FANGZHOU FZ-863 PH Glass electrode with temperature probe, suitable for high temperature solution
With temperature probe, automatic temperature compensation, special PHY Glass film, silver ion trap reference system, anti-pollution PTFE liquid complex, suitable for high temperature and chemical corrosion solution, heavy pollution samples.
FZchina-
FANGZHOU PHS-430 high-precision module acidity meter 0.001 multiparameter can be connected to PC
$ 1117.00 -
FANGZHOU FZ-551 Soil pH electrode for soft or hard sample testing
$ 238.00 -
PH acidity meter AOLILONG PHB-2 Accuracy is +/- 0.02pH
$ 119.00 -
KEDIDA CT-6023 Pen type acidity meter with built-in electrode PH Range: 0.00~14.00PH
$ 116.00 -
HANNA HI98127 pH Measurement Instrument - 2.0~16.0pH
$ 288.00
pH Measurement and Electrode Selection - Strong Acids, Strong Bases and High Temperature Samples
In a strong acid solution with a pH value of less than 1, there will be an acid error, and the measured value is greater than the sample value; in a strong alkaline solution with a pH value greater than 10, there will be an alkali error, and the measured value will be smaller than the sample value; not only the measured value error, strong acid The strong alkali solution will also corrode the glass membrane, and the electrode will be damaged quickly, and the damage will be more serious at high temperature.
Application requirements for strong acid, strong base and high temperature measurement
Hydrofluoric acid resistant, strong alkali resistant, high temperature resistant glass film


Strong acid, strong alkali and high temperature measurement series ph electrode parameters
| FZ | 831 | 833 | 841 | 843 | 861 | 863 |
| pH range | 0-12pH | 0-12pH | 1-14pH | 1-14pH | 1-13pH | 1-13pH |
| temperature range | 0~100℃ | 0 ~100℃ | 0~130℃ | 0~130℃ | 0 ~130℃ | 0~130℃ |
| temperature probe | none | NTC 30KΩ | none | NTC 30KΩ | none | NTC 30KΩ |
| glass film | HF | HF | HA | HA | PHY | PHY |
| Membrane impedance | <400MΩ | <400MΩ | <500MΩ | <500MΩ | <500MΩ | <500MΩ |
| Junction | ceramic core | ceramic core | ceramic core | ceramic core | Porous PTFE | Porous PTFE |
| reference system | silver ion trap | silver ion trap | silver ion trap | silver ion trap | silver ion trap | silver ion trap |
| reference electrolyte | 3M KCL | 3M KCL | 3M KCL | 3M KCL | 3M KCL gel | 3M KCL gel |
| Shell material | lead-free glass | lead-free glass | lead-free glass | lead-free glass | lead-free glass | lead-free glass |
| electrode size | φ12*120mm | φ12*120mm | φ12*120mm | φ12*120mm | φ12*120mm | φ12*120mm |
| Interface/Cable | BNC/1m | BNC/1m | BNC/1m | BNC/1m | BNC/1m | BNC/1m |
FZchina FZ-863 PH electrodeSpecifications
| LIST | VALUE |
|---|---|
| Measurement parameters | PH value |
| PH range | 1~13pH |
| Temperature range | 0~130℃ |
| Temperature probe | NTC 30KΩ |
| Glass film | PHY |
| Membrane Impedance | <500MΩ |
| Liquid network department | Porous PTFE |
| reference type | silver ion trap |
| Reference electrolysis solution | 3M KCL Gel |
| Shell material | Lead Free Glass |
| Electrode size | Φ12*120mm |
| Connector | BNC/1m |
FZchina FZ-863 PH electrode Packing list
Electrode X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveGB/T 8077-2023
- ActiveGB/T 6920-1986
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 2390-2013
- ActiveGB/T 14518-1993
- ActiveISO 19396-2-2017
- ActiveISO 19396-1-2017
- ActiveQB/T 2724-2005


FZ-863
FZ-861
FZ-843
FZ-841
FZ-833
FZ-831