Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Gas detector> Skyeaglee> Skyeaglee SK/MIC-800-F2-Y/10000 Portable fluorine Detector

      SK/MIC-800-F2-Y/10000 Portable fluorine Gas Detector, fluorine gas F2 electrochemistry 10000ppm

      Detection gas fluorine F2, range 0~10000ppm, resolution 0.1ppm, detection principle electrochemistry, Operating Mode pump suction, sampling accuracy ≤ 3% F.S, repeability 3% F.S

      Brand
      SKU: NB037150
      China Skyeaglee
      VS
      Genuinegoods
      • Skyeaglee SK/MIC-800-F2-Y/10000 Portable fluorine DetectorOverview

      • Specifications
      • Comments
      • FAQs
      SK/MIC-800-F2-Y/10000
      Portable fluorine Detector
      • SK/MIC-800-F2-Y/10000 Portable fluorine Gas Detector, fluorine gas F2 electrochemistry 10000ppm
      • SK/MIC-800-F2-Y/10000 Portable fluorine Gas Detector, fluorine gas F2 electrochemistry 10000ppm Figure 1
      • SK/MIC-800-F2-Y/10000 Portable fluorine Gas Detector, fluorine gas F2 electrochemistry 10000ppm Figure 2
      Detection gas fluorine F2, range 0~10000ppm, resolution 0.1ppm, detection principle electrochemistry, Operating Mode pump suction, sampling accuracy ≤ 3% F.S, repeability 3% F.S

      SK/MIC-800 Series Handheld Gas Detector ApplicationsEFM ultra-low power consumption 32-bit ARM, the sensor adopts a professional imported catalytic combustion sensor, sensor partThe two-stage high-precision low-temperature drifting amplifier and high-stability power processing circuit are used to ensure fast detection and accurate measurement of the instrumentAccurate, stable and repeatable, the instrument has reached the international professional and most stable Gas Detector and leak Detector. The instrument adopts ultraLarge full-color 3.5-inch TFT screen, support Chinese and English graphic menu operation, easy for users to operate.

      Features

      • Imported high-precision sensors;

      • It uses a high-precision low-temperature drifting amplifier and a stable power processing circuit.

      • TFT 3.5-inch full-color display, graphic menu, Chinese and English display, providing real-time detection trend analysis chart;

      • Data storage function, which can store 200,000 sets of data, and the storage interval time is adjustable;

      • USB interface for high-speed data transfer, which can download and print data;

      • Built-in long-life imported micro sampling pump, cleaning gas path through gear adjustment;

      • Explosion-proof qualification certification, explosion-proof grade: ExiaII.CT4

      • Shell two-color mold: non-slip, waterproof, dustproof, explosion-proof

      Features

      • Pumping detection method: divided into three gears, low-grade, mid-range and high-grade

      • Monitor the concentration of gases in the environment or confined spaces and give alarms

      • With self-calibration function, zero point calibration function, multi-point calibration function

      • With temperature and pressure compensation, it can well realize the compensation of gas concentration in different temperature and pressure environments

      • One-click factory reset function, which can avoid the trouble of misoperation

      • Gas concentration unit LEL, %LEL can be quickly switched to display;

      • It has a self-programming function and can set alarm parameters, STEL and TWA function parameters

      • It has two detection modes: normal detection mode and patrol mode;

      • The detection gas path has the function of automatic cleaning, which automatically prompts the failure of the instrument, the function of sensor calibration expiration and failure, and the maximum detectionValue, STEL, TWA and concentration values are displayed in real time

      Exterior Dimension Drawing

      Details of SK/MIC-800-F2-Y/10000 Portable Fluorine Detector Figure 1


      Series selection

      Detection of gasesRangeMaximum allowable errorMinimum readingResponse timeT90
      Combustible (EX)0-100%LEL<±3%(F.S)0.1%LEL≤ 10 seconds
      Combustible (EX)0-100%Vol<±3%(F.S)0.1%Vol≤ 10 seconds
      Methane (CH4)0-100%LEL<±3%(F.S)0.1%LEL≤ 10 seconds
      Methane (CH4)0-100%Vol<±3%(F.S)0.1%Vol≤ 10 seconds
      Oxygen (O2)0-30%Vol<±3%(F.S)0.01%Vol≤ 10 seconds
      Oxygen (O2)0-100%Vol<±3%(F.S)0.01%Vol≤ 10 seconds
      Oxygen (O2)0-5000ppm<±3%(F.S)1ppm≤ 30 seconds
      Nitrogen (N2)0-100%Vol<±3%(F.S)0.01%Vol≤ 10 seconds
      Carbon Monoxide (CO)0-100ppm<±3%(F.S)0.1ppm≤ 25 seconds
      Carbon Monoxide (CO)0-1000ppm<±3%(F.S)0.1ppm≤ 25 seconds
      Carbon Monoxide (CO)0-2000ppm<±3%(F.S)0.1ppm≤ 25 seconds
      Carbon Monoxide (CO)0-20000ppm<±3%(F.S)1ppm≤ 25 seconds
      Carbon Monoxide (CO)0-100000ppm<±3%(F.S)1ppm≤ 25 seconds
      Carbon dioxide (CO2)0-500ppm<±3%(F.S)1ppm≤ 20 seconds
      Carbon dioxide (CO2)0-2000ppm<±3%(F.S)1ppm≤ 20 seconds
      Carbon dioxide (CO2)0-5000ppm<±3%(F.S)1ppm≤ 20 seconds
      Carbon dioxide (CO2)0-50000ppm<±3%(F.S)1ppm≤ 30 seconds
      Carbon dioxide (CO2)0-20%Vol<±3%(F.S)0.01%Vol≤ 30 seconds
      Carbon dioxide (CO2)0-100%Vol<±3%(F.S)0.01%Vol≤ 30 seconds
      Formaldehyde (CH2O)0-10ppm<±3%(F.S)0.001ppm≤ 30 seconds
      Formaldehyde (CH2O)0-10ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Formaldehyde (CH2O)0-100ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Formaldehyde (CH2O)0-5000ppm<±3%(F.S)1ppm≤ 50 seconds
      Ozone (O3)0-1ppm<±3%(F.S)0.001ppm≤ 20 seconds
      Ozone (O3)0-5ppm<±3%(F.S)0.001ppm≤ 20 seconds
      Ozone (O3)0-50ppm<±3%(F.S)0.01ppm≤ 20 seconds
      Ozone (O3)0-100ppm<±3%(F.S)0.01ppm≤ 20 seconds
      Ozone (O3)0-2000ppm<±3%(F.S)0.1ppm≤ 30 seconds
      Ozone (O3)0-30000ppm<±3%(F.S)1ppm≤ 30 seconds
      Ozone (O3)0-20mg/L<±3%(F.S)0.01mg/L≤ 30 seconds
      Ozone Water (O3)0-20mg/L<±3%(F.S)0.01mg/L≤ 30 seconds
      Hydrogen sulfide (H2S)0-10ppm<±3%(F.S)0.001ppm≤ 30 seconds
      Hydrogen sulfide (H2S)0-50ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Hydrogen sulfide (H2S)0-100ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Hydrogen sulfide (H2S)0-2000ppm<±3%(F.S)0.1ppm≤ 30 seconds
      Hydrogen sulfide (H2S)0-10000ppm<±3%(F.S)1ppm≤ 45 seconds
      Sulphur dioxide (SO2)0-10ppm<±3%(F.S)0.001ppm≤ 30 seconds
      Sulphur dioxide (SO2)0-20ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Sulphur dioxide (SO2)0-100ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Sulphur dioxide (SO2)0-500ppm<±3%(F.S)0.1ppm≤ 30 seconds
      Sulphur dioxide (SO2)0-2000ppm<±3%(F.S)0.1ppm≤ 30 seconds
      Sulphur dioxide (SO2)0-10000ppm<±3%(F.S)1ppm≤ 30 seconds
      Nitric Oxide (NO)0-10ppm<±3%(F.S)0.001ppm≤ 30 seconds
      Nitric Oxide (NO)0-100ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Nitric Oxide (NO)0-2000ppm<±3%(F.S)0.1ppm≤ 30 seconds
      Nitric Oxide (NO)0-5000ppm<±3%(F.S)1ppm≤ 30 seconds
      Nitrogen dioxide (NO2)0-10ppm<±3%(F.S)0.001ppm≤ 25 seconds
      Nitrogen dioxide (NO2)0-100ppm<±3%(F.S)0.01ppm≤ 25 seconds
      Nitrogen dioxide (NO2)0-1000ppm<±3%(F.S)0.1ppm≤ 30 seconds
      Nitrogen dioxide (NO2)0-5000ppm<±3%(F.S)1ppm≤ 30 seconds
      Nitrogen Oxides (NOX)0-10ppm<±3%(F.S)0.001ppm≤ 30 seconds
      Nitrogen Oxides (NOX)0-100ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Nitrogen Oxides (NOX)0-2000ppm<±3%(F.S)0.1ppm≤ 30 seconds
      Nitrogen Oxides (NOX)0-5000ppm<±3%(F.S)1ppm≤ 30 seconds
      Chlorine (CL2)0-10ppm<±3%(F.S)0.001ppm≤ 30 seconds
      Chlorine (CL2)0-20ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Chlorine (CL2)0-200ppm<±3%(F.S)0.1ppm≤ 30 seconds
      Chlorine (CL2)0-2000ppm<±3%(F.S)0.1ppm≤ 30 seconds
      Ammonia (NH3)0-50ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Ammonia (NH3)0-100ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Ammonia (NH3)0-1000ppm<±3%(F.S)0.1ppm≤ 30 seconds
      Ammonia (NH3)0-5000ppm<±3%(F.S)1ppm≤ 30 seconds
      Ammonia (NH3)0-100%LEL<±3%(F.S)0.1%LEL≤ 10 seconds
      Hydrogen (H2)0-100%LEL<±3%(F.S)0.1%LEL≤ 10 seconds
      Hydrogen (H2)0-1000ppm<±3%(F.S)0.1ppm≤ 30 seconds
      Hydrogen (H2)0-20000ppm<±3%(F.S)1ppm≤ 30 seconds
      Hydrogen (H2)0-40000ppm<±3%(F.S)1ppm≤ 30 seconds
      Hydrogen (H2)0-100%Vol<±3%(F.S)0.01%Vol≤ 20 seconds
      Helium (He)0-100%Vol<±3%(F.S)0.01%Vol≤ 20 seconds
      Argon (Ar)0-100%Vol<±3%(F.S)0.01%Vol≤ 20 seconds
      Xenon (Xe)0-100%Vol<±3%(F.S)0.01%Vol≤ 20 seconds
      Hydrogen cyanide (HCN)0-30ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Hydrogen cyanide (HCN)0-100ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Hydrogen chloride (HCL)0-20ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Hydrogen chloride (HCL)0-200ppm<±3%(F.S)0.1ppm≤ 30 seconds
      Phosphine (PH3)0-5ppm<±3%(F.S)0.001ppm≤ 30 seconds
      Phosphine (PH3)0-25ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Phosphine (PH3)0-2000ppm<±3%(F.S)1ppm≤ 30 seconds
      Chlorine dioxide (CLO2)0-1ppm<±3%(F.S)0.001ppm≤ 30 seconds
      Chlorine dioxide (CLO2)0-10ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Chlorine dioxide (CLO2)0-200ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Ethylene Oxide (ETO)0-100ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Ethylene Oxide (ETO)0-1000ppm<±3%(F.S)0.1ppm≤ 30 seconds
      ethylene oxide(ETO)0-100%LEL<±3%(F.S)1%LEL≤ 30 seconds
      Phosgene (COCL2)0-1ppm<±3%(F.S)0.001ppm≤ 20 seconds
      Phosgene (COCL2)0-50ppm<±3%(F.S)0.01ppm≤ 20 seconds
      Silane (SiH4)0-1ppm<±3%(F.S)0.001ppm≤ 30 seconds
      Silane (SiH4)0-50ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Fluorine (F2)0-1ppm<±3%(F.S)0.001ppm≤ 30 seconds
      Fluorine (F2)0-10ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Fluorine (F2)0-50ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Hydrogen fluoride (HF)0-10ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Hydrogen fluoride (HF)0-50ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Hydrogen bromide (HBr)0-50ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Ethylborane (B2H6)0-10ppm<±3%(F.S)0.001ppm≤ 30 seconds
      Hydrogen arsenide (AsH3)0-1ppm<±3%(F.S)0.001ppm≤ 30 seconds
      Hydrogen arsenide (AsH3)0-10ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Hydrogen arsenide (AsH3)0-50ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Germanane (GeH4)0-2ppm<±3%(F.S)0.001ppm≤ 30 seconds
      Germanane (GeH4)0-20ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Hydrazine, hydrazine (N2H4)0-1ppm<±3%(F.S)0.001ppm≤ 30 seconds
      Hydrazine, hydrazine (N2H4)0-300ppm<±3%(F.S)0.1ppm≤ 30 seconds
      Tetrahydrothiophene (THT)0-100mg/m3<±3%(F.S)0.01mg/m3≤ 60 seconds
      Bromine gas (Br2)0-10ppm<±3%(F.S)0.001ppm≤ 30 seconds
      Bromine gas (Br2)0-100ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Bromine gas (Br2)0-2000ppm<±3%(F.S)1ppm≤ 30 seconds
      Acetylene (C2H2)0-100%LEL<±3%(F.S)0.1%LEL≤ 30 seconds
      Acetylene (C2H2)0-100ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Acetylene (C2H2)0-1000ppm<±3%(F.S)0.1ppm≤ 30 seconds
      Ethylene (C2H4)0-100%LEL<±3%(F.S)0.1%LEL≤ 30 seconds
      Ethylene (C2H4)0-100ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Ethylene (C2H4)0-2000ppm<±3%(F.S)0.1ppm≤ 30 seconds
      acetaldehyde0-10ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Ethanol (C2H6O)0-100ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Ethanol (C2H6O)0-2000ppm<±3%(F.S)1ppm≤ 30 seconds
      Methanol (CH6O)0-100ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Methanol (CH6O)0-2000ppm<±3%(F.S)1ppm≤ 30 seconds
      Carbon disulfide (CS2)0-50ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Carbon disulfide (CS2)0-5000ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Acrylonitrile (C3H3N)0-50ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Acrylonitrile (C3H3N)0-2000ppm<±3%(F.S)1ppm≤ 30 seconds
      Methylamine (CH5N)0-50ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Classical Qi (I2)0-50ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Styrene (C8H8)0-200ppm<±3%(F.S)0.1ppm≤ 30 seconds
      Styrene (C8H8)0-5000ppm<±3%(F.S)1ppm≤ 30 seconds
      Vinyl chloride (C2H3CL)0-100ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Trichloroethylene (C2HCL3)0-100ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Perchloroethylene (C2CL4)0-100ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Laughing Gas (N2O)0-100ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Nitrogen trifluoride (NF3)0-100ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Hydrogen peroxide (H2O2)0-100ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Methyl bromide (CH3Br)0-100ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Methyl bromide (CH3Br)0-30000ppm<±3%(F.S)1ppm≤ 30 seconds
      Methyl bromide (CH3Br)0-200g/m3<±3%(F.S)0.1g/m3≤ 30 seconds
      Sulfuryl fluoride (SO2F2)0-100ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Sulfuryl fluoride (SO2F2)0-5000ppm<±3%(F.S)1ppm≤ 30 seconds
      Sulfuryl fluoride (SO2F2)0-10000ppm<±3%(F.S)1ppm≤ 30 seconds
      Benzene (C6H6)0-10ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Benzene (C6H6)0-100ppm<±3%(F.S)0.01ppm≤ 30 seconds
      Benzene (C6H6)0-2000ppm<±3%(F.S)1ppm≤ 30 seconds


      VS

      Skyeaglee SK/MIC-800-F2-Y/10000 Portable fluorine DetectorSpecifications

      LIST VALUE
      Detection gas Fluorine F2
      range 0~10000ppm
      Resolution 0.1ppm
      Sensors principle electrochemistry
      Operating Mode Pump suction
      Sampling Accuracy ≦3%F.S
      Sexual repeability 3%F.S
      Long term drift ≤±3% (F.S/年)
      Response time ≤10S
      Warm-up period 30S
      Operating Current ≤50mA
      data storage USB data collection, 300,000 group information storage
      service life 3 years
      Operating Pressure 86kpa-106kpa
      Shell material Anti-corrosion plastic, aluminum alloy
      Operating temperature -30~50℃
      Environment humidity 10~95% RH non-condensing
      Storage temperature -30~70℃
      Dimensions 228 * 84 * 50.5mm excluding sampling tube
      Weight 1.5kg
      Explosion-proof sign Exia II CT4

      Skyeaglee SK/MIC-800-F2-Y/10000 Portable fluorine Detector Packing list

      Portable detector X1, sampling tube X1, certificate X1, detector manual X1, charger X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Is the price listed on the website the final cost for overseas purchases?
      [A]
      No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
      [Q]
      What is the specific process for purchasing the product?
      [A]
      First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
      [Q]
      What should I do if the instrument I purchase needs repair?
      [A]
      After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
      +Skyeaglee SK/MIC-800-F2-Y/10000 Portable fluorine Detector Big data
        +Skyeaglee SK/MIC-800-F2-Y/10000 Portable fluorine DetectorStandard
        +Navigation
        Skyeaglee
        SK/MIC-800-F2-Y/10000 Portable fluorine Gas Detector, fluorine gas F2 electrochemistry 10000ppm
        Service
        Focus on online sales of Lab Testing Instruments