤30s
      CH2O0-10ppm<±3%(F.S)0.001ppm≤30s
      0-10ppm<±3%(F.S)0.01ppm≤30s
      0-100ppm<±3%(F.S)0.01ppm≤30s
      0-5000ppm<±3%(F.S)1ppm≤50s
      O30-1ppm<±3%(F.S)0.001ppm≤20s
      0-5ppm<±3%(F.S)0.001ppm≤20s
      0-50ppm<±3%(F.S)0.01ppm≤20s
      0-100ppm<±3%(F.S)0.01ppm≤20s
      0-2000ppm<±3%(F.S)0.1ppm≤30s
      0-30000ppm<±3%(F.S)1ppm≤30s
      0-20mg/L<±3%(F.S)0.01mg/L≤30s
      H2S0-10ppm<±3%(F.S)0.001ppm≤30s
      0-50ppm<±3%(F.S)0.01ppm≤30s
      0-100ppm<±3%(F.S)0.01ppm≤30s
      0-2000ppm<±3%(F.S)0.1ppm≤30s
      0-10000ppm<±3%(F.S)1ppm≤45s
      SO20-10ppm<±3%(F.S)0.001ppm≤30s
      0-20ppm<±3%(F.S)0.01ppm≤30s
      0-100ppm<±3%(F.S)0.01ppm≤30s
      0-500ppm<±3%(F.S)0.1ppm≤30s
      0-2000ppm<±3%(F.S)0.1ppm≤30s
      0-10000ppm<±3%(F.S)1ppm≤30s
      NO0-10ppm<±3%(F.S)0.001ppm≤30s
      0-100ppm<±3%(F.S)0.01ppm≤30s
      0-2000ppm<±3%(F.S)0.1ppm≤30s
      0-5000ppm<±3%(F.S)1ppm≤30s
      NO20-10ppm<±3%(F.S)0.001ppm≤25s
      0-100ppm<±3%(F.S)0.01ppm≤25s
      0-1000ppm<±3%(F.S)0.1ppm≤30s
      0-5000ppm<±3%(F.S)1ppm≤30s
      NOX0-10ppm<±3%(F.S)0.001ppm≤30s
      0-100ppm<±3%(F.S)0.01ppm≤30s
      0-2000ppm<±3%(F.S)0.1ppm≤30s
      0-5000ppm<±3%(F.S)1ppm≤30s
      CL20-10ppm<±3%(F.S)0.001ppm≤30s
      0-20ppm<±3%(F.S)0.01ppm≤30s
      0-200ppm<±3%(F.S)0.1ppm≤30s
      0-2000ppm<±3%(F.S)0.1ppm≤30s
      NH30-50ppm<±3%(F.S)0.01ppm≤30s
      0-100ppm<±3%(F.S)0.01ppm≤30s
      0-1000ppm<±3%(F.S)0.1ppm≤30s
      0-5000ppm<±3%(F.S)1ppm≤30s
      0-100%LEL<±3%(F.S)0.1%LEL≤10s
      H20-100%LEL<±3%(F.S)0.1%LEL≤10s
      0-1000ppm<±3%(F.S)0.1ppm≤30s
      0-20000ppm<±3%(F.S)1ppm≤30s
      0-40000ppm<±3%(F.S)1ppm≤30s
      0-100%Vol<±3%(F.S)0.01%Vol≤20s
      He0-100%Vol<±3%(F.S)0.01%Vol≤20s
      Ar0-100%Vol<±3%(F.S)0.01%Vol≤20s
      Xe0-100%Vol<±3%(F.S)0.01%Vol≤20s
      HCN0-30ppm<±3%(F.S)0.01ppm≤30s
      0-100ppm<±3%(F.S)0.01ppm≤30s
      HCL0-20ppm<±3%(F.S)0.01ppm≤30s
      0-200ppm<±3%(F.S)0.1ppm≤30s
      PH30-5ppm<±3%(F.S)0.001ppm≤30s
      0-25ppm<±3%(F.S)0.01ppm≤30s
      0-2000ppm<±3%(F.S)1ppm≤30s
      CLO20-1ppm<±3%(F.S)0.001ppm≤30s
      0-10ppm<±3%(F.S)0.01ppm≤30s
      0-200ppm<±3%(F.S)0.01ppm≤30s
      ETO0-100ppm<±3%(F.S)0.01ppm≤30s
      0-1000ppm<±3%(F.S)0.1ppm≤30s
      0-100%LEL<±3%(F.S)1%LEL≤30s
      COCL20-1ppm<±3%(F.S)0.001ppm≤20s
      0-50ppm<±3%(F.S)0.01ppm≤20s
      SiH40-1ppm<±3%(F.S)0.001ppm≤30s
      0-50ppm<±3%(F.S)0.01ppm≤30s
      F20-1ppm<±3%(F.S)0.001ppm≤30s
      0-10ppm<±3%(F.S)0.01ppm≤30s
      0-50ppm<±3%(F.S)0.01ppm≤30s
      HF0-10ppm<±3%(F.S)0.01ppm≤30s
      0-50ppm<±3%(F.S)0.01ppm≤30s
      HBr0-50ppm<±3%(F.S)0.01ppm≤30s
      B2H60-10ppm<±3%(F.S)0.001ppm≤30s
      AsH30-1ppm<±3%(F.S)0.001ppm≤30s
      0-10ppm<±3%(F.S)0.01ppm≤30s
      0-50ppm<±3%(F.S)0.01ppm≤30s
      GeH40-2ppm<±3%(F.S)0.001ppm≤30s
      0-20ppm<±3%(F.S)0.01ppm≤30s
      N2H4
      0-1ppm<±3%(F.S)0.001ppm≤30s
      0-300ppm<±3%(F.S)0.1ppm≤30s
      THT0-100mg/m3<±3%(F.S)0.01mg/m3≤60s
      Br20-10ppm<±3%(F.S)0.001ppm≤30s
      0-100ppm<±3%(F.S)0.01ppm≤30s
      0-2000ppm<±3%(F.S)1ppm≤30s
      C2H20-100%LEL<±3%(F.S)0.1%LEL≤30s
      0-100ppm<±3%(F.S)0.01ppm≤30s
      0-1000ppm<±3%(F.S)0.1ppm≤30s
      C2H40-100%LEL<±3%(F.S)0.1%LEL≤30s
      0-100ppm<±3%(F.S)0.01ppm≤30s
      0-2000ppm<±3%(F.S)0.1ppm≤30s
      CH3CHO0-10ppm<±3%(F.S)0.01ppm≤30s
      C2H6O0-100ppm<±3%(F.S)0.01ppm≤30s
      0-2000ppm<±3%(F.S)1ppm≤30s
      CH6O0-100ppm<±3%(F.S)0.01ppm≤30s
      0-2000ppm<±3%(F.S)1ppm≤30s
      CS20-50ppm<±3%(F.S)0.01ppm≤30s
      0-5000ppm<±3%(F.S)0.01ppm≤30s
      C3H3N0-50ppm<±3%(F.S)0.01ppm≤30s
      0-2000ppm<±3%(F.S)1ppm≤30s
      CH5N0-50ppm<±3%(F.S)0.01ppm≤30s
      I20-50ppm<±3%(F.S)0.01ppm≤30s
      C8H80-200ppm<±3%(F.S)0.1ppm≤30s
      0-5000ppm<±3%(F.S)1ppm≤30s
      C2H3CL0-100ppm<±3%(F.S)0.01ppm≤30s
      C2HCL30-100ppm<±3%(F.S)0.01ppm≤30s
      C2CL40-100ppm<±3%(F.S)0.01ppm≤30s
      N2O0-100ppm<±3%(F.S)0.01ppm≤30s
      NF30-100ppm<±3%(F.S)0.01ppm≤30s
      H2O20-100ppm<±3%(F.S)0.01ppm≤30s
      CH3Br0-100ppm<±3%(F.S)0.01ppm≤30s
      0-30000ppm<±3%(F.S)1ppm≤30s
      0-200g/m3<±3%(F.S)0.1g/m3≤30s
      SO2F20-100ppm<±3%(F.S)0.01ppm≤30s
      0-5000ppm<±3%(F.S)1ppm≤30s
      0-10000ppm<±3%(F.S)1ppm≤30s
      C6H60-10ppm<±3%(F.S)0.01ppm≤30s
      0-100ppm<±3%(F.S)0.01ppm≤30s
      0-2000ppm<±3%(F.S)1ppm≤30s


