      Home> Color Assessment Cabinet> EVERFINE> EVERFINE VCA-3300 Standard light source Color Assessment Cabinet

      EVERFINE VCA-3300 Standard light source Color Assessment Cabinet 7 Light source adjustable illumination

      7 Light source illuminance adjustable, equipped with 45 degree observatory, Light source types D65, CWF, TL84, U30, A, HZ, UV, no preheating, no flashing, no active heat dissipation, high luminous efficiency, fast and reliable evaluation of Color.

      Brand
      SKU: NB038951
      China EVERFINE
      Stock
      Loading…
      Price
      Please contact customer service
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • EVERFINE VCA-3300 Standard light source Color Assessment CabinetOverview

        • Specifications
        • Comments
        • FAQs
        VCA-3300
        Standard light source Color Assessment Cabinet
        • EVERFINE VCA-3300 Standard light source Color Assessment Cabinet 7 Light source adjustable illumination
        • EVERFINE VCA-3300 Standard light source Color Assessment Cabinet 7 Light source adjustable illumination Figure 1
        • EVERFINE VCA-3300 Standard light source Color Assessment Cabinet 7 Light source adjustable illumination Figure 2
        7 Light source illuminance adjustable, equipped with 45 degree observatory, Light source types D65, CWF, TL84, U30, A, HZ, UV, no preheating, no flashing, no active heat dissipation, high luminous efficiency, fast and reliable evaluation of Color.

        In textiles, plastics, coatings, dyes, consumer electronics, automobiles and many other industries that have very high color requirements, visual color inspection is an important part of color quality control. The color and gloss of products observed by people will change with the The illumination light source spectrum or illumination angle changes, so during visual evaluation, it is necessary to first determine the light source spectrum type, illumination angle, observation angle and other factors that affect the visual evaluation effect.

        VCA-3300 standard light source color matching light box adopts patented technology and internationally renowned brand light sources and intelligent controllers, combined with a uniform light device with excellent diffusion characteristics, to accurately match and accurately simulate D65, A, HZ, CWF, TL84, and U30 The light and color environment required by various standards such as , F, UV, etc. is designed in accordance with the requirements of ASTM, CIE, ISO, GB and other standards, providing a solid technical guarantee to improve the consistency and reliability of color comparison.

        Yuanfang VCA-3300 standard light source color matching light box details picture 1

        main feature

        • Configure a variety of commonly used standard light sources to accurately simulate various light source spectra;

        • D65 light source meets CIE Class A spectral matching requirements;

        • VCA-3300 has an illumination adjustment function to meet the color performance evaluation of the tested product under different lighting conditions;

        • Using Yuanfang's patented technology to achieve good diffuse reflection and uniform lighting standard environment;

        • UV light can be combined with any light source to detect and evaluate optical brighteners, fluorescent dyes and pigments;

        • Configure a safe and intelligent statistical controller to record and display the name, cumulative usage time, and cumulative number of switches of each light source;

        • No need for preheating, no flickering, no need for active heat dissipation, high luminous efficiency, and fast and reliable color evaluation.

        • Equipped with a 45-degree observation platform to achieve 45/0 observation conditions.

        • Larger space, suitable for color comparison of large items.

        Yuanfang VCA-3300 standard light source color matching light box details picture 2

        Light source type

        D65 light source: Correlated color temperature 6500K, LED combination light source; color rendering index 96 or above;

        CWF light source: Correlated color temperature 4150K, cool white fluorescent lamp; American commercial or office light source;

        TL84 light source: correlated color temperature 4000K, commercial fluorescent light source from Europe, Japan and CHINA;

        U30 light source: Correlated color temperature 3000K, warm white fluorescent lamp; American commercial light source;

        A light source: Correlated color temperature 2856K, warm color tungsten halogen lamp, simulated home, hotel, American window lighting;

        HZ light source: Correlated color temperature 2300K, Horizon, horizontal daylight;

        UV light source: LED combination light source;

        typical application

        Printing, textile, plastic rubber, automobile, consumer electronics, etc.



        VS

        EVERFINE VCA-3300 Standard light source Color Assessment CabinetSpecifications

        LIST VALUE
        Color of inner wall Munsell neutral grey
        Light source type D65、CWF、TL84、U30、A、HZ、UV
        cumulative opening time 1 minute to 1000 hours
        cumulative number of switches 1-65000 times
        Volume Weight 630mm*950mm*1000mm/75Kg
        Ambient Temperature 0-35℃
        Power 220V/50Hz,<2.5KW
        Observatory Equipped with a 45-degree observation station (referring to ISO 105 observation conditions)

        EVERFINE VCA-3300 Standard light source Color Assessment Cabinet Packing list

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Is the price listed on the website the final cost for overseas purchases?
        [A]
        No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
        [Q]
        What is the specific process for purchasing the product?
        [A]
        First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
        [Q]
        What should I do if the instrument I purchase needs repair?
        [A]
        After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
        EVERFINE
        EVERFINE VCA-3300 Standard light source Color Assessment Cabinet 7 Light source adjustable illumination
        Service
        Focus on online sales of Lab Testing Instruments