      Home> Conductivity Meter> Bante> Bante DDB-3 Portable Conductivity Meter

      Bante DB2-3 economical Chinese screen Portable Conductivity Meter conductivity temperature

      Measurement accuracy: 0.01µS/cm~ 20.00mS/cm. Conductivity Detector standard solution, automatic temperature compensation and electrode diagnosis. Measurement accuracy +/- 0.5%.

      Brand
      SKU: NB037171
      China Bante
      Model
      Stock
      Loading…
      Price
      $ 274.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • Bante DDB-3 Portable Conductivity MeterOverview

        • Specifications
        • Comments
        • FAQs
        DDB-3
        Portable Conductivity Meter
        • Bante DB2-3 economical Chinese screen Portable Conductivity Meter conductivity temperature
        • Bante DB2-3 economical Chinese screen Portable Conductivity Meter conductivity temperature Figure 1
        • Bante DB2-3 economical Chinese screen Portable Conductivity Meter conductivity temperature Figure 2
        Measurement accuracy: 0.01µS/cm~ 20.00mS/cm. Conductivity Detector standard solution, automatic temperature compensation and electrode diagnosis. Measurement accuracy +/- 0.5%.

        Measurement parameters

        • conductivity, temperature

        Features

        • 1 to 3 point calibration

        • Chinese screen tips

        • Automatic identification of conductivity standard solution

        • Automatic electrode diagnosis, with calibration point and conductivity cell coefficient display

        • Selectable cell constant, reference temperature, linear/nonlinear/pure water compensation mode

        • Automatic temperature compensation to ensure accurate measurement of the full scale range

        • Automatic end point lock, keep stable readings for easy viewing and recording

        • Setting menu can customize the number of calibration points, temperature unit, automatic shutdown, etc.

        • Reset function, automatically restores the instrument to factory default settings

        • Extended memory, store or recall up to 100 sets of data

        • USB communication interface, easy to transfer data or connect the power adapter to the meter


        VS

        Bante DDB-3 Portable Conductivity MeterSpecifications

        LIST VALUE
        Measurement range 0.01~20.00, 200.0, 2000µS/cm;20.00, 200.0mS/cm
        Conductivity calibrating point 1 to 3 point
        Conductivity calibrating fluid 0µS/cm,  84µS/cm, 1413µS/cm, 12.88mS/cm,    111.8mS/cm
        Temperature Measurement Range 0~105℃
        Temperature Display resolution 0.1℃/0.1℉
        Temperature measurement Accuracy ±0.5℃
        Temperature offset calibrated 1 point, Measured value +/- 10 ℃
        Temperature compensation range 0~100℃
        Temperature compensation coefficient Linear (0.0~10.0%/℃), nonlinear, pure water
        Conductivity Detector cell constant K=0.1,  1, 10
        data lock Manual or automatic end point locking
        Automatic shutdown After 30 minutes of no button operation
        Data storage 100 groups
        Interface USB
        Connector 6-Pin DIN
        Operating temperature 0~50℃
        Display Customized LCD (80 × 60mm)
        Power supply type AA type battery 3 or DC5V power adapter
        Battery life About 150 hours of continuous use (turn off the backlight)
        Dimensions 170*85*30mm
        Weight 300g
        Temperature compensation method Manual/Automatic

        Bante DDB-3 Portable Conductivity Meter Packing list

        host X1, manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Is the price listed on the website the final cost for overseas purchases?
        [A]
        No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
        [Q]
        What is the specific process for purchasing the product?
        [A]
        First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
        [Q]
        What should I do if the instrument I purchase needs repair?
        [A]
        After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
        Bante
        Bante DB2-3 economical Chinese screen Portable Conductivity Meter conductivity temperature
        Service
        Focus on online sales of Lab Testing Instruments