      VS

      Skyeaglee SK/MIC-800-CO-Y/65000 Portable carbon monoxide DetectorSpecifications

      LIST VALUE
      Detection gas Carbon monoxide CO
      range 0~65000ppm
      Resolution 0.1ppm
      Sensors principle electrochemistry
      Operating Mode Pump suction
      Sampling Accuracy ≦3%F.S
      Sexual repeability 3%F.S
      Long term drift ≤±3% (F.S/年)
      Response time ≤10S
      Warm-up period 30S
      Operating Current ≤50mA
      data storage USB data collection, 300,000 group information storage
      service life 3 years
      Operating Pressure 86kpa-106kpa
      Shell material Anti-corrosion plastic, aluminum alloy
      Operating temperature -30~50℃
      Environment humidity 10~95% RH non-condensing
      Storage temperature -30~70℃
      Dimensions 228 * 84 * 50.5mm excluding sampling tube
      Weight 1.5kg
      Explosion-proof sign Exia II CT4

      Skyeaglee SK/MIC-800-CO-Y/65000 Portable carbon monoxide Detector Packing list

      Portable detector X1, sampling tube X1, certificate X1, detector manual X1, charger X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Is the price listed on the website the final cost for overseas purchases?
      [A]
      No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
      [Q]
      What is the specific process for purchasing the product?
      [A]
      First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
      [Q]
      What should I do if the instrument I purchase needs repair?
      [A]
      After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
      +Skyeaglee SK/MIC-800-CO-Y/65000 Portable carbon monoxide Detector Big data
        +Skyeaglee SK/MIC-800-CO-Y/65000 Portable carbon monoxide DetectorSimilar products
        +Skyeaglee SK/MIC-800-CO-Y/65000 Portable carbon monoxide DetectorStandard
        +Navigation
        Skyeaglee
        SK/MIC-800-CO-Y/65000 portable carbon monoxide Detector electrochemistry 65000ppm
        Service
        Focus on online sales of Lab Testing Instruments