LEICI DDB-305A Portable Conductivity Meter 1.0 level conductivity TDS temperature value
Automatic identification conductivity standard solution, support 1 point calibrate, support electrode constant setting, 0.01, 0.1, 1.0, 10 four electrode constants optional; support 200 sets of Data storage, automatic determination of the end point.
LeiCi-
Bante531-S Portable Conductivity Meter for Routine Applications
$ 312.00 -
KODIDA 1413I/CMS Conductivity Detector 50ml
$ 86.00 -
LEICI DDS-11A Digital Display Conductivity Meter
$ 253.00 -
HANNA HI98304 high range conductivity EC Tester
$ 186.00 -
FANGZHOU FZ-705W Conductivity Detector electrode (platinum black) > 100mS/cm
$ 133.00






LeiCi DDB-305A Portable Conductivity MeterSpecifications
| LIST | VALUE |
|---|---|
| Instrument level | Level 1.0 |
| Measurement parameters | Conductivity, TDS, temperature |
| Conductivity range | 0.00μ S/cm~200mS/cm |
| Resolution | 0.01μS/cm, automatically switch according to the range |
| Electronic unit reference error | ± 1.0%F.S. |
| TDS range | 0.00 mg/L~100g/L |
| Resolution | 0.01Mg/L, automatically switched according to the range |
| Temperature Measurement Range | -5.0~110.0℃ |
| Resolution | 0.1℃ |
| Electronic unit error of indication | ±0.2 ℃ |
| Power | Rechargeable lithium battery, power adapter (input: AC100~240V, output: DC5V) |
| size | 80*225*35mm |
| Weight | 0.4kg |
LeiCi DDB-305A Portable Conductivity Meter Packing list
Host X1, DJS-1VTC Conductivity detector electrode X1, electrode hanger X1, protective cover X1, wristband assembly, part X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- How to test abrasives with a conductivity meter?
- The Working Principle of Gel Conductivity Meter Has Been Detailed
- How to use the new touch screen conductivity meter correctly? [Five and a half minutes video demonstration]
- Detection Principle and Application Analysis of Conductivity Meter
- Several common electrode types for Conductivity Meters
- ActiveJJG 2059-2014
- ActiveJB/T 9366-2017
- ActiveSL 78-1994
- ActiveGB/T 12582-1990
- ActiveGB/T 13580.3-1992
- ActiveGB/T 6539-1997
- ActiveGB/T 18932.15-2003
- ActiveGB/T 11007-2008
- ActiveGB/T 23977-2009
- ActiveGB/T 20245.3-2013
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007
- ActiveGB/T 32697-2016
- ActiveGB/T 33328-2016
- ActiveISO 21318-2007
- ActiveISO 8502-9-2020
- ActiveGB/T 27503-2011
- ActiveGB/T 27502-2011
- ActiveHG/T 3802-2005


DDB-305A