Smart Sensor PH818 Pen pH Detector
PH818 pen PH Detector measuring range 0.00~14.00ph, measurement intrinsic error ± 0.05ph, instrument, sexual repeability ± 0.03ph, dissolved oxygen temperature compensation range 0 ℃~ 70 ℃, temperature accuracy ± 1 ℃, measured solution temperature 0 ℃~ 60 ℃
SMART SENSOR-
LEICI T-818-B-6F type temperature electrode BNC (Q6 waterproof type)
$ 127.00 -
Kodida CT-6658 PH/ORP Controller, Electrodeless Range: 0.00~14.00pH
$ 222.00 -
LEICI E-201F pH Fillable Composite electrode
$ 87.00 -
LANDTEK PH/ORP-2000 acid alkalinity controller, acid alkalinity and oxidation-reduction potential dual-use
$ 206.00 -
Smart Sensor PH818 Pen pH Detector
$ 103.00
The portable pH Detector produced by our company has high precision , stable, reliable and easy to carry. The appearance design is novel and beautiful, and the product design is more professional. It can measure the pH value of the solution and display the temperature of the measured liquid. PH Tester is widely used in fields such as industry, electric power, agriculture, medicine, food, scientific research and environmental protection.
Instrument structure

①Power switch/data hold key
②Calibration/value increase key
③Backlight / Numerical decrease key
④PH value display area
⑤Temperature display area
⑥ Probe

SMART SENSOR PH818 Pen pH MeterSpecifications
| LIST | VALUE |
|---|---|
| PH range | 0.00~14.00ph |
| Measurement intrinsic error | ±0.05ph |
| Instrument, repeability | ±0.03ph |
| Dissolved oxygen temperature compensation range | 0℃~70℃ |
| temperature Accuracy | ±1℃ |
| Measured solution temperature | 0℃~60℃ |
| resolution | 0.01ph |
| data retention | Yes. |
| screen display | LCD large screen display |
| ℃/° F temperature unit conversion | Yes. |
| Automatic shutdown function | Yes. |
| Self-calibrating function | Yes. |
SMART SENSOR PH818 Pen pH Meter Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 3324-2024
- ActiveGB/T 2394-2024
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveSN/T 1523-2005
- ActiveQB/T 2724-2018
- ActiveJB/T 6203-2017
- ActiveNY/T 82.7-1988
- Active 098-2007
- ActiveGB/T 1601-2023
- ActiveGB/T 18920-2020
- ActiveGB/T 6920-1986
- ActiveGB/T 13580.4-1992
- AbolishGB/T 1601-1993
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 2390-2013
- ActiveGB/T 3780.7-2016
- ActiveGB/T 14518-1993


PH818