MODERNER XDWR-1-3FA architectural coatings Temperature Test Chamber
XDWR-1-3FA architectural coatings temperature resistance Test Chamber conforms to JG/T25-2017 "architectural coatings coating resistance to freezing-thaw cycle test method" standard. Three temperature control zones are used to evaluate whether the test plate coating has chalking, cracking, flaking, blistering, discoloration and other phenomena.
Moderner-
IPRE XY3020Q image Measurement Instrument, stroke 300mm
$ 8823.00 -
IPRE XY4030Q image Measurement Instrument, stroke 400mm
$ 9795.00 -
IPRE SC3020 one-button image Measurement Instrument, measuring range 300mm
$ 16596.00 -
IPRE SC1008 One-button fast imager, measuring range 100mm
$ 13002.00 -
IPRE PRINCE775 3D scanner, ultra-fine scanning
$ 40692.00
This equipment has three temperature control areas, namely constant temperature water control box, low temperature control box and high temperature control box. The equipment hanging basket places the samples into three environmental chambers respectively, and cycles them a specified number of times to evaluate whether the test plate coating has any phenomena such as powdering, cracking, peeling, blistering, or discoloration. It complies with the JG/T25-2017 "Method for Determination of Freeze-Thaw Cycle Resistance of Architectural Coatings" standard.
| Equipment requirements | |
| power supply | â Power supply: AC380V 50Hz |
| â¡ Large load capacity: 10KW | |
| ⢠Large current: 30A | |
| ⣠Power switch capacity: 32A | |
| give water | Please use pure water or distilled water, conductivity â¤10μS/cm2 |
| Move-in conditions | |
| When moving in the parts and components of this laboratory, | Height of path passage and door: more than 1200mm |
| Width of path passage and door: 1900mm or more | |
| Please meet the conditions on the right | When using an elevator; in addition to meeting the above dimensions, the following requirements must also be met |
| Depth: more than 2300mm; load capacity: more than 1000Kg | |
| â»If you cannot meet the above conditions, please be sure to contact our company in advance. | |
Moderner XDWR-1-3FA Thermal resistance Test Chamber for architectural coatingsSpecifications
| LIST | VALUE |
|---|---|
| exterior size | 2600 × 1100 × 1860mm (approx.) |
| Instrument resolution | Temperature: 0.1 ℃ |
| Temperature range | 1, thermostatic water: 23 +/- 5 ℃, 2, low temperature box: -25~ 20 ℃, 3, high temperature box: room temperature~ 70 ℃ |
| Temperature Fluctuation | ±1℃ |
| Temperature Uniformity | ≤2℃ |
| air displacement rate | 0.5~ 3 times/hour (adjustable) |
| Stabilization time | Stabilization time less than 40min |
| noise | Less than or equal to 75 decibels, there will be no resonance sound between the box door and the equipment door |
Moderner XDWR-1-3FA Thermal resistance Test Chamber for architectural coatings Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


XDWR-1-3FA