SMART SENSOR AR8406 Dissolved Oxygen Meter dissolved oxygen measurement meter split Dissolved Oxygen Meter
AR8406 dissolved oxygen instrument dissolved oxygen measurement range 0.0~30.0 mg/L (mg/L), dissolved oxygen resolution 0.1mg/L, dissolved oxygen accuracy +/- 3.0% full scale, LCD large screen display, automatic temperature compensation
SMART SENSOR-
YUEFENG SZ8112 copper analyzer, copper content analyzer 0~ 2.0mg/L
$ 343.00 -
YUEFENG SZ8116 iron analyzer, iron content analyzer 0~ 0.8mg/L
$ 343.00 -
DDKSIC DO100 laboratory Dissolved Oxygen Meter (polarographic type) dissolved oxygen concentration/dissolved oxygen saturation/℃
$ 570.00 -
HANNA HI97105 multiparameter photometer for seawater
$ 652.00 -
Bante904-CN Precision pH/conductivity /TDS/salinity/resistivity meter
$ 590.00
Key Function

SET key: Short press to switch on/off/long press to enter the setting mode
CAL/ESC key: long press in measurement mode to enter calibration mode / short press in setting mode to exit setting mode
Recall key: short press to turn on or off the backlight / long press to view the saved data, press the up and down keys to view the recorded data one by one, press the ESC key to exit the record viewing mode.
Mode/▲ key: increase value/switch mode
Save/▼ key: Short press to decrease value/switch mode/measurement mode to save data manually (up to 99 items)
Enter key: confirmation key
Measurement methods
Put the measuring rod head to the depth of the water layer to be measured (the measuring rod head cannot touch the bottom of the pool), and keep swinging the measuring rod back and forth or left and right (if you do not swing the measuring rod, the measured value will continue to drop, lower than the actual dissolved oxygen value), after 1 to 3 minutes, the temperature of the measuring rod and the temperature of the water layer to be measured reach equilibrium, and the measurement data can be recorded. For seawater occasions or plateau areas, salinity .
SMART SENSOR AR8406 Dissolved Oxygen MeterSpecifications
| LIST | VALUE |
|---|---|
| DO Measurement Range | 0.0~30.0mg/L |
| DOS resolution | 0.1mg/L |
| DO measurement Accuracy | ±3.0%FS |
| DO correction | 100% saturated oxygen in the air |
| Temperature Measurement Range | -5℃~60℃ |
| Temperature Resolution | 0.1℃ |
| Automatic shutdown | Automatic shutdown after one hour of no operation |
| Temperature unit | ℃/° F switching |
| screen display | LCD large screen display |
| Automatic temperature compensation ATC | support |
| Altitude compensation | 0~3500m |
| Probe line length | About 3.5 meters (plus probe) |
SMART SENSOR AR8406 Dissolved Oxygen Meter Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 1714-2018
- ActiveJJF 1565-2016
- ActiveJJF 1441-2013
- ActiveJJG 2104-2024
- ActiveCJ/T 139-2001
- ActiveHJ 925-2017
- Active 096-2007
- ActiveSC/T 7006-2001
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveGB/T 1576-2018


AR8406