Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Surface Tensiometer> FangRui> FangRui BZY100 Surface TensioMeter
      FangRui BZY100 Surface TensioMeter

      FANGRUI BZY100 automatic Surface Tensiometer interfacial tension instrument, both plate/ring

      Test range 0~1000mN/m, platinum plate method, platinum ring method, 4.3-inch touch screen, high sensitivity, high precision, high repeability Sensors, automatic measurement, no need to calculate, directly display surface tension value or interfacial tension value, real-time display measurement Linear dispersion

      Brand
      SKU: NB038521
      China FangRui
      Stock
      Loading…
      Price
      $ 1731.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • FangRui BZY100 Surface TensioMeterOverview

        • Specifications
        • Comments
        • FAQs
        BZY100
        Surface TensioMeter
        • FANGRUI BZY100 automatic Surface Tensiometer interfacial tension instrument, both plate/ring
        Test range 0~1000mN/m, platinum plate method, platinum ring method, 4.3-inch touch screen, high sensitivity, high precision, high repeability Sensors, automatic measurement, no need to calculate, directly display surface tension value or interfacial tension value, real-time display measurement Linear dispersion


        BZY100&BZY200 Surface Tensiometer is widely used in the quality control process related to surface interfacial tension, such as emulsifier or wetting agent and cleaning agent detection. It has the characteristics of reliable performance, easy to use, independent of computers and other equipment, and can provide accurate and reliable analysis in the case of a large number of sample testing requirements. BZY100&BZY200 is controlled by automatic motor to realize fast switching of precise surface and interfacial tension measurement.

        Features

        1. Using 4.3-inch touch screen, all operations and information are completed or displayed on the screen;

        2. The sensor adopts the principle of electromagnetic force balance, with high sensitivity, high precision and high repetition;

        3. Both platinum plate method and platinum ring method are used;

        4. Fully automatic measurement, without calculation, directly display the surface tension value or interfacial tension value;

        5. One-key reset, one-key correction; digital processing technology, no deviation;

        6. Users can use standard samples (distilled water and pure ethanol) to calibrate the data to ensure the accuracy of the measurement;

        7. Display measurement curves in real time, save measurement results, print main parameters, data and curves;

        8. Double-door transparent plexiglass Wind Shield, easy to operate and reduce the use of environmental requirements;

        9. Password management function to ensure data traceability and prevent data modification and accidental deletion;

        10. Chinese/English interchange operation

        Standards

        We attach great importance to the repeatability and standardization of measurement results. The design of BZY100&BZY200 complies with all GB/T, EU, ISO, DIN specifications and ASTM standards on surface and interfacial tension.

        ASTM D971 Standard Test Method for Interfacial Tension of Oil-Water by Ring Method

        ASTM D1331 Standard Test Method for Surface and Interfacial Tension of Surfactant Solutions

        ASTM D1417 Standard Method for Testing Synthetic Rubber Latex

        DIN EN 14210 Surfactants - Determination of interfacial tension of surfactant solutions by the stirrup or suspension ring method

        DIN EN 14370 Surfactants - Determination of surface tension

        ISO 304 Surfactants - Determination of surface tension by the pulling film method

        ISO 1409 Plastics/rubber — Polymer dispersions and rubber latexes (natural and synthetic) — Determination of surface tension by the ring method

        ISO 4311 Anionic and nonionic surfactants — Determination of critical micelle concentration — Method for determination of surface tension using a hanging plate, stirrup ring or ring

        OECD 115 OECD Guidelines for Testing Chemicals: Surface Tension of Aqueous Solutions

        ISO 6889 Surfactants - Determination of surface tension by the pulling film method

        GB/T 22237-2008 Determination of Surface Tension of Surfactants  

        JB/T 9388 -2002 Technical Conditions for Interfacial Tensiometer  

        JB/T 18396-2001 Determination of surface tension by natural latex ring method  

        SH/T 1156-95 Determination of surface tension of synthetic latex  

        GB/T 6541 - 86 Determination of interfacial tension between oil and water of petroleum products (ring method)  

        ISO 1409-1995 Determination of surface tension of plastics, rubber, polymer dispersions and latex

        ISO 6295-1983 Determination of interfacial tension of petroleum products, mineral oil and oil on water (ring method)  

        GB/T 5549 (ISO304-1985) Determination of Surface Tension by Pull-up Film Method  

        GB 15308-2006 Foam fire extinguishing agent

        GBT 11276-2007 Determination of Critical Micelle Concentration of Surfactants

        GB-T 22237-2008 Determination of Surface Tension of Surfactants

        Operation interface

        FANGRUI BZY100 Surface Tensiometer Details Figure 1

        FANGRUI BZY100 Surface Tensiometer Details Figure 2

        FANGRUI BZY100 Surface Tensiometer Details Figure 3

        Application

        Part of application
        ink, inkAnalysis of printing/coating tendency, wetting, quality control
        detergentAnalyze the absorption speed and properties of surfactants, and study the appropriate concentration
        Chemical aidAbility to Study Aggregation and Diffusion Behavior
        cosmeticAnalyze the dispersion, stability and wettability of emulsions or suspensions
        platingAnalyze wettability for quality control
        Pesticides, traditional Chinese medicineAnalysis of adsorption, dispersion, stability and other capabilities
        paintAnalysis of dispersion, stability, wetting, etc.
        Petroleum product oil such as transformer oilThe value of oil-water interfacial tension is closely related to the purity of new oil and the deterioration of operating oil
        water treatmentSewage treatment, water quality analysis



        VS

        FangRui BZY100 Surface TensioMeterSpecifications

        LIST VALUE
        Measurement method Platinum plate method, platinum ring method
        Surface tension Measurement range 0~1000mN/m
        Surface tension Accuracy 0.1mN/m
        Operation mode Automatic lifting, automatic measurement
        Display 4.3-Inch touch screen, direct data reading
        Measurement time Within 60 seconds
        Data Interface RS232 (printer optional)
        Dimensions 280*200*360mm
        Net Weight 8kg
        Power 110V或220V、30W

        FangRui BZY100 Surface TensioMeter Packing list

        Host X1, calibrated weight X1, extension hook X2, platinum plate X1, platinum ring X1, Glass ware X2, forceps X1, alcoholburner X1, power cord X1, operation manual X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        We do cosmetics research and development, need to analyze the dispersion and Stability of emulsion, which instrument should choose?
        [A]
        The BZY100 surface tensiometer uses the platinum plate method and the platinum ring method to accurately measure surface tension, help evaluate the dispersion, Stability and wettability of cosmetics, and meets many international standards to ensure reliable data.
        [Q]
        I need a fully functional instrument that can automatically measure surface tension. What do you recommend?
        [A]
        BZY100 surface tensiometer automatic measurement, direct display results, no manual calculation, and Touchscreen operation, support one-button calibrate and Linear dispersion display, complete functions, very convenient to use.
        [Q]
        Does the surface tensiometer say how much capacity is required?
        [A]
        This type of surface tension detector, plate method measurement of at least 7mL sample, ring method measurement of 15mL.
        [Q]
        Data analysis and result processing?
        [A]
        Equipped with data collection and analysis software, the instrument can display measurement data in real time and provide Linear dispersion fitting, result calculation and data export functions.
        [Q]
        How to avoid external interference in the measurement process of automatic surface tensiometer?
        [A]
        Measurement parameters and instrument settings can be selected to reduce the impact of external vibration and environment changes through appropriate operating environment and protective measures.
        FangRui
        FANGRUI BZY100 automatic Surface Tensiometer interfacial tension instrument, both plate/ring
        Service
        Focus on online sales of Lab Testing Instruments