MODERNER XD-5RVOC-AHF walk-in VOC emission detection environmental Test Chamber
Walk-in VOC emission detection environmental test cabin simulates the reduction of parameters such as temperature, Humidity, number of ventilation and surface air Flow velocity of the sample in the natural environment, detects the VOC emission of the sample in practical applications, and evaluates the environmental protection evaluation standard
Moderner-
HYV-1000 1 cubic meter VOC emission environment Test Chamber
Login -
HYQC-1500 1.5 cubic meters environment Test Chamber Glass
Login -
HUANGYI HYQ-1000L 1 cubic meter formaldehyde release environment Test Chamber
Login -
Ring instrument HYV-60-6 VOC equilibrating chamber 6 barrel type
Login -
Ring instrument HYV-60-4 VOC equilibrating chamber 4 barrel type
Login
Overview
The walk-in VOC release detection environmental Test Chamber restores parameters such as temperature, humidity, ventilation , and detects actual conditions through the test methods and verification methods specified in the standard. The VOC release amount of the sample in volatilethe application , thereby The evaluation analyzes the various levels of quantification of the samples at the R&D and use levels and the analytical basis for the environmental impact assessment:
â Determine the impact of environmental variables on the VOC release amount and release characteristics of test materials
â Classify materials according to their VOC release characteristics
â Research and development of sample materials and verification of indoor air VOC release pollution characteristics
â The time duration at which the VOC release amount of the sample material decays in the natural environment
â Based on the detection data analysis, the assessment of indoor air quality will be predicted.

This climate cabin starts with one click and operates fully automatically. Temperature and Relative Humidity control uses PLC as the core control unit, which has high reliability and strong anti-interference ability. It realizes intelligent control of temperature and humidity. The temperature of the climate chamber is maintained at a constant temperature of 23℃ and a Relative Humidity of 50%. The air is replaced by pressurized pumps. Mode.
Equipment requirements
| Equipment requirements | |
| power supply | â Power supply: AC 380V 50Hz |
| â¡ Maximum load capacity: 12.5KW | |
| ⢠Maximum current: 18.5A | |
| ⣠Power switch capacity: 40A | |
| water supply | Please use pure water or distilled water, conductivity â¤10us/cm |
| Condensation drainage | The diameter of the drainage pipe is â¥DN32, the inclination angle is >5°, and the height difference below the drainage outlet is not less than 5cm. |
| Move-in conditions | |
| When moving parts and components into this laboratory, please meet the conditions on the right | Height of path passage and door: more than 3000mm |
| Width of path passage and door: more than 3000mm | |
| When using an elevator; in addition to meeting the above dimensions, the following requirements must also be met | |
| Depth: more than 3000mm; load capacity: more than 2000Kg | |
| â»If you cannot meet the above conditions, please be sure to contact us in advance. | |
â»Optional items for users
Purification device

| model | XD-5KQ-HT02 |
| air flow | ï¼15m³/h |
| Air supply pressure | 0.1ï½0.24bar |
| Air supply temperature | RT (normal temperature) |
| Formaldehyde mass concentration | â¤Â±0.001mg/m³ |
| VOC concentration | TVOCâ¤0.01mg/m³, single VOCâ¤0.001mg/m³ |
| noise | â¤60db (A sound level) |
Moderner XD-5RVOC-AHF VOC environment ChamberSpecifications
| LIST | VALUE |
|---|---|
| Interior size | Inner box size 5 +/- 0.02 m ³; width 1600mm depth 1600mm height 2000mm |
| Temperature & Moisture | Temperature range: 20 ℃~ 65 ℃; humidity range: 30%~ 75% RH (at + 20~ + 60 ℃) |
| Instrument resolution | Temperature: 0.1 ℃; Humidity: 0.1% RH; |
| Temperature Fluctuation | ±0.2℃; |
| Temperature Uniformity | ≤1.5℃ |
| Humidity stability | ≤±1.5%RH |
| air displacement rate | 1~ 3 times/hour (adjustable) |
| Flow rate Accuracy | Digital Flow rate meter, Accuracy class 0.5; 4-40m ³/L |
| Air tightness | When the pressure is over 1000pa, the leakage is less than 10- 3 × 1m 3/min. |
| Stabilization time | Temperature Stabilization time is less than 40min, Humidity Stabilization time is less than 60min, and the equipment can run continuously for not less than 30 days; |
| background indicator | TVOC≤0.05 mg/mm³ |
| noise | ≤ 60 decibels (A sound level), there will be no resonance sound between the box door and the equipment door |
Moderner XD-5RVOC-AHF VOC environment Chamber Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJG 1172-2007
- ActiveJG/T 481-2015
- ActiveJG/T 527-2017
- ActiveSN/T 3026-2011
- ActiveLY/T 1982-2011
- ActiveLY/T 1981-2011
- ActiveLY/T 1612-2004
- ActiveGB/T 43353-2023
- ActiveGB/T 33043-2016
- ActiveGB/T 38597-2020
- ActiveISO 3251-2019
- ActiveASTM D 3960-2018


XD-5RVOC-AHF