LEICI DZS-706F multiparameter analyzer
pH/pX level 0.01, conductivity level 1.0, test items: pH/pX value, Ion concentration, mV value, conductivity, Electrical resistivity, TDS, salinity, dissolved oxygen, dissolved oxygen saturation, temperature
LeiCi-
YUEFENG SZ8112 copper analyzer, copper content analyzer 0~ 2.0mg/L
$ 343.00 -
HANNA HI98192 Conductivity Meter EC/TDS/Electrical resistivity /NaCl/Temperature professional measurement
$ 1223.00 -
HANNA HI98130 acidity meter multiparameter pH-EC-TDS Measurement Instrument
$ 354.00 -
NOBOTECH PH-1186 Industrial Online ORP Meter-1999~ + 1999mV
$ 257.00 -
HANNA HI764080A/P special PTFE dissolved oxygen membrane
$ 214.00








main feature
â Adopt high-definition LCD with clear display
â Temperature units are optional: ℃ and °F.
âSupports functions such as power-on self-diagnosis, automatic shutdown, power-off protection and factory reset
â Support firmware upgrade function, allowing function expansion and personalized requirements
âSupport IP54 protection level
â Standard configuration of three-composite pH electrode, composite conductivity electrode, polarographic dissolved oxygen electrode, electrode holder, dust cover and calibration solution
One machine for multiple purposes
â Built-in 3 measuring units of pH/pX, conductivity and dissolved oxygen
â Test items: pH/pX value, ion concentration, mV value, conductivity, resistivity, TDS, salinity, dissolved oxygen, dissolved oxygen saturation, temperature
Intelligent detection and automatic identification
â Intelligent end point determination: supports automatic reading, scheduled reading, scheduled interval reading, and manual reading
âSupport automatic temperature compensation, automatic calibration, and electrode diagnosis
Data management, information traceability
â Support data storage (500 sets each), review, deletion, transmission and printing
â Comply with GLP and realize data traceability
â Equipped with RS-232 interface, supports connection to standard RS-232 serial port printer, and directly prints measurement results. The printing format is optional.
â With USB interface, it can be connected to PC through special communication software to realize data transmission.
pH/ion measurement function:
â Automatically identify multiple groups of buffer solutions such as GB, DIN, and NIST, and support customization of standard solutions and standard solution groups, with up to 5 points of calibration.
â Built-in Na+, K+, NH4+, Cl-, F- and other ion modes, allowing users to create their own
â Rapid switching of multiple ion concentration units such as μg/L, mg/L, g/L, mol/L, mmol/L, and PX
âMeasurement mode: direct reading concentration method measurement
Conductivity measurement function:
â Within the range, it has functions such as automatic temperature compensation and automatic range switching.
â Automatically identify conductivity standard solutions and support 1-3 point conductivity electrode calibration
âSupports multiple conductivity compensation methods such as non-compensation, linear, pure water compensation, etc.
â Reference temperature 20℃ or 25℃ optional
â Supports automatic frequency switching, and is equipped with a 1.0 constant electrode that can cover the full range of measurements (it is recommended to use a 0.1 constant or 0.01 constant conductivity electrode for measurement of samples below 20 μS/cm)
Dissolved oxygen measurement function:
âSupports automatic temperature compensation and automatic atmospheric pressure compensation (units optional: kPa, mbar, Torr, Atm)
â Support zero oxygen calibration and full scale calibration
âSupport manual salinity compensation function
LeiCi DZS-706F Multiparameter analyzerSpecifications
| LIST | VALUE |
|---|---|
| Conductivity level | Level 1.0 |
| mV resolution | 0.1mV |
| mV electronic unit intrinsic error | +/- 0.1% or +/- 0.3mV |
| mV Electronic Unit Repeatability | 0.5 mV |
| mV Electronic Unit Input Impedance | ≥1×1012Ω |
| pH Measurement Range | -2.00~20.00pH |
| An indication of pH electronic unit error | ±0.01pH |
| Repeatability of pH electronic unit | 0.005pH |
| An indication of pH instrument error | ±0.02pH |
| pH Instrument Repeatability | 0.01pH |
| pX Measurement Range | (-2.00~20.00)pX |
| pX resolution | 0.01pX |
| PX electronic unit error of indication | ±0.01pX |
| pX Electronic Unit Repeatability | 0.005pX |
| PX instrument error of indication | ±0.02pX |
| pX Instrument Repeatability | 0.01pX |
| Ion concentration range | (0~1990), (UL, mmol/L, g/L, mg/L, μg/L |
| Ion resolution | 4 significant digits |
| Ionic electronic unit error of indication | ±0.5% |
| Ion conductivity range | 0.000 μS/cm~1000mS/cm |
| Ion conductivity minimum resolution | 0.001 μS/cm, automatic switching |
| Ion conductivity electronic unit reference error | ± 1.0%(FS) |
| Repeatability of ion conductivity electronic unit | 0.33%(FS) |
| Ion conductivity instrument reference error | ±1.50%(FS) |
| Repeatability of ion conductivity instrument | 0.50%(FS) |
| Electrical resistivity Measurement Range | 5.00Ω·cm~20.00MΩ·cm |
| Electrical resistivity resolution | 0.01 Ω · cm, automatic switching |
| Electrical resistivity electronic unit reference error | ±1.0%(FS) |
| TDS range | 0.00mg/L~300g/L |
| TDS resolution | 0.01Mg/L, automatic switching |
| TDS electronic unit reference error | ±1.0%FS |
| Salinity range | 0.00~8.00% |
| Salinity resolution | 0.01% |
| Salinity electronic unit reference error | ±0.2% |
| Reference error of salinity instrument | ±0.4% |
| DO Measurement Range | 0.00~20.00mg/L |
| DOS resolution | 0.01 mg/L |
| DO electronic unit error of indication | ±0.10mg/L |
| DO Zero Error | ≤0.1mg/L |
| DO response time | ≤ 45s (90% Response at 20.0 ℃) |
| DO error of indication | ±0.30mg/L |
| DO% Measurement Range | 0.0~200.0% |
| DO% resolution | 0.1% |
| DO% error of electronic unit indication | ±2.0% |
| Saturation instrument error of indication | ±10.0% |
| Temperature Measurement Range | -5.0~110.0℃ |
| Temperature Resolution | 0.1℃ |
| Temperature electronic unit error of indication | ±0.2 ℃ |
| Temperature instrument error of indication | +/- 0.4 ℃ (0.0 ℃ -60.0 ℃) +/- 1.0 ℃ (Miscellaneous range) |
| Operating Environment | Ambient Temperature: (0~40) ℃ Relative Humidity: not more than 85% |
| Dimensions | 242*195*68mm |
| Weight | About 0.9kg |
| Power | Power adapter (input: AC 100~240V output: DC 9 V) |
LeiCi DZS-706F Multiparameter analyzer Packing list
Host X1, E-301-QC type pH three, compound, electrode X1, DJS-1VTC type Conductivity detector electrode X1, DO-958-Q type dissolved Oxygen electrode X1, pH bagged buffer solution (3 * 10) X1, conductivity solution 1408μs/cm (1 * 10) X1, multifunctional electrode holder X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 693-2024
- ActiveGB/T 8884-2017
- ActiveJJF 1714-2018
- ActiveJJF 1565-2016
- ActiveJJG 2059-2014
- ActiveJJF 1441-2013
- ActiveJJG 2104-2024
- Active 126-2009
- ActiveHJ 1147-2020
- Active 096-2007
- ActiveSC/T 7006-2001
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveGB/T 1576-2018
- ActiveGB/T 17650.2-2021
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007
- ActiveGB/T 32697-2016


DZS-706F