Bante PE-10 dual channel pen instrument pH conductivity temperature
At the same time pH, conductivity value, support 1~ 3 point calibrating, automatic temperature compensation, automatic identification of standard solution, PH Measurement range 0.00~14.00pH, PH Measurement accuracy +/- 0.05pH.
Bante-
Bante904P-UK portable multiparameter Water Quality Meter conductivity dissolved oxygen
$ 612.00 -
JINGQI WD8105 Cyanide Tester
$ 485.00 -
HANNA HI93700-01 Photometer reagent, low concentration ammonia nitrogen 100 times
$ 206.00 -
JINGQI WD9301B Portable Water Quality Tester
$ 1702.00 -
COD standard solution 1500mg/L, 250mL suitable for COD-571, DGB-401
$ 106.00
Measurement parameters
• pH, conductivity, temperature
pH Unit Functional Characteristics
• 2-point key calibration, automatic identification of pH standard buffer
• Key data lock, immediately retain the current measurement value
• Automatic power off, effectively saving battery power consumption
• Replaceable electrodes, reducing instrument maintenance and use costs
EC unit functional characteristics
• Multi-range conductivity meter
• 1 to 3 point calibration, automatic recognition of conductivity standard solution
• Automatic temperature compensation to ensure accurate measurement of the full scale range
• Automatic end point lock, keep stable readings for easy viewing and recording
• Setting menu can customize the number of calibration points, temperature unit, automatic shutdown, etc.
• Reset function, automatically restores to factory default settings
Bante PE-10 Dual channel pen instrumentSpecifications
| LIST | VALUE |
|---|---|
| PH range | 0.00~14.00pH |
| PH measurement Accuracy | ±0.05pH |
| Conductivity Detector display resolution | 0.01pH |
| Conductivity Detector Measurement range | 0~20.00, 200.0, 2000µS/cm, 20.00mS/cm |
| Conductivity Detector display resolution | 0.01,0.1,1 |
| Conductivity Detector calibrated point | 1 to 3 point |
| Conductivity Detector measurement Accuracy | Full scale ± 1% |
| Temperature Measurement range | PH: Measurement range EC: 0~60 ℃/32~ 140 ° F |
| Temperature measurement Accuracy | ±1°C/±1.8°F |
| Temperature offset calibrated | 1 point, measurement ± 10 ℃ |
Bante PE-10 Dual channel pen instrument Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 8884-2017
- ActiveJJF 1565-2016
- ActiveJJG 2059-2014
- ActiveHJ 1147-2020
- ActiveGB/T 6920-1986
- ActiveGB/T 13580.4-1992
- AbolishGB/T 1601-1993
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 2390-2013
- ActiveGB/T 3780.7-2016
- ActiveGB/T 14518-1993
- ActiveGB/T 35464-2017
- ActiveISO 19396-2-2017
- ActiveISO 19396-1-2017
- ActiveGB/T 41166-2021
- ActiveGB/T 5541-2017
- ActiveGB/T 34676-2017
- ActiveGB/T 21894-2008
- ActiveGB/T 7044-2022


PE-